Providing high level of functionality and monitoring capability, the Gas Monitor S200 can be used portably or fixed in position. The monitor is compatible with the wide range of toxic gas sensors. The remote sensor head adaptor kit is designed to allow the sensor head to be located up to 46 ft away from the main unit.
Part 15 of FCC Rules EN 50082-1: 1997 EN 50081-1: 1992
Gas Sensor Head Specifications*Order Gas Sensor Head Separately
Sensor
Range (ppm)
Accuracy of Calibration
Min. Detection Limit (ppm)
Resolution (ppm)
Operational Range
Temperature
RH
Ammonia
0-100
<±10%
0.2
0.1
32-104°F
10-90%
Ammonia (leak)
0-1000
<±15%
2
1
32-104°F
10-90%
Carbon Monoxide
0-25
<±0.5 ppm 0-5 ppm; <±10% 5-25 ppm
0.05
0.01
32-104°F
10-90%
Carbon Monoxide
0-100
<±1 ppm 0-10 ppm; <±10% 10-100 ppm
0.2
0.1
32-104°F
10-90%
Carbon Monoxide
0-1000
<±10%
1
1
32-104°F
10-90%
Carbon Dioxide
0-2000
<±10 ppm +5%
10
1
32-104°F
10-90%
Carbon Dioxide
0-5000
<±20 ppm +5%
20
1
32-104°F
10-90%
Chlorine
0-10
<±10%
0.02
0.01
32-104°F
10-90%
Formaldehyde
0-10
<±0.05 ppm 0-0.5 ppm; <±10% 0.5-10 ppm
0.01
0.01
32-104°F
10-90%
Hydrogen
0-5000
<±10%
5
1
32-104°F
10-90%
Hydrogen Sulphide
0-10
<±0.05 ppm 0-0.5 ppm; <±10% 0.5-10 ppm
0.04
0.01
32-104°F
10-90%
Hydrogen Sulphide
0-100
<±0.5 ppm 0-5 ppm; <±10% 5-100 ppm
0.4
0.1
32-104°F
10-90%
Methane
0-10000
<±15%
10
1
32-104°F
10-90%
Nitrogen Dioxide
0-1
<±0.02 ppm 0-0.2 ppm; <±10% 0.2-1 ppm
0.005
0.001
32-104°F
10-90%
Ozone
0-0.15
<±0.005 ppm
0.001
0.001
32-104°F
10-90%
Ozone
0-0.5
<±0.008 ppm 0-0.1 ppm; <±10% 0.1-0.5 ppm
0.001
0.001
32-104°F
10-90%
Ozone
0-10
<±0.1 ppm 0-1 ppm; 15% 1-10 ppm
0.02
0.01
32-104°F
10-90%
Perchloroethylene
0-200
<±5 ppm 0-50 ppm; <±10% 50-200 ppm
1
1
32-104°F
10-90%
Sulphur Dioxide
0-10
<±0.05 ppm 0-0.5 ppm; <±10% 0.5-10 ppm
0.04
0.01
32-104°F
10-90%
Sulphur Dioxide
0-100
<±0.5 ppm 0-5 ppm; <±10% 5-100 ppm
0.4
0.1
32-104°F
10-90%
VOC (GSS sensor)
0-25
<±10%
0.1
0.1
32-104°F
10-90%
VOC (GSS sensor)
0-500
<±10%
1
1
32-104°F
10-90%
VOC (PID sensor)
0-20
<±10%
0.02
0.01
32-104°F
10-90%
VOC (PID sensor)
0-1000
<±10%
0.2
0.1
32-104°F
10-90%
Temperature
-20-100°C
<± 0.3°C
0.01°C
-40-248°F
0-105%
Humidity
0 to 100%
<± 2% RH
1% RH
-40-248°F
0-105%
Multi-Gas IAQ Sensor Heads
Sensor Head
Gases
Range (ppm)
Accuracy of Calibration
Minimum Detection Limit (ppm)
Resolution (ppm)
Operational Temperature Range
Operational RH Range
MS1
CO CO2
0-2000 0-100
<±10 ppm +5% <±10% 1-100 ppm
10 0.2
1 0.1
32-104°F
10-90%
MS2
CO CO2 VOC
0-2000 0-100 0-20
<±10 ppm +5% <±10% 1-100 ppm <±10%
10 0.2 0.02
1 0.1 0.01
32-104°F
10-90%
The store will not work correctly when cookies are disabled.
We use cookies to make your experience better.To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies.Learn more.