Model |
| PSU | 6-200 | 12.5-120 | 20-76 | 40-38 | 60-25 | 100-15 | 150-10 | 300-5 | 400-3.8 | 600-2.6 |
Output ratings | ||||||||||||
Rated output voltage (*1) |   | V | 6 | 12.5 | 20 | 40 | 60 | 100 | 150 | 300 | 400 | 600 |
Rated output current (*2) |   | A | 200 | 120 | 76 | 38 | 25 | 15 | 10 | 5 | 3.8 | 2.6 |
Rated output power |   | W | 1200 | 1500 | 1520 | 1520 | 1500 | 1500 | 1500 | 1500 | 1520 | 1560 |
Ripple and noise(*5) | ||||||||||||
CVp-p( 10 ~ 20MHz) | p-p (*6) | mV | 60 | 60 | 60 | 60 | 60 | 80 | 100 | 150 | 200 | 300 |
CVrms(5Hz ~ 1MHz) | r.m.s. (*7) | mV | 8 | 8 | 8 | 8 | 8 | 8 | 10 | 25 | 40 | 60 |
CCrms(5Hz ~ 1MHz) | r.m.s.(*12) | mA | 400 | 240 | 152 | 95 | 75 | 45 | 35 | 25 | 17 | 12 |
Load regulation | ||||||||||||
Voltage(*4) |   | mV | 2.6 | 3.25 | 4 | 6 | 8 | 12 | 17 | 32 | 42 | 62 |
Current(*11) |   | mA | 45 | 29 | 20.2 | 12.6 | 10 | 8 | 7 | 6 | 5.76 | 5.52 |
Line regulation  | ||||||||||||
Voltage(*3) |   | mV | 2.6 | 3.25 | 4 | 6 | 8 | 12 | 17 | 32 | 42 | 62 |
Current(*3) |   | mA | 22 | 14 | 9.6 | 5.8 | 4.5 | 3.5 | 3 | 2.5 | 2.38 | 2.26 |
Analog Programming and Monitoring  | ||||||||||||
External voltage control output voltage |   |   | Accuracy and linearity: ±0.5% of rated output voltage. | |||||||||
External voltage control output current |   |   | Accuracy and linearity: ±1% of rated output current. | |||||||||
External resistor control output voltage |   |   | Accuracy and linearity: ±1% of rated output voltage. | |||||||||
External resistor control output current |   |   | Accuracy and linearity: ±1.5% of rated output current. | |||||||||
Output voltage monitor |   |   | Accuracy: ±1% | |||||||||
Output current monitor |   |   | Accuracy: ±1% | |||||||||
Shutdown control |   |   | Turns the output off with a LOW (0V to 0.5V) or short-circuit. | |||||||||
Output on/off control |   |   | Possible logic selections: | |||||||||
Turn the output on using a LOW (0V to 0.5V) or short-circuit, turn the output off using a HIGH (4.5V to 5V) or open-circuit. | ||||||||||||
Turn the output on using a HIGH (4.5V to 5V) or open-circuit, turn the output off using a LOW | ||||||||||||
Alarm clear control |   |   | Clear alarms with a LOW (0V to 0.5V) or short-circuit. | |||||||||
CV/CC/ALM/PWR ON/OUT ON indicator |   |   | Photocoupler open collector output; Maximum voltage 30V, maximum sink current 8mA. | |||||||||
Trigger out |   |   | Maximum low level output = 0.8V; minimum high level output = 2V; Maximum source current = 8mA. | |||||||||
Trigger in |   |   | Maximum low level input voltage = 0.8V; minimum high level input votage = 2V, Maximum sink current = 8mA. | |||||||||
Front Panel | ||||||||||||
Display, 4 digits, Voltage accuracy | 0.1% + | mV | 12 | 25 | 40 | 80 | 120 | 200 | 300 | 600 | 800 | 1200 |
Current accuracy | 0.2% + | mA | 600 | 360 | 228 | 114 | 75 | 45 | 30 | 15 | 11.4 | 7.8 |
