Fluke Ti95 Fluke Connect FCA Kit - DISCONTINUED

SKU
FLK-TI95 9HZ/FCA
Manufacturer:
Fluke
Fluke

Key Features:

This Product is DISCONTINUED
Please see the Fluke TiS20 as a Recommended Replacement

The Fluke Ti95 Infrared Camera offers:

  • The only wireless industrial infrared camera in its price class – take advantage of the benefits of Fluke Connect™ by seamlessly gathering and sharing inspection results instantly
  • Superior image quality, up to 23% better spatial resolution than other competitive models in this price class
  • 80x80 resolution
  • Removable 8 GB SD Memory Card
  • 8 GB Fluke Connect™ wireless SD Card
  • Find potential problems faster and easier with IR-Fusion® picture-in-picture mode
  • 2 megapixel built-in digital camera
  • Large 3.5 inch LCD - 32% larger screen than other competitive models lets you clearly see what you are measuring
  • Smart Battery System - Lithium ion smart battery pack with five-segment LED display to show charge level
  • Rugged, lightweight, point–and–shoot infrared camera

The Fluke 3000 FC Series Wireless Multimeter offers:

  • AC and DC voltage measurements to 1000V
  • AC and DC current with 0.01 mA resolution
  • Continuity, resistance, diode test, capacitance and frequency measurements
  • MIN/MAX recording
  • CAT III 1000 V, Cat IV 600 V; IP54

The Fluke a3001 FC Wireless iFlex™ AC Current Module offers:

  • One (1) true-RMS flexible current meter
  • One (1) iFlex i2500-10 flexible current probe
  • Measure up to 2500 A AC
  • Use as a standalone meter or as part of the system
  • Logging function for recording and saving up to 65,000 readings
  • Inrush function
  • Magnetic hanging strap
Call For Price

Secured and trusted checkout with

Fluke’s Ti95 Fluke Connect FCA Kit is comprised of the Fluke Ti95 Infrared Camera, the Fluke 3000 FC DMM and Fluke a3001 FC iFlex Module. Users can execute infrared inspections while taking measurements with the a3001 FC on the 3000 FC DMM from distances of up to 20 meters away – all at the same time. Even more, measurement data can be uploaded to the Cloud using a smart phone for later analysis and collaboration of inspection results from anywhere.

 

Fluke Connect® with ShareLive™ video call is the most comprehensive software and wireless test tool family that keeps you in contact with your entire team without leaving the field. The Fluke Connect family offers the largest system of connected test tools in the world. The software is compatible with the HTC One and One M8 running Android 4.4.x or higher, LG G3 and Nexus 5 running Android 4.4.x or higher, Samsung Galaxy S4 running Android 4.3.x or higher, Samsung Galaxy S5 running Android 4.4.x or higher. It also works with the iPhone models 4S and higher running iOS 8.0 or higher, iPad Air and iPad Mini (2nd generation) in an iPhone frame on iPad and iPod Touch (5th generation) and comes with over 30 different Fluke products.  Please see our Fluke Connect category for the complete collection of Fluke Connect Products.  Take me to Fluke Connect (Click Here).

 

Save time and increase productivity in the field with Fluke Connect    

 

  • • Share images in real-time across teams with Fluke Connect
  • Save time by creating and emailing reports from the jobsite
  • Capture multiple measurements all in one report
  • WiFi upload and free storage with Fluke Cloud™
  • Store thousands of images with internal 4 GB memory and external slot

