BK Precision MDL4U400 80V/60A/400W Single-channel DC Electronic Load Module

SKU
MDL4U400
Manufacturer:
B&K Precision
B&K Precision

Key Features:

  • Module offer wide voltage and current range, 0 to 80 V, 0 to 60 A
  • Single-Channel
  • Transient mode up to 25 kHz
  • Synchronous Load on/off function
  • Adjustable slew rate in CC mode
  • Short circuit test simulates a short at the input
  • Built-in 16-bit resolution voltage and current measurement (0.1 mV, 0.01 mA)
  • Remote voltage sensing to compensate for the effect of voltage drop in wires
  • Operate identical modules in parallel mode for high current applications
  • OVP/OCP/OPP/OTP and reverse voltage protection
$1,965.00

Secured and trusted checkout with

The BK Precision MDL4U400 is a single-channel DC load module that works with the MDL4U001 Mainframe and MDL4U002 Mainframe Extension. The MDL4U400 input voltage is 80 V, input current is 60 A, and input power is 400 W.

Model

MDL4U200

MDL4U252

MDL4U302

MDL4U305

MDL4U400

MDL4U505

MDL4U600

Input rating

Input Voltage

0 to 80 V

0 to 80 V

0 to 80 V

0 to 500 V

0 to 80 V

0 to 500 V

0 to 80 V

Input

Current

Low

0 to 4 A

0 to 3 A

0 to 4.5 A

0 to 3 A

0 to 6 A

0 to 3 A

0 to 12 A

High

0 to 40 A

0 to 20 A

0 to 45 A

0 to 20 A

0 to 60 A

0 to 30 A

0 to 120 A

Input Power

200 W

250 W / 50 W (1)

300 W / 300 W (1)

300 W

400 W

500 W

600 W

Channels

1

2

2

1

1

1

1

Minimum Operating Voltage

Low

0.10 V at 4 A

0.15 V at 3 A

0.14 V at 4.5 A

0.7 V at 3 A

0.15 V at 6 A

0.54 V at 3 A

0.18 V at 12 A

High

1 V at 40 A

1 V at 20 A

1.4 V at 45 A

4.5 V at 20 A

1.5 V at 60 A

5.4 V at 30 A

1.8 V at 120 A

CV mode

 

Range

Low

0 to 18 V

High

0 to 80 V

0 to 500 V

0 to 80 V

0 to 500 V

0 to 80 V

 

Resolution

Low

1 mV

High

10 mV

 

Accuracy

Low

± (0.05% + 0.02% F.S.)

± (0.05  % + 0.025% F.S.)

± (0.05% + 0.02% F.S.)

High

± (0.05% + 0.025% F.S.)

CC mode

 

Range

Low

0 to 4 A

0 to 3 A

0 to 4.5 A

0 to 3 A

0 to 6 A

0 to 3 A

0 to 12 A

High

0 to 40 A

0 to 20 A

0 to 45 A

0 to 20 A

0 to 60 A

0 to 30 A

0 to 120 A

 

Resolution

Low

0.1 mA

1 mA

0.1 mA

High

1 mA

10 mA

1 mA

 

Accuracy

Low

± (0.05% + 0.05% F.S.)

± (0.05% + 0.1% F.S.)

High

± (0.05% + 0.05% F.S.)

± (0.1% + 0.1% F.S.)

CR mode

 

Range

Low

0.05 Ω to 10 Ω

0.25 Ω to 10 Ω

0.05 Ω to 10 Ω

0.2 Ω to 10 Ω

High

10 Ω to 7.5 kΩ

Resolution

16-bit

 

Accuracy

Low

0.01% + 0.08 S

High

0.01% + 0.0008 S

CW mode

Range

200 W

250 W

300 W

400 W

500 W

600 W

Resolution

10 mW

Accuracy

± (0.2% + 0.2% F.S.)