Indications |   |   | GREEN LED's: CV, CC, V, A, VSR, ISR, DLY, RMT, LAN, M1, M2, M3, RUN,OutputON | |||||||||
  |   |   | RED LED's: ALM, ERR | |||||||||
Buttons |   |   | Lock/Local(Unlock), PROT(ALM_CLR), Function(M1), Test(M2), Set(M3), Shift, Output | |||||||||
Knobs |   |   | Voltage, Current | |||||||||
USB port |   |   | Type A USB connector | |||||||||
Transient response time (*10) | ||||||||||||
Transient response time |   | ms | 1.5 | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 |
Output response time | ||||||||||||
Rise time (*8) | Rated load | ms | 80 | 80 | 80 | 80 | 80 | 150 | 150 | 150 | 200 | 250 |
  | No load | ms | 80 | 80 | 80 | 80 | 80 | 150 | 150 | 150 | 200 | 250 |
Fall time(*9) | Rated load | ms | 10 | 50 | 50 | 80 | 80 | 150 | 150 | 150 | 200 | 250 |
  | No load | ms | 500 | 700 | 800 | 1000 | 1100 | 1500 | 2000 | 2500 | 3000 | 4000 |
Programming and Measurements (RS-232/485, USB, LAN, GPIB) | ||||||||||||
Output voltage programming accuracy | 0.05% + | mV | 3 | 6.25 | 10 | 20 | 30 | 50 | 75 | 150 | 200 | 300 |
Output current programming accuracy | 0.2% + | mA | 200 | 120 | 76 | 38 | 25 | 15 | 10 | 5 | 3.8 | 2.6 |
Output voltage programming resolution |   | mV | 0.2 | 0.4 | 0.7 | 1.3 | 2 | 3.4 | 5.2 | 10.2 | 13.6 | 20.4 |
Output current programming resolution |   | mA | 6 | 4 | 2.5 | 1.2 | 0.8 | 0.5 | 0.34 | 0.19 | 0.13 | 0.09 |
Output voltage measurement accuracy | 0.1% + | mV | 6 | 12.5 | 20 | 40 | 60 | 100 | 150 | 300 | 400 | 600 |
Output current measurement accuracy | 0.2% + | mA | 400 | 240 | 152 | 76 | 50 | 30 | 20 | 10 | 7.6 | 5.2 |
Output voltage measurement resolution |   | mV | 0.2 | 0.4 | 0.7 | 1.3 | 2 | 3.4 | 5.2 | 10.2 | 13.6 | 20.4 |
Output current measurement resolution |   | mA | 6 | 4 | 2.5 | 1.2 | 0.8 | 0.5 | 0.34 | 0.19 | 0.13 | 0.09 |
Temperature coefficience | ||||||||||||
Voltage |   | ppm/℃ | 100ppm/℃ after a 30 minute warm-up | |||||||||
Current |   | ppm/℃ | 100ppm/℃ after a 30 minute warm-up | |||||||||
Remote sense compensation voltage(single wire) | ||||||||||||
voltage |   | V | 1 | 1 | 1 | 2 | 3 | 5 | 5 | 5 | 5 | 5 |
Protection Function  | ||||||||||||
Over voltage protection(OVP) | Setting range | V | 0.6 - 6.6 | 1.25 - 13.75 | 2 - 22 | 4 - 44 | 5 - 66 | 5 - 110 | 5 - 165 | 5 - 330 | 5 - 440 | 5 - 660 |
  | Setting accuracy | mV | 60 | 125 | 200 | 400 | 600 | 1000 | 1500 | 3000 | 4000 | 6000 |
Over current protection(OCP) | Setting range | A | 5 - 220 | 5 - 132 | 5 - 83.6 | 3.8 - 41.8 | 2.5 - 27.5 | 1.5 - 16.5 | 1 - 11 | 0.5 - 5.5 | 0.38 - 4.18 | 0.26 - 2.86 |
  | Setting accuracy | mA | 4000 | 2400 | 1520 | 760 | 500 | 300 | 200 | 100 | 76 | 52 |
Under voltage limit(UVL) | Setting range |   | 0 - 6.3 | 0 - 13.12 | 0 - 21 | 0 - 42 | 0 - 63 | 0 - 105 | 0 - 157.5 | 0 - 315 | 0 - 420 | 0 - 630 |
Over temperature protection(OHP) | Operation |   | Turn the output off. | |||||||||
Incorrect sensing connection protection (SENSE) | Operation |   | Turn the output off. | |||||||||
