The PSU 60-25 has a power range up to 1500W. The PSU 60-25 can be joined series for maximum 2 units or in parallel for maximum 4 units. A very useful feature for DUT protection are the CV and CC selections. CV mode works when the power supply is turned on and when the CC mode is activated the current becomes stable. To limit the current spike occurred at the threshold voltage and protect the DUT from the inrush current damage the PSU-Series is able to run under CC priority.
Another way the PSU prevents DUT damage is with the OVP and OCP protections. Both the OVP and OCP levels can select the range of 10% to 110%, with the default level set at 110%, of the rated voltage / current of the power supply. The PSU has available at the rear panel the LabView driver. The driver is for external control of the power On/Off and the external monitoring of the power output voltage and current.
Output | |||||||
Model |
| PSU | 6-200 | 12.5-120 | 20-76 | 40-38 | 60-25 |
Rated Output Voltage (*1) |
| V | 6 | 12.5 | 20 | 40 | 60 |
Rated Output Current (*2) |
| A | 200 | 120 | 76 | 38 | 25 |
Rated Output Power |
| W | 1200 | 1500 | 1520 | 1520 | 1500 |
Constant Voltage Mode | |||||||
Model |
| PSU | 6-200 | 12.5-120 | 20-76 | 40-38 | 60-25 |
Line regulation (*3) |
| mV | 2.6 | 3.25 | 4 | 6 | 8 |
Load regulation (*4) |
| mV | 2.6 | 3.25 | 4 | 6 | 8 |
Ripple and noise (*5) | p-p (*6) | mV | 60 | 60 | 60 | 60 | 60 |
| r.m.s. (*7) | mV | 8 | 8 | 8 | 8 | 8 |
Temperature coefficient |
| ppm/ °C | 100ppm/°C of rated output voltage, after a 30 minute warm-up. | ||||
Remote sense compensation voltage (single wire) |
| V | 1 | 1 | 1 | 2 | 3 |
Rise time (*8) | Rated load | ms | 80 | 80 | 80 | 80 | 80 |
| No load | ms | 80 | 80 | 80 | 80 | 80 |
Fall time (*9) | Rated load | ms | 10 | 50 | 50 | 80 | 80 |
| No load | ms | 500 | 700 | 800 | 1000 | 1100 |
Transient response time (*10) |
| ms | 1.5 | 1 | 1 | 1 | 1 |
Constant Current Mode | |||||||
Model |
| PSU | 6-200 | 12.5-120 | 20-76 | 40-38 | 60-25 |
Line regulation (*3) |
| mA | 22 | 14 | 9.6 | 5.8 | 4.5 |
Load regulation (*11) |
| mA | 45 | 29 | 20.2 | 12.6 | 10 |
Ripple and noise (*12) | r.m.s. | mA | 400 | 240 | 152 | 95 | 75 |
Temperature coefficient |
| ppm/ °C | 100ppm/°C of rated output voltage, after a 30 minute warm-up. | ||||
Protection Function | |||||||
Model |
| PSU | 6-200 | 12.5-120 | 20-76 | 40-38 | 60-25 |
Over voltage protection (OVP) | Setting range | V | 0.6-6.6 | 1.25-13.75 | 2-22 | 4-44 | 5-66 |
| Setting accuracy | V | 0.06 | 0.125 | 0.2 | 0.4 | 0.6 |
Over current protection (OCP) | Setting range | A | 5-220 | 5-132 | 5-83.6 | 3.8-41.8 | 2.5-27.5 |
| Setting accuracy | A | 4 | 2.4 | 1.52 | 0.76 | 0.5 |
Under voltage limit (UVL) | Setting range |
| 0-6.3 | 0-13.12 | 0-21 | 0-42 | 0-63 |
Over temperature protection (OHP) | Operation |
| Turn the output off. | ||||
Incorrect sensing connection protection (SENSE) | Operation |
| Turn the output off. | ||||
Low AC input protection (AC-FAIL) | Operation |
| Turn the output off. | ||||
Shutdown (SD) | Operation |
| Turn the output off. | ||||
Power limit (POWER LIMIT) | Operation |
| Over power limit. | ||||
| Value (fixed) |
| Approx. 105% of rated output power | ||||
Analog Programming and Monitoring | |||||||
Model |
| PSU | 6-200 | 12.5-120 | 20-76 | 40-38 | 60-25 |
External voltage control output voltage |
|
| Turn the output off. | ||||
External voltage control output current |
|
| Turn the output off. | ||||
External resistor control output voltage |
|
| Turn the output off. | ||||
External resistor control output current |
|
| Turn the output off. | ||||
Output voltage monitor |
|
| Turn the output off. | ||||
Output current monitor |
|
| Turn the output off. | ||||
Shutdown control |
|
| Turns the output off with a LOW (0V to 0.5V) or short-circuit. | ||||
Output on/off control |
|