Transient mode (CC mode)

T1&T2(2)

20 μs to 3600 s / Res: 5 μs to 10 ms

Accuracy

5 μs + 100 ppm

 

Slew Rate(3)

Low

0.0001 to 0.25 A/μs

0.0001 to 0.2 A/μs

0.0001 to 0.25 A/μs

0.0001 to 0.1 A/μs

0.0001 to 0.25 A/μs

0.0001 to 0.1 A/μs

0.0001 to 0.25 A /μs

High

0.001 to 2.5 A/μs

0.001 to 2 A/μs

0.001 to 2.5 A/μs

0.001 to 1 A/μs

0.001 to 2.5 A/μs

0.001 to 1 A/μs

0.001 to 2.5 A/μs

(1) MDL4U252: The user can allocate 250 W to either channel up to 300 W total (e.g. 50 W/250 W, 250 W/50 W, 150 W/150 W). MDL4U302: The user can allocate 300 W to either channel up to 600 W total (e.g. 300 W/300 W).
(2) Fast pulse trains with large transitions may not be achievable.
(3) The slew rate specifications are not warranted, but are descriptions of typical performance. The actual transition time is defined as the time for the input to change from 10% to 90%, or vice versa, of the programmed current values. In case of very large load changes, e.g. from no load to full load, the actual transition time will be larger than the expected time. The load will automatically adjust the slew rate to fit within the range (high or low) that is closest to the programmed value.

 

Model

MDL4U200

MDL4U252

MDL4U302

MDL4U305

MDL4U400

MDL4U505

MDL4U600

Readback voltage

 

Range

Low

0 to 18 V

High

0 to 80 V

0 to 500 V

0 to 80 V

0 to 500 V

0 to 80 V

 

Resolution

Low

0.1 mV

1 mV

0.1 mV

1 mV

0.1 mV

High

1 mV

10 mV

1 mV

10 mV

1 mV

Accuracy

± (0.025% + 0.025% F.S.)

Readback current

 

Range

Low

0 to 4 A

0 to 3 A

0 to 4.5 A

0 to 3 A

0 to 6 A

0 to 3 A

0 to 12 A

High

0 to 40 A

0 to 20 A

0 to 45 A

0 to 20 A

0 to 60 A

0 to 30 A

0 to 120 A

 

Resolution

Low

0.01 mA

0.1 mA

0.01 mA

0.1 mA

High

0.1 mA

1 mA

0.1 mA

1 mA

 

Accuracy

Low

± (0.05% + 0.05% F.S.)

± (0.05% + 0.1% F.S.)

High

± (0.05% + 0.05% F.S.)

± (0.1% + 0.1% F.S.)

Readback power

Range

200 W

250 W

300 W

400 W

500 W

600 W

Resolution

10 mW

Accuracy

± (0.2% + 0.2% F.S.)

Protection range (typical)

OPP

200 W

250 W

310 W

300 W

400 W

500 W

600 W

 

OCP

Low

4.4 A

3.3 A

5 A

3.3 A

6.6 A

3.3 A

13.2 A

High

44 A

22 A

50 A

22 A

66 A

33 A

132 A

OVP

82 V

510 V

82 V

510 V

82 V

OTP

185 ºF (85 ºC)

General (typical)

Short Circuit

 

Current (CC)

Low

4 A

3 A

5 A

3 A

6 A

3 A

12 A

High

40 A

30 A

50 A

20 A

60 A

30 A

120 A

Voltage (CV)

0 V

Resistance (CR)

25 mΩ

50 mΩ

30 mΩ

220 mΩ

25 mΩ

180 mΩ

15 mΩ

Input Terminal Impedance

300 kΩ

1 MΩ

300 kΩ

1 MΩ

300 kΩ

Safety

EN61010-1:2010, EU Low Voltage Directive  (LVD) 2014/35/EU

Electromagnetic

Compatibility


Meets EMC Directive 2014/30/EU, EN61326-1:2013

Warranty

3 Years

Dimensions

3.2” x 6.7” x 22.6” (82 x 170.5 x 573 mm)

Weight

11 lbs (5 kg)

 

Write Your Own Review