Reed Instruments RINSPECT-KIT Home Inspection Kit

SKU
RINSPECT-KIT
Manufacturer:
Reed Instruments
Reed Instruments

Key Features:


R2300 Infrared Thermometer

  • Built-in laser pointer identifies target area • User selectable °F or °C • 12:1 distance to spot size ratio • Digitally adjustable emissivity • Max and Min readings • Backlit display • High and low alarms • Low battery indication and auto shut off • Includes battery

R6018 Dual Moisture Meter

  • Pin and Pinless functions detect moisture in wood and building materials (sheet rock, cardboard, plaster, concrete and mortar) • Pinless measurement depth up to 1" (25mm) • Classifies moisture status as: low, medium and high • Audible alert and Data Hold functions • Built-in measurement verification and battery check • Low battery indicator and auto shut-off • Replaceable pins • Includes pins, protective cap and battery

R5110 Non-Contact Voltage Detector

  • Suitable for receptacles or against insulated wire • Double insulated housing for increased safety • Audible (buzzer) and visual (LED) indicators • Built-in flashlight • Pocket clip • Auto shut off • Cat. IV 1000V safety rating • Includes batteries

R5210 Receptacle Tester

  • Compact design • Detects most common 3-wire receptacle issues • LED indicators identify 5 wiring faults • Status indicator chart • GFCI trip test

R1910 Temperature & Humidity Meter

  • Measures ambient temperature and relative humidity • Designed for one-handed operation • Backlit dual LCD display • User selectable °F/°C • Max, min and data hold functions • Low battery indicator and auto shut off • Includes batteries

R9940 Carrying Case

  • Hard outer shell protects items • Accommodates small to medium sized instruments • Built-in compartment stores instrument accessories • Soft interior lining • External dimensions: 8.75 x 6.5 x 2.25" (222.25 x 165.10 x 57.15mm)
$275.00

Secured and trusted checkout with

The Reed Instruments RINSPECT-KIT includes an Infrared Thermometer (R2300), Dual Moisture Meter (R6018), Non-Contact Voltage Detector (R5110), Receptacle Tester (R5210), Temperature & Humidity Meter (R1910) and Carrying Case (R9940).

R2300 Infrared Thermometer

Temperature Range-25.6 to 752°F (-32 to 400°C)
Accuracy±4°F (2°C) or ±2% rdg.
Resolution0.1°F (0.1°C)
Optical Resolution (D:S)12:1
Spectral Response8 to 14µm
Emissivity0.1 to 1.0 (Adjustable)
Response Time500ms
Backlit DisplayYes
Display HoldYes
High/Low AlarmsYes
Alarm IndicatorsYes (Beeping)
Max/MinYes
F/C SwitchableYes
Laser TypeClass II
Low Battery IndicatorYes
Power Supply9V Battery
Product CertificationsCE, ETL, RoHS
Battery LifeApprox. 10 hours (with continuous use, backlight on)
Operating Temperature32 to 104°F (0 to 40°C)
Storage Temperature-4 to 140°F (-20 to 60°C)
Operating Humidity Range<90%
Maximum Operating Altitude6561' (2000m)
Maximum Storage Altitude39370' (12000m)
Dimensions6.0 x 4.3 x 1.6" (153 x 108 x 40mm)
Weight6.5oz (185g)

 

R6018 Dual Moisture Meter

Measuring RangesPin Mode: 5 to 50% (wood); 1.5-33% (building materials)
Pinless Mode: 0 to 99.9% (wood and building materials)
Depth DetectionPin mode: 0.3" (8mm)
Pinless mode: up to 1" (25mm)
AccuracyPin Mode: ±(3% + 5 dgt.)
Resolution0.1%
Sensor TypeDual Function (Contact Pins/Pinless)
DisplayLCD Display
Data HoldYes
Audible Alert IndicatorAudible tone (increased intensity as moisture level rises)
Replaceable PinsYes
Auto Shut-offYes (after 2 mins)
Low Battery IndicatorYes
Power Supply9V Battery
Product CertificationsCE
Operating Temperature41 to 113°F (5 to 45°C)
Storage Temperature32 to 122°F (0 to 50°C)
Operating Humidity Range0 to 80%
Dimensions6.7 x 2.6 x 1.2" (170 x 65 x 30mm)
Weight4.2 oz (120g)

 

R5110 Non-Contact Voltage Detector

Voltage RangeLow voltage mode: 24 to 1000VAC
High voltage mode: 90 to 1000VAC
Frequency Range50 to 60Hz
Built-in FlashlightYes
Pocket ClipYes
AlarmYes (audio/visual)
Auto Shut-offYes (after 5 mins)
Low Battery IndicatorYes
Power Supply2 x AAA batteries
Overvoltage CategoryCAT. IV 1000V
Product CertificationsCE, ETL
Operating Temperature32 to 104°F (0 to 40°C)
Storage Temperature-4 to 122°F (-20 to 50°C)
Operating Humidity Range0 to 80%
Maximum Operating Altitude6561' (2000m)
Dimensions5.9 x 0.9 x 0.7" (150 x 23 x 18mm)
Weight1.8 oz (50g)

 

R5210 Receptacle Tester

Voltage Range110 to 125V AC
Frequency Range50 to 60Hz
Current Max15A
Receptacle Compatibility3-wire with GFCI
Product CertificationsCE, UL
Operating Temperature32 to 122°F (0 to 50°C)
Operating Humidity0 to 85%
Storage Temperature-4 to 140°F (-20 to 60°C)
Dimensions3 x 2 x 1" (75 x 51 x 25mm)
Weight1oz (23g)

 

R1910 Temperature & Humidity Meter

Temperature
Measuring Range14 to 140°F (-10 to 60°C)
Accuracy±2.0°F (1.0°C)
Resolution0.1°F/°C
Humidity
Measuring Range0 to 100% RH
Accuracy±5% RH
Resolution0.1% RH
General Specifications
DisplayDual LCD
Backlit DisplayYes
Data HoldYes
MaxYes
MinYes
Sampling Rate1 time/second
Overange IndicatorYes
Auto Shut-offYes (after 5 minutes, off)
Low Battery IndicatorYes
Power Supply3 "AAA" Batteries
Product CertificationsCE
Operating Temperature32 to 122°F (0 to 50°C)
Storage Temperature14 to 140°F (-10 to 60°C)
Operating Humidity Range10 to 80%
Dimensions6.3 x 2 x 1.1" (155 x 50 x 28mm)
Weight4.2oz (102g)

 

R9940 Carrying Case

External dimensions8.75 x 6.5 x 2.25" (222.25 x 165.10 x 57.15mm)
Write Your Own Review