| Possible logic selections: | ||||
Alarm clear control |
|
| Clear alarms with a LOW (0V to 0.5V) or short-circuit. | ||||
CV/CC/ALM/PWR ON/OUT ON indicator |
|
| Photocoupler open collector output; Maximum voltage 30V, maximum sink current 8mA. | ||||
Trigger out |
|
| Maximum low level output = 0.8V; minimum high level output = 2V; Maximum source current = 8mA. | ||||
Trigger in |
|
| Maximum low level input voltage = 0.8V; minimum high level input votage = 2.0V, Maximum sink current = 8mA. | ||||
Front Panel | |||||||
Model |
| PSU | 6-200 | 12.5-120 | 20-76 | 40-38 | 60-25 |
Display, 4 digits |
|
|
|
|
|
|
|
Voltage accuracy | 0.1% + | mV | 12 | 25 | 40 | 80 | 120 |
Current accuracy | 0.2% + | mA | 600 | 360 | 228 | 114 | 75 |
Indications |
|
| GREEN LED's: CV, CC, V, A, VSR, ISR, DLY, RMT, LAN, M1, M2, M3, RUN, Output ON | ||||
Buttons |
|
| Lock/Local(Unlock), PROT(ALM_CLR), Function(M1), Test(M2), Set(M3), Shift, Output | ||||
Knobs |
|
| Voltage, Current | ||||
USB port |
|
| Type A USB connector | ||||
Programming and Measurement (RS-232/485, USB, LAN, GPIB) | |||||||
Model |
| PSU | 6-200 | 12.5-120 | 20-76 | 40-38 | 60-25 |
Output voltage programming accuracy | 0.05% + | mV | 3 | 6.25 | 10 | 20 | 30 |
Output current programming accuracy | 0.2% + | mA | 200 | 120 | 76 | 38 | 25 |
Output voltage programming resolution |
| mV | 0.2 | 0.4 | 0.7 | 1.3 | 2 |
Output current programming resolution |
| mA | 6 | 4 | 2.5 | 1.2 | 0.8 |
Output voltage measurement accuracy | 0.1% + | mV | 6 | 12.5 | 20 | 40 | 60 |
Output current measurement accuracy | 0.2% + | mA | 400 | 240 | 152 | 76 | 50 |
Output voltage measurement resolution |
| mV | 0.2 | 0.4 | 0.7 | 1.3 | 2 |
Output current measurement resolution |
| mA | 6 | 4 | 2.5 | 1.2 | 0.8 |
Input Characteristics | |||||||
Model |
| PSU | 6-200 | 12.5-120 | 20-76 | 40-38 | 60-25 |
Norminal input rating |
|
| 100Vac to 240Vac, 50Hz to 60Hz, single phase | ||||
Input voltage range |
|
| 85Vac ~ 265Vac | ||||
Input frequency range |
|
| 47Hz ~ 63Hz | ||||
Maximum input current | 100Vac | A | 21 | ||||
| 200Vac | A | 11 | ||||
Inrush current |
|
| Less than 50A. | ||||
Maximum input power |
| VA | 2000 | ||||
Power factor | 100Vac |
| 0.99 | ||||
| 200Vac |
| 0.98 | ||||
Efficiency (*13) | 100Vac |
| 77 | 82 | 83 | 84 | 84 |
| 200Vac |
| 79 | 85 | 86 | 87 | 87 |
Hold-up time |
|
| 20ms or greater | ||||
Interface Capabilities | |||||||
Model |
| PSU | 6-200 | 12.5-120 | 20-76 | 40-38 | 60-25 |
USB |
|
| TypeA: Host, TypeB: Slave, Speed: 1.1/2.0, USB Class: CDC(Communications Device Class) | ||||
LAN |
|
| MAC Address, DNS IP Address, User Password, Gateway IP Address, Instrument IP Address, Subnet Mask | ||||
GPIB |
|
| SCPI - 1993, IEEE 488.2 compliant interface | ||||
RS-232/RS-485 |
|
| Complies with EIA232D / EIA485 Specifications | ||||
Environment Conditions | |||||||
Model |
| PSU | 6-200 | 12.5-120 | 20-76 | 40-38 | 60-25 |
Operaing temperature |
|
| 0˚C to 50˚C | ||||
Storage temperature |
|
| -25˚C to 70˚C | ||||
Operating humidity |
|
| 20% to 85% RH; No condensation | ||||
Storage humidity |
|
| 90% RH or less; No condensation | ||||
Altitude |
|
| Maximum 2000m | ||||
Environment Conditions | |||||||
Model |
| PSU | 6-200 | 12.5-120 | 20-76 | 40-38 | 60-25 |
Weight | main unit only | kg | Less than 8.7kg | ||||
Dimensions | (W×H×D) | mm3 | 423×43.6×447.2 | ||||
Cooling |
|
| Forced air cooling by internal fan. | ||||
EMC |
|
| Complies with the European EMC directive 2004 /108/EC for Class A test and measurement products. | ||||
Safety |
|
| Complies with the European Low Voltage Directive 2006 /95/EC and carries the CE-marking. | ||||
Withstand voltage |
|
| AC to Chassis: 1500Vac/1min | ||||
Insulation resistance |
|
| Chassis and output terminal; chassis and AC input; AC input and output terminal: 100MΩ or more (DC 500V) | ||||
|
|
|
|
|
|
|
|
Notes: |