Low AC input protection (AC-FAIL) | Operation |   | Turn the output off. | |||||||||
Shutdown (SD) | Operation |   | Turn the output off. | |||||||||
Power limit (POWER LIMIT) | Operation |   | Over power limit. | |||||||||
  | Value (fixed) |   | Approx. 105% of rated output power | |||||||||
Interface Capabilities | ||||||||||||
USB |   |   | TypeA: Host, TypeB: Slave, Speed: 1.1/2.0, USB Class: CDC(Communications Device Class) | |||||||||
LAN |   |   | MAC Address, DNS IP Address, User Password, Gateway IP Address, Instrument IP Address, Subnet Mask | |||||||||
RS-232 / RS-485 |   |   | Complies with the EIA232D / EIA485 Specifications | |||||||||
GPIB (Factory Option) |   |   | SCPI - 1993, IEEE 488.2 compliant interface | |||||||||
Isolated Analog Control Interface (Factory Option)  | ||||||||||||
Voltage Control |   |   | Using 0-5V or 0-10V signals for programming and measurement | |||||||||
Current Control |   |   | Using 4-20mA current signals for programming and measurement | |||||||||
Environmental Conditions | ||||||||||||
Operating temperature |   |   | 0˚C to 50˚C | |||||||||
Storage temperature |   |   | -25˚C to 70˚C | |||||||||
Operating humidity |   |   | 20% to 85% RH; No condensation | |||||||||
Storage humidity |   |   | 90% RH or less; No condensation | |||||||||
Altitude |   |   | Maximum2000m | |||||||||
Input Characteristics | ||||||||||||
Nominal input rating |   |   | 100Vac to 240Vac, 50Hz to 60Hz, single phase | |||||||||
Input voltage range |   |   | 85Vac ~ 265Vac | |||||||||
Input frequency range |   |   | 47Hz ~ 63Hz | |||||||||
Maximum input current | 100Vac / 200Vac | A | 21 / 11 | |||||||||
Inrush current |   |   | Less than50A. | |||||||||
Maximum input power |   | VA | 2000 | |||||||||
Power factor | 100Vac / 200Vac |   | 0.99 / 0.98 | |||||||||
Efficiency (*13) | 100Vac / 200Vac | % | 77 / 79 | 82 / 85 | 83 / 86 | 84 / 87 | 84 / 87 | 84 / 87 | 84 / 87 | 84 / 87 | 84 / 87 | 84 / 87 |
Hold-up time |   |   | 20ms or greater | |||||||||
General | ||||||||||||
Weight | main unit only | kg | Less than8.7kg | |||||||||
Dimensions | (W×H×D) | mm^3 | 423×43.6×447.2 | |||||||||
Cooling |   |   | Forced air cooling by internal fan. | |||||||||
EMC |   |   | Complies with the European EMC directive 89/336/EEC for Class A test and measurement products. | |||||||||
Safety |   |   | Complies with the European Low Voltage Directive 73/23/EEC and carries the CE-marking. | |||||||||
Withstand voltage |   |   | AC to Chassis : 1500Vac / 1min | |||||||||
AC to Output terminal : 3000Vac / 1min | ||||||||||||
Vout≦150V | ||||||||||||
Output terminal to Chassis : 1000Vdc / 1min | ||||||||||||
150<Vout≦600 | ||||||||||||
Output terminal to Chassis : 1500Vdc / 1min | ||||||||||||
Insulation resistances |   |   | Chassis and output terminal; chassis and AC input; AC input and output terminal: 100MΩ or more (DC 1000V) |