The MAVO-SPOT 2 USB is a precision luminance measuring instrument with a measuring angle of 1°. This meter provides luminance measurements from a distance from 1 m to infinity, while taking into consideration the ambient light. The MAVO-SPOT 2 USB is equipped with a high quality SLR optical system. It has a viewing field of 15° and clearly marked measuring angle of 1° in the center, as well as an external focusing ring. Two optional close-up lenses allow the measuring distance down to 34 cm.
Type | Luminance meter, with precision single lens reflex optical system, display in view-finder |
Measuring angle | 1 ° |
Accuracy | Class B according to DIN 5032-7 in all chapters and DIN EN 13032-1, Appendix B |
Optical system | Stray light error ambient light (fs (u) < 2%) |
Field of view | 15 ° diagonal |
Focusing distance | 1 m to ∞ - focusing with external ring at the lens |
Light sensor | Silicon photo diode with V(λ) filter (f1 < 3%) |
Luminance measuring unit | cd/m² or fL (selectable with DIP switches) |
Measuring ranges | Automatic measuring range selection 0.01 cd/m² to 99 990 cd/m² in four ranges or 0,003 fL to 29 187 fL in four ranges |
Measuring functions | Luminance in cd/m² or fL (selectable) Luminance percentage Memory MEM Correction Factor CORR Measuring the illuminance (Lux) with GOSSEN Reflexion Standard (optional accessory) |
Measuring mode | Measurement from the distance (Close-up lenses for shorter distances, optional accessories) Contact measurement (Measuring Probe for contact measurement, optional accessory) |
Data memory | Up to 1000 individual measurement values, or in 10 groups (adjustable with DIP switch in the battery compartment) |
USB Port | USB 2.0 (1.1 compatible) |
Operating elements | Easy to use with 4 buttons, 1 sliding switch Configuration with DIP switches in the battery compartment |
Operating temperature | 0° C to 50° C, According to EN 61010-1:2001, cl. 1.4.1 |
Storage temperature | -20°C to +70°C |
Power supply | 2 x 1,5 V, size AA, when connected to PC, power will be supplied via the USB cable |
Software | gLux software and additional applications |
Others | Tripod socket |
Weight | appr. 400 g without batteries |
Standard equipment | Meter in aluminum transport case, gLux software incl. meter driver, USB cable, lens cover, eye piece, batteries and instruction manual |
Optional accessories | Close-up lens 1 (51 cm to 100 cm), close-up lens 2 (34 cm to 50 cm), Measuring Probe for contact measurement, Reflexion Standard for Lux measurement, Stray light screen, Carrying strap |
For Luminance Measurement of:
- • Display monitors for computer tomography, digital radiography, viewing panels for X-ray films, and other medical systems
- • Lighting of streets, roads, tunnels, and airfields
- • Light reflections at work places according to the applicable protective laws and regulations for people at work
- • Lighting in public places, museums, and buildings
- • Projection screens, for checking the uniformity of the illumination
- • Official inspections or constancy tests in medical applications according to IEC 61223-2-5