We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
DENT Instrument’s ELITEpro XC series of wireless energy data loggers now features the EXCUN Energy Logger with Ethernet and USB Communications. The EXCUN measures, stores and analyzes electrical consumption data; a derivative from the current and voltage inputs. Using direct connections to each phase of the voltage and assorted interchangeable CT options, like split-core current transformers or RoCoils, the EXCUN monitors current on each phase. See the accessories tab for available DENT CTs. Now, the EXCUN ELITEpro XC comes equipped with 4 analog input channels which users can configure for either voltage or current input.
The energy logger has the capacity to capture kWh/kW energy and demand data in addition to nearly all pertinent energy parameters for diagnostics and monitoring on three-phase or single-phase circuit installations.
The EXCUN is explicitly configured with an Ethernet port and standard USB. In addition to connecting directly to the energy logger, the ELITEpro XC is capable of remote data downloads via a local area network.
* Supports 10/100 MB Ethernet over Cat 5 or better and can be configured for DHCP or static IP
TECHNICAL | |
Service Type | Single Phase (two wire or three wire), Three Phase-Four Wire (WYE), Three Phase-Three Wire (Delta), DC Systems (Solar/Battery) |
Voltage Channels | 3 channels, CAT III, 0-600 VAC (line-to-line) or 600 VDC* |
Current Channels | 4 channels, .67 VAC max, +/- 1 VDC. Ideal for 333 mV full scale CTs |
Maximum Current Input | External transducer dependent. 200% of current transducer rating (mV CTs) Measure up to 6000A with RoCoil CTs. |
Measurement Type | True RMS using high-speed digital signal processing (DSP) |
Line Frequency | DC/50/60 Hz* |
Waveform Sampling | 12 kHz |
Channel Sampling Rate | .125 seconds |
Integration Period | 1, 3, 15, 30 seconds; 1, 2, 5, 10, 15, 20, and 30 minutes; 1 and 12 hours, 1 day |
Energy Measurements | Volts, Amps, Amp-Hrs (Ah), kW, kWh, kVAR, kVARh, kVA, kVAh, Displacement Power Factor (dPF). All parameters for each phase and for system total. |
Analog Measurements | 0-10 Volts, 0-20 or 4-20 mA current loop. Non-isolated, external power for current loop. User scaling for sensor reporting in physical units. |
Accuracy | Better than 1% (<0.2% typical) for V, A, kW, kVAR, kVA, PF, Analog |
Resolution | 0.01 Amp, 0.001 Volt, 1 Watt, 1 VAR, 1 VA, 0.01 PF, 0.001 ANA |
LED Indicators | Tri-color (red, green, blue): 1 LED indicates communication (blue for wireless, Bluetooth® or Ethernet), 4 LEDs for correct phasing (PhaseChek™). |
POWER | |
Line-Power | From L1 Phase to L2 Phase. 80-600V (AC or DC) CAT III DC/50/60 Hz, 125 mA, 5 W, or 10 VA max. Non-user replaceable .5 Amp internal fuse protection. |
Power In | 6-10 VDC, 500 mA |
Power Out | 6 VDC, 200 mA max |
COMMUNICATIONS | |
USB (Standard) | USB standard (Type B). 1.8 M (6 ft) A-to-B USB Cable (included) |
Ethernet (Standard) | Standard RJ-45 Connector supports 10/100 MB Ethernet over Cat 5 or better. Configure for DHCP or Static IP. |
MECHANICAL | |
Operating Temperature | -7 to + 60 °C (20 to 140 °F) |
Operating Humidity | 5% to 95% non-condensing |
Enclosure Type | ABS plastic, 94-V0 flammability rating |
Weight | 340 g (12 ounces) |
Dimensions | 21.6 x 6.3 x 4.7 cm (8.5” x 2.5” x 1.9”) |
- • Verification Studies
- • True RMS Current Reading
- • Load Profiling
- • Energy Audits
- • Energy Surveys
Products In This Series
As low as
Now $1,980.00As low as
Now $1,865.00