Fluke Ti95 Infrared Camera

Key Features
IFOV (spatial resolution)5.6 mRad
Resolution80 x 80 (6,400 pixels)
Field of view26° H x 26° V
Wireless connectivityYes
Fluke Connect™ app compatibleYes, with included wireless SD card (where available)
IR-Fusion® technologyPIP (46 cm (18 in) and beyond)
Focus systemFixed focus 46 cm (18 in) and beyond
Ruggedized display3.5 inch diagonal (portrait format)
Rugged, ergonomic design for one-handed useYes
Thermal sensitivity (NETD)≤ 0.10°C at 30°C target temp (100 mK)
Temperature measurement range (not calibrated below -10°C)-20°C to +250°C (-4°F to +482°F)
Level and spanSmooth auto and manual scaling
Fast auto toggle between manual and auto modesYes
Fast auto-rescale in manual modeYes
Minimum span (in manual mode)2.5°C
Minimum span (in auto mode)5°C
Built-in digital camera (visible light)2 megapixel industrial performance
Frame rate9 Hz only
Data Storage and Image Capture
Extensive SD memory systemRemovable 8 GB SD memory card and 8 GB wireless SD card (where available)
Direct download via USB-to-PC connection
Image capture, review, save mechanismOne-handed image capture, review, and save capability
File formats imageNon-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2)
No analysis software required for non-radiometric (.bmp, .jpg) files
Memory reviewThumbnail view navigation and review selection
SoftwareSmartView® software, Fluke Connect™, and SmartView® Mobile app - full analysis and reporting software
Export file formats with SmartView® softwareBMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF
Battery
Batteries (field-replaceable, rechargeable)One lithium ion smart battery pack with five-segment LED display to show charge level
Battery lifeFour+ hours continuous use per battery pack (assumes 50% brightness of LCD and average usage)
Battery charge time2.5 hours to full charge
AC battery charging systemIn-imager charging. AC mains adapters included in 9 Hz versions. Optional two-bay AC battery charger (110 VAC to 220 VAC, 50/60 Hz) or optional 12 V automotive charging adapter.
AC operationAC operation with included power supply (110 VAC to 220 VAC, 50/60 Hz). AC mains adapters included.
Power savingUser selectable sleep and power off modes
Temperature Measurement
Accuracy±2°C or 2% (at 25°C nominal, whichever is greater)
On-screen emissivity correctionYes (both number and table)
On-screen reflected background temperature compensationYes
Color Palettes
Standard palettes6: Ironbow, blue-red, high-contrast, amber, hot metal, grayscale
General Specifications
Infrared spectral band9 μm to 15 μm (long wave)
Operating temperature-10°C to +50°C (14°F to 122°F)
Storage temperature-20°C to +50°C (-4°F to 122°F)
Relative humidity10% to 95%, non-condensing
Center-point temperature measurementYes
Spot markersHot and cold spot markers
Center box (MIN-MAX-AVG)Fixed-size measurement box with MIN-MAX-AVG temp
Safety standardsCSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01
Electromagnetic compatibilityEN 61326-1:2006 IEC 61326-1:2005
C TickIEC/EN 61326-1
US FCCEN61326-1; FCC Part 5
Vibration2G, IEC 68-2-6
Shock25G, IEC 68-2-29
DropEngineered to withstand 2 meter (6.5 feet) drop
Size (H x W x L)28.4 x 8.6 x 13.5 cm (11.2 x 3.4 x 5.3 in)
Weight (battery included)0.726 kg (1.6 lb)
Enclosure ratingIP54 (protected against dust, limited ingress; protection against water spray from all directions)
WarrantyTwo-years (standard), extended warranties are available
Recommended calibration cycleTwo-years (assumes normal operation and normal aging)
Supported languagesCzech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish

 

Fluke 3000 FC Wireless Multimeter

* For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ±([ % of Reading ] + [ Number of least significant digits ]).

