We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
Monitor power, voltage, energy, current and an expanse of other electrical parameters on a single and three-phase system with the PowerScout PS3037-S-N Power Submeter from DENT Instruments. DENT Instruments has introduced their new revenue-grade power meter as a replacement option for the PowerScout 3 Plus. One of four configurations in the PowerScout 3037 series, the PS3037-S-N is ideal for use that requires only serial communications.See the accessories tab for available DENY CTs.
This latest PowerScout offers a variety of new and innovative features, like the USB port, DIN Rail mounting option and the elimination of integral voltage leads, all at a lower cost.
TECHNICAL | |
Service Type | Single Phase, 3 Phase - 4 Wire (WYE), 3 Phase - 3 Wire (Delta) |
Power | From L1 Phase to L2 Phase. 80-600VAC CAT III 50/60Hz, 70mA Max. Non-user replaceable .5 Amp internal fuse protection |
Power Out | Unregulated 5VDC output, 140 mA Max, resetting fuse |
Voltage Channels | 80-346 Volts AC Line-to-Neutral, 600V Phase-to-Phase, CAT III |
Current Channels | 3 channels, 0.52 VAC max, 333 mV CTs, 0-4,000A |
Maximum Current Input | 158% of current transducer rating (mV CTs) to maintain accuracy. Measure up to 4000A with RoCoil CTs |
Measurement Type | True RMS using high-speed digital signal processing (DSP) |
Line Frequency | 50/60 Hz |
Waveform Sampling | 200 samples/60Hz waveform, 240 samples/50Hz waveform 2 waveforms/second |
Parameter Update Rate | 1 second |
Measurements | Volts, Amps, kW, kWh, kVAR, kVARh, kVA, kVAh, aPF, dPF. |
Accuracy | 0.2% (<0.1% typical) ANSI C12.20-2010 Class 0.2 |
Resolution | 0.01 Amp, 0.1 Volt, 0.01 watt, 0.01 VAR, 0.01 VA, 0.01 Power Factor depending on scalar setting |
LED Indicators | Bi-color LEDs (red and green): 1 LED to indicate communication, 3 LEDs for correct CT-to-phase installation (per meter element). |
Pulse Output | Open Collector, 5mA max current, 30V max open voltage |
COMMUNICATIONS | |
Direct | User selectable Modbus/BACnet Master Slave Token Passing protocol (MS/TP) or (optional) BACnet IP/Modbus TCP over Ethernet. |
MAX Distance | 1200 meters with Data Range of 100K bits/second or less |
Baud Rate | 9600 (Modbus default), 19200, 38400, 57600, 76800 (BACnet default), 115200 |
Data Bits | 8 |
Parity | None, Even, Odd |
Stop Bit | 2, 1 |
Data Formats | Modbus or BACnet |
MECHANICAL | |
Operating Temperature | -20° to 60°C (-4° to 140°F) |
Humidity | 5% to 95% non-condensing |
Enclosure | ABS Plastic, 94-V0 flammability rating |
Weight (Excluding CTs) | 340 g (12 ounces) |
Dimensions | 24.2 x 8.5 x 4.0 cm (9.5” x 3.3” x 1.6”) |
VIEWPOINT SOFTWARE | |
Operating System | Windows® 8, Windows® 7 (32/64 bit), Windows® Vista (32/64 bit), or Windows® XP |
Communications | RS-485 & USB standard. Ethernet available. One USB Port required on PC. |
SAFETY | |
UL Listed and CE Mark Conforms to UL Std 61010-1 Certified to CSA Std C22.2 No. 61010-1 |
- Retail
- Industry
- Data Center Monitoring
- Tenant Submetering
- Commercial
- Net Metering