PIECAL 525B Automated Thermocouple & RTD Calibrator

SKU
PIE-525B
Manufacturer:
PIECAL
PIECAL

Key Features:

  • Calibrate T/C instruments to 0.1 & 0.01 °F & °C
  • Calibrate RTD instruments to 0.1 & 0.01 °F & °C
  • Calibrate with Confidence
  • Perform Heat Treating Surveys & Accuracy Tests
  • Troubleshoot RTD Sensors & Instruments
  • Faster Calibrations
  • Easily Change T/C Types & Scale
  • Use in the Plant, Field or Shop
  • Easy-to-Read Display
  • Simple "No Tool" Battery Changes
  • Verify Resistance, Cold Junction Temperature & Output
Product Options:
$2,249.00

Secured and trusted checkout with

Moved to a new enclosure with a rubber boot, Practical Instrument Electronics, PIE, has presented the PIECAL 525B Automated Thermocouple & RTD Calibrator.

The 525B is the innovative replacement for the PIECAL 525 equipped with a tilt stand, rubber boot, backlit display and 4 “AA” batteries. The calibrator has 14 T/C types, increased from the previous 10, and additional RTD types for Platinum 10, 50, 200 & 500 Ohm for the 1.3850 (IEC 751/DIN) curve.

It also features a new efficient secondary display that shows cold junction temperature and millivolts while displaying thermocouple temperature as well as showing ohms while displaying RTD temperature.

The PIECAL 525B can automatically detect when individual wire connections are open of 2, 3 or 4 wire connections. Likewise, proper instrument operation can be verified by measuring the excitation current.

 

Screw terminal for T/C wire plus miniature T/C socket
Isothermal block with ±0.05°C Cold Junction Sensor

Banana jacks for 2, 3 & 4 wire RTD

General

Operating Temperature

Range

-20 to 60 °C (-5 to 140 °F)

Storage Temperature  Range

-30 to 60 °C (-22 to 140 °F)

Temperature effect

≤ ±25 ppm/°C of Range;

Cold Junction Sensor: ≤ ±0.01% °/° from ambient

temperature (°C or °F)

Relative Humidity Range

10 % ≤RH ≤90 % (0 to 35 °C), Non-condensing

10 % ≤RH≤ 70 % (35 to 60 °C), Non-condensing

Normal Mode Rejection

50/60 Hz, 50 dB

Common Mode Rejection

50/60 Hz, 120 dB

Size

5.63 x 3.00 x 1.60 in, 143 x 76 x 41mm (L x W x H)

Weight

12.1 ounces, 0.34 kg with boot & batteries

Batteries

Four “AA” Alkaline 1.5V (LR6)

Optional NiMh Rechargeable

battery kit

120 VAC for North America Only; charger,  four

NiMh batteries, AC & DC cords [Part # 020-0103]

Battery Life

50 Hours

Low Battery

Low battery indication with nominal 1 hour of

operation left

Protection against

misconnection

Over-voltage protection to 60 vrms (rated for 30 seconds)

Red LED indicates OVERLOAD or out of range

conditions

Display

High contrast graphic liquid crystal display. LED

backlighting for use in low lit areas.

 

Voltage Source

Ranges and Resolution

-13.000 to 80.000 mV & -13.0000 to 80.0000 mV

Accuracy

±(0.008% of Setting + 0.006 mV)

Source Current

≥ 10 mA

Output Impedance

< 0.3 Ohm

RMS Noise

≤ ± 0.0005 mV from 0.1 to 10 Hz

Short Circuit Duration

Infinite

 

Voltage Read

Range and Resolution

Same as Voltage Source

Accuracy

±(0.008% of Reading + 0.006 mV)

Input resistance

≥ 10 MΩ

 

Thermocouple Source

Accuracy

±(0.008% of Setting + 0.006 mV)

Cold Junction

Compensation

± 0.09°F (±0.05 °C) - Thermistor  traceable to NIST for 11 years

Output Impedance

< 0.3 Ohms

Source Current

> 10 mA (drives 80 mV into 10 Ohms)

RMS Noise

≤ ± 0.0005 mV from 0.1 to 10 Hz

 

Thermocouple Read

Accuracy

±(0.008% of Reading + 0.006 mV)

Cold Junction

Compensation

± 0.09°F (±0.05 °C) - Thermistor  traceable to NIST for 11 years

Input Impedance

> 10 Megohms

Open Thermocouple

Threshold: 10,000 Ohms nominal

Pulse: < 10 microamp pulse for 300 milliseconds

 

RTD and Ohms Source

3Wire & 4 Wire Accuracy

     From 1 to 10.2 mA

External Excitation Current

 

     Below 1 mA of External

Excitation Current

2Wire Accuracy

 

±(0.015% of Setting + 0.05 Ohms)

 

 

Add (          0.025 mV         ) Accuracy

         mA Excitation Current

Add 0.1 Ohms to 3 Wire & 4 Wire Accuracy

Resistance Ranges

400 Ohm Range: 0.00 to 401.00 & 0.000 to 401.000

4000 Ohm Range: 0.0 to 4010.0 & 0.00 to 4010.00

RMS Noise

400 Ohm Range: ≤ ± 0.005 Ohms from 0.1 to 10 Hz

4000 Ohm Range: ≤ ± 0.05 Ohms from 0.1 to 10 Hz

Allowable Excitation

Current Range

400 Ohm Range:10.2 mA max; steady or pulsed/intermittent

4000 Ohms Range: 1 mA max; steady or pulsed/intermittent

Pulsed Excitation

Current Compatibility

DC to 0.01 second pulse width

 

RTD and Ohms Read

Resistance Ranges

Same as RTD and Ohms Source

Accuracy

±(0.015% of Reading + 0.05 Ohms)

Excitation Current

0.9 mA to 401 Ohms, 0.4 mA to 4010 Ohms (nominal)