Detailed Specifications
AC Voltage
Range (1) / Resolution600.0 mV / 0.1 mV
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy (2) (3) (4)45 Hz to 500 Hz1.0 % + 3
500 Hz to 1 kHz2.0% + 3
(1) All AC voltage ranges are specified from 1 % of range to 100 % of range.
(2) Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
(3) For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3.
(4) Do not exceed 107 V-Hz.
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
Function
mVRange / Resolution600.0 mV / 0.1 mV
Accuracy0.09% + 2
VRange / Resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy0.09% + 2
0.15% + 2
)))Range / Resolution600 Ω / 1 Ω
AccuracyMeter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
Range / Resolution600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
60.00 kΩ / 0.1 kΩ
600.0 kΩ / 0.001 MΩ
50.00 MΩ / 0.01 MΩ
Accuracy0.5% + 2
0.5% + 1
1.5% + 3
Diode testRange / Resolution2.000 V / 0.001 V
Accuracy1% + 2
µFRange / Resolution1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF (1) / 1 μF
Accuracy1.2% + 2
10% typical
(1) In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2.
AC and DC Current
Function
mA AC
(45 Hz to 1 kHz)
Range (1) / Resolution60.00 mA / 0.01 mA
400.0 mA (3)/ 0.1 mA
Accuracy1.5% + 3
mA DC (2)Range (1) / Resolution60.00 mA / 0.01 mA
400.0 mA (3)/ 0.1 mA
Accuracy0.5% + 3
(1) All AC current ranges are specified from 5 % of range to 100% of range.
(2) Input burden voltage (typical): 400 mA input 2 mV/mA.
(3) 400.0 mA accuracy specified up to 600 mA overload.
Frequency
Range / Resolution99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 kHz
99.99 kHz / 0.01 kHz
Accuracy (1)0.1% + 1
(1) Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
Input Characteristics
FunctionOverload
protection
Input impedance
(nominal)
Common mode rejection ratio (1 kΩ unbalance)Normal mode rejection
1100 Vrms> 10 MΩ < 100 pF> 120 dB at DC, 50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz
1100 Vrms> 10 MΩ < 100 pF> 60 dB, DC to 60 Hz> 60 dB at 50 Hz or 60 Hz
1100 Vrms> 10 MΩ < 100 pF> 120 dB at DC, 50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz
Open circuit test voltageFull scale voltageTypical short circuit current
To 6 MΩ50 MΩTypical short circuit current
1100 Vrms< 2.7 VDC< 0.7 VDC< 0.9 VDC< 350 mA
1100 Vrms< 2.7 VDC2.000 VDC< 1.1 mA
mA Function
Overload protectionFused, 44/100 A, 1000 V FAST Fuse
Overload600 mA overload for 2 minutes maximum, 10 minutes rest minimum
MIN/MAX Recording Accuracy
DC functionsThe specified accuracy of the measurement function ±12 counts for changes > 350 mS in duration.
AC functionsThe specified accuracy of the measurement function ±40 counts for changes > 900 mS in duration.
General Specifications
Maximum voltage between any terminal and earth ground1000 VDC or AC rms
Ω fuse protection from A inputs0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD)Update rate4/sec
Volts, amps, ohms6000 counts
Frequency10,000 counts
Capacitance1,000 counts
Battery typeThree AA Alkaline batteries, NEDA 15A IEC LR6
Battery life250 hours minimum
RF communications2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructedUp to 20 m
Obstructed, sheetrock wallUp to 6.5 m
Obstructed, concrete wall, or steel electrical enclosureUp to 3.5 m
TemperatureOperating-10°C to 50°C
Storage-40°C to 60°C
Temperature coefficient0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
Relative humidity0% to 90% (0°C to 35°C)
0% to 75% (35°C to 40°C)
0% to 45% (40°C to 50°C)
AltitudeOperating2,000 m
Storage12,000 m
Electromagnetic compatibility
EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008,
FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
Safety complianceANSI/ISA 61010-1 / (82.02.01): 3rd edition
CAN/CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010-1: 3rd edition
IEC/EN 61010-1:2010
CertificationsCSA, FCC, CE
Ingress Protection (IP) ratingIP54
Pollution Degree2
Size (H x W x L)4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
Weight340 g (12 oz)
WarrantyThree years
Not compatible with Fluke CNX test tools

 

Fluke a3001 FC Wireless iFlex® AC Current Module

Specifications
Range0.5 A to 2500 A AC
Resolution0.1 A
Accuracy3% ±5 digits (5 Hz to 500 Hz)
Crest factor (50 Hz / 60 Hz)3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
add 2% for C.F. > 2
LCD w/backlight3½ digits
Log rate/interval1 sec minimum/adjustable by PC or front panel
Battery type2 AA, NEDA 15 A, IEC LR6
Battery life400 hours
MemoryRecord up to 65,000 readings
RF communications2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructedUp to 20 m
Obstructed, sheetrock wallUp to 6.5 m
Obstructed, concrete wall or steel electrical enclosureUp to 3.5 m
Operating temperature-10°C to +50°C
Storage temperature-40°C to +60°C
Temperature coefficientAdd 0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
Operating humidity90% at 35°C
75% at 40°C
45% at 50°C
AltitudeOperating
2,000 m
Storage12,000 m
EMCEN 61326-1:2006
Safety complianceIEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition
Safety ratingCAT IV 600 V, CAT III 1000 V
CertificationsCSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) ratingIP42
Pollution Degree2
Jaw opening25.4 cm (10 in) coil
Size (H x W x D)16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in)
Weight.22 kg (8 oz)
WarrantyThree years
Not compatible with Fluke CNX test tools