We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
Providing high level of functionality and monitoring capability, the Gas Monitor S200 can be used portably or fixed in position. The monitor is compatible with the wide range of toxic gas sensors. The remote sensor head adaptor kit is designed to allow the sensor head to be located up to 46 ft away from the main unit.
*Order Gas Sensor Head's Separately
Measurments Units |
ppm or mg/m3 |
Sensor Head |
Removable and Replaceable |
Functions |
Low battery indication |
Power Supply |
Li-Ion Battery (lasts up to 8 hrs) or AC Adapter |
Enclosure Rating |
IP20 & NEMA 1 equivalent |
Dimensions (with sensor head) |
7.0 x 4.75 x 2.0 inches (195 x 122 x 54 mm) |
Weight (with sensor & battery) |
< 16 oz (460 g) |
Approvals |
Part 15 of FCC Rules |
Gas Sensor Head Specifications *Order Gas Sensor Head Separately
Sensor |
Range (ppm) |
Accuracy of |
Min. Detection Limit (ppm) |
Resolution |
Operational Range |
|
Temperature |
RH |
|||||
Ammonia |
0-100 |
<±10% |
0.2 |
0.1 |
32-104°F |
10-90% |
Ammonia (leak) |
0-1000 |
<±15% |
2 |
1 |
32-104°F |
10-90% |
Carbon Monoxide |
0-25 |
<±0.5 ppm 0-5 ppm; |
0.05 |
0.01 |
32-104°F |
10-90% |
Carbon Monoxide |
0-100 |
<±1 ppm 0-10 ppm; |
0.2 |
0.1 |
32-104°F |
10-90% |
Carbon Monoxide |
0-1000 |
<±10% |
1 |
1 |
32-104°F |
10-90% |
Carbon Dioxide |
0-2000 |
<±10 ppm +5% |
10 |
1 |
32-104°F |
10-90% |
Carbon Dioxide |
0-5000 |
<±20 ppm +5% |
20 |
1 |
32-104°F |
10-90% |
Chlorine |
0-10 |
<±10% |
0.02 |
0.01 |
32-104°F |
10-90% |
Formaldehyde |
0-10 |
<±0.05 ppm 0-0.5 ppm; |
0.01 |
0.01 |
32-104°F |
10-90% |
Hydrogen |
0-5000 |
<±10% |
5 |
1 |
32-104°F |
10-90% |
Hydrogen Sulphide |
0-10 |
<±0.05 ppm 0-0.5 ppm; |
0.04 |
0.01 |
32-104°F |
10-90% |
Hydrogen Sulphide |
0-100 |
<±0.5 ppm 0-5 ppm; |
0.4 |
0.1 |
32-104°F |
10-90% |
Methane |
0-10000 |
<±15% |
10 |
1 |
32-104°F |
10-90% |
Nitrogen Dioxide |
0-1 |
<±0.02 ppm 0-0.2 ppm; |
0.005 |
0.001 |
32-104°F |
10-90% |
Ozone |
0-0.15 |
<±0.005 ppm |
0.001 |
0.001 |
32-104°F |
10-90% |
Ozone |
0-0.5 |
<±0.008 ppm 0-0.1 ppm; |
0.001 |
0.001 |
32-104°F |
10-90% |
Ozone |
0-10 |
<±0.1 ppm 0-1 ppm; |
0.02 |
0.01 |
32-104°F |
10-90% |
Perchloroethylene |
0-200 |
<±5 ppm 0-50 ppm; |
1 |
1 |
32-104°F |
10-90% |
Sulphur Dioxide |
0-10 |
<±0.05 ppm 0-0.5 ppm; |
0.04 |
0.01 |
32-104°F |
10-90% |
Sulphur Dioxide |
0-100 |
<±0.5 ppm 0-5 ppm; |
0.4 |
0.1 |
32-104°F |
10-90% |
VOC (GSS sensor) |
0-25 |
<±10% |
0.1 |
0.1 |
32-104°F |
10-90% |
VOC (GSS sensor) |
0-500 |
<±10% |
1 |
1 |
32-104°F |
10-90% |
VOC (PID sensor) |
0-20 |
<±10% |
0.02 |
0.01 |
32-104°F |
10-90% |
VOC (PID sensor) |
0-1000 |
<±10% |
0.2 |
0.1 |
32-104°F |
10-90% |
Temperature |
-20-100°C |
<± 0.3°C |
|
0.01°C |
-40-248°F |
0-105% |
Humidity |
0 to 100% |
<± 2% RH |
|
1% RH |
-40-248°F |
0-105% |
Multi-Gas IAQ Sensor Heads
Sensor Head |
Gases |
Range |
Accuracy of |
Minimum |
Resolution |
Operational |
Operational |
MS1 |
CO |
0-2000 |
<±10 ppm +5% |
10 |
1 |
32-104°F |
10-90% |
MS2 |
CO |
0-2000 |
<±10 ppm +5% |
10 |
1 |
32-104°F |
10-90% |
- IAQ Investigation
- Industrial Hygiene Quality Control
- Occupational Safety and Health Testing
- US GBC LEED certification