DENT Instruments EXCUN ELITEpro XC Energy Logger (Ethernet & USB Communication)

SKU
EXCUN
Manufacturer:
DENT Instruments
DENT Instruments

Key Features:

  • Ethernet & USB communications
  • Measures energy metrics on up to 4 channels with current from 0-6000 amps
  • Use on single or three-phase systems
  • Analog inputs record analog data with configurable input ranges for voltage (0-10VDC) or current loop (0 or 4-20mA) transducers
  • Line powered
  • Integration periods are user selectable
  • Months of recording time with standard 16 MB nonvolatile memory
  • Better than 1% accuracy (<0.5% typical)
  • PhaseChek™ LED indicators ensure proper CT placement
  • Supplied with Windows-based ELOG Software for setup, analysis, data retrieval and more
Product Options:
$1,650.00

Secured and trusted checkout with

DENT Instrument’s ELITEpro XC series of wireless energy data loggers now features the EXCUN Energy Logger with Ethernet and USB Communications. The EXCUN measures, stores and analyzes electrical consumption data; a derivative from the current and voltage inputs. Using direct connections to each phase of the voltage and assorted interchangeable CT options, like split-core current transformers or RoCoils, the EXCUN monitors current on each phase. See the accessories tab for available DENT CTs. Now, the EXCUN ELITEpro XC comes equipped with 4 analog input channels which users can configure for either voltage or current input.


The energy logger has the capacity to capture kWh/kW energy and demand data in addition to nearly all pertinent energy parameters for diagnostics and monitoring on three-phase or single-phase circuit installations.


The EXCUN is explicitly configured with an Ethernet port and standard USB. In addition to connecting directly to the energy logger, the ELITEpro XC is capable of remote data downloads via a local area network.


* Supports 10/100 MB Ethernet over Cat 5 or better and can be configured for DHCP or static IP

TECHNICAL

Service Type

Single Phase (two wire or three wire), Three Phase-Four Wire (WYE), Three Phase-Three Wire (Delta), DC Systems (Solar/Battery)

Voltage Channels

3 channels, CAT III, 0-600 VAC (line-to-line) or 600 VDC*

Current Channels

4 channels, .67 VAC max, +/- 1 VDC. Ideal for 333 mV full scale CTs

Maximum Current Input

External transducer dependent.

200% of current transducer rating (mV CTs)

Measure up to 6000A with RoCoil CTs.

Measurement Type

True RMS using high-speed digital signal processing (DSP)

Line Frequency

DC/50/60 Hz*

Waveform Sampling

12 kHz

Channel Sampling Rate

.125 seconds

Integration Period

1, 3, 15, 30 seconds; 1, 2, 5, 10, 15, 20, and 30 minutes; 1 and 12 hours, 1 day

Energy Measurements

Volts, Amps, Amp-Hrs (Ah), kW, kWh, kVAR, kVARh, kVA, kVAh, Displacement Power Factor (dPF). All parameters for each phase and for system total.

Analog Measurements

0-10 Volts, 0-20 or 4-20 mA current loop. Non-isolated, external power for current loop. User scaling for sensor reporting in physical units.

Accuracy

Better than 1% (<0.2% typical) for V, A, kW, kVAR, kVA, PF, Analog

Resolution

0.01 Amp, 0.001 Volt, 1 Watt, 1 VAR, 1 VA, 0.01 PF, 0.001 ANA

LED Indicators

Tri-color (red, green, blue): 1 LED indicates communication (blue for wireless, Bluetooth® or Ethernet), 4 LEDs for correct phasing (PhaseChek™).

POWER

Line-Power

From L1 Phase to L2 Phase. 80-600V (AC or DC) CAT III DC/50/60 Hz, 125 mA, 5 W, or 10 VA max. Non-user replaceable .5 Amp internal fuse protection.

Power In

6-10 VDC, 500 mA

Power Out

6 VDC, 200 mA max

COMMUNICATIONS

USB (Standard)

USB standard (Type B). 1.8 M (6 ft) A-to-B USB Cable (included)

Ethernet (Standard)

Standard RJ-45 Connector supports 10/100 MB Ethernet over Cat 5 or better. Configure for DHCP or Static IP.

MECHANICAL

Operating Temperature

-7 to + 60 °C (20 to 140 °F)

Operating Humidity

5% to 95% non-condensing

Enclosure Type

ABS plastic, 94-V0 flammability rating

Weight

340 g (12 ounces)

Dimensions

21.6 x 6.3 x 4.7 cm (8.5” x 2.5” x 1.9”)