Fluke 3000 FC General Maintenance System

SKU
FLK-3000FC GM
Manufacturer:
Fluke
Fluke

Key Features:

Fluke 3000 FC Series Wireless Multimeter with the Fluke Connect™ app

  • AC and DC voltage measurements to 1000V
  • AC and DC current with 0.01 mA resolution
  • Continuity, resistance, diode test, capacitance and frequency measurements
  • MIN/MAX recording
  • CAT III 1000 V, Cat IV 600 V; IP54

Fluke v3000 FC Wireless AC Voltage Module

  • Measurements up to 1000 V true-RMS AC
  • Use as a standalone meter or as part of the system
  • A logging function for recording and saving up to 65,000 readings

Fluke v3001 FC Wireless DC Voltage Module

  • Measure up to 1000 V DC
  • Use as a standalone meter or as part of the system
  • Use the logging function for recording and saving up to 65,000 readings

Fluke a3001 FC Wireless iFlex® AC Current Module

  • Measure up to 2500 A AC
  • Use as a standalone meter or as part of the system
  • Logging function for recording and saving up to 65,000 readings
  • Inrush function
Product Options:
$1,129.99

Secured and trusted checkout with

     The 3000 General Maintenance System is part of the team of Fluke wireless troubleshooting tools. Connect the a3001 iFlex AC Wireless Current Module to your test point, and view the results up to 20 meters away on the 3000 Wireless Multimeter. Or connect the v3000 AC Wireless Voltage Module and view both voltage and current measurements simultaneously. You’ll save time, with less run-around collecting multiple measurements. Use multiple modules for measurements on three-phase systems. Or use as a stand-alone measurement tool or combine with other 3000 modules as a system for multiple measurements. From short distances, you can even view readings from modules through closed electrical panels. Plus no more writing down data as the remote modules capture up to 65,000 sets of time stamped min/max/avg readings, using the optional PC adapter. The wireless test tools also offer increased safety by letting you view readings in a separate location from the test point. Now you can take readings on moving machinery, with only the measurement module in harm’s way.

Fluke 3000 FC Series Wireless Multimeter

* For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0% to 90%. Accuracy specifications take the form of ±([% of Reading] + [Number of least significant digits]).

Detailed Specifications
AC Voltage
Range ¹ / Resolution600.0 mV / 0.1 mV
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy 2 3 445 Hz to 500 Hz1.0% + 3
500 Hz to 1 kHz2.0% + 3
1. All AC voltage ranges are specified from 1% of range to 100% of range.
2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3. For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3.
4. Do not exceed 107 V-Hz.
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
Function
mVRange / Resolution600.0 mV / 0.1 mV
Accuracy0.09% + 2
VRange / Resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy0.09% + 2
0.15% + 2
)))Range / Resolution600 Ω / 1 Ω
AccuracyMeter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
ΩRange / Resolution600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
60.00 kΩ / 0.1 kΩ
600.0 kΩ / 0.001 MΩ
50.00 MΩ / 0.01 MΩ
Accuracy0.5% + 2
0.5% + 1
1.5% + 3
Diode testRange / Resolution2.000 V / 0.001 V
Accuracy1% + 2
µFRange / Resolution1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF1 / 1 μF
Accuracy1.2% + 2
10% typical
1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2.
AC and DC Current
Function
mA AC
(45 Hz to 1 kHz)
Range 1 / Resolution60.00 mA / 0.01 mA
400.0 mA 3/ 0.1 mA
Accuracy1.5% + 3
mA DC 2Range 1 / Resolution60.00 mA / 0.01 mA
400.0 mA 3/ 0.1 mA
Accuracy0.5% + 3
1. All AC current ranges are specified from 5% of range to 100% of range.
2. Input burden voltage (typical): 400 mA input 2 mV/mA.
3. 400.0 mA accuracy specified up to 600 mA overload.
Frequency
Range / Resolution99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 kHz
99.99 kHz / 0.01 kHz
Accuracy 10.1% + 1
1 Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
Input Characteristics
FunctionOverload
protection
Input impedance
(nominal)
Common mode rejection ratio (1 kΩ unbalance)Normal mode rejection
1100 Vrms> 10 MΩ < 100 pF> 120 dB at DC, 50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz
1100 Vrms> 10 MΩ < 100 pF> 60 dB, DC to 60 Hz> 60 dB at 50 Hz or 60 Hz
1100 Vrms> 10 MΩ < 100 pF> 120 dB at DC, 50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz
Open circuit test voltageFull scale voltageTypical short circuit current
To 6 MΩ50 MΩTypical short circuit current
1100 Vrms< 2.7 VDC< 0.7 VDC< 0.9 VDC< 350 mA
1100 Vrms< 2.7 VDC2.000 VDC< 1.1 mA
mA Function
Overload protectionFused, 44/100 A, 1000 V FAST Fuse
Overload600 mA overload for 2 minutes maximum, 10 minutes rest minimum
MIN/MAX Recording Accuracy
DC functionsThe specified accuracy of the measurement function ±12 counts for changes > 350 mS in duration.
AC functionsThe specified accuracy of the measurement function ±40 counts for changes > 900 mS in duration.
General Specifications
Maximum voltage between any terminal and earth ground1000 VDC or AC rms
Ω fuse protection from A inputs0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD)Update rate4/sec
Volts, amps, ohms6000 counts
Frequency10,000 counts
Capacitance1,000 counts
Battery typeThree AA Alkaline batteries, NEDA 15A IEC LR6
Battery life250 hours minimum
RF communications2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructedUp to 20 m
Obstructed, sheetrock wallUp to 6.5 m
Obstructed, concrete wall, or steel electrical enclosureUp to 3.5 m
TemperatureOperating-10°C to 50°C
Storage-40°C to 60°C
Temperature coefficient0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
Relative humidity0% to 90% (0°C to 35°C)
0% to 75% (35°C to 40°C)
0% to 45% (40°C to 50°C)
AltitudeOperating2,000 m
Storage12,000 m
Electromagnetic compatibility
EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008,
FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
Safety complianceANSI/ISA 61010-1 / (82.02.01): 3rd edition
CAN/CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010-1: 3rd edition
IEC/EN 61010-1:2010
CertificationsCSA, FCC, CE
Ingress Protection (IP) ratingIP54
Pollution Degree2
Size (H x W x L)4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
Weight340 g (12 oz)
WarrantyThree years
Not compatible with Fluke CNX test tools

 

Fluke v3000 FC Wireless AC Voltage Module

Accuracy is specified as ±([% of reading] + [number of least significant digits]). All ranges are autoranging. Accuracy is specified from 5% to 100% of the range obtained by autoranging, from 18°C to 28°C.

Specifications
Range ¹ / Resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy 2 3 445 Hz to 500 Hz1.0% + 3
500 Hz to 1 kHz2.0% + 3
1. All AC voltage ranges are specified from 1% of range to 100% of range.
2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3. For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3.
4. Do not exceed 107 V-Hz.
General Specifications
LCD w/ backlight3½ digits, 6000 counts, updates 4/sec
Battery type2 AA, NEDA 15 A, IEC LR6
Battery life400 Hours
MemoryRecord up to 65000 readings
RF communications2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructedUp to 20 m
Obstructed, sheetrock wallUp to 6.5 m
Obstructed, concrete wall or steel electrical enclosureUp to 3.5 m
Operating temperature-10°C to +50°C
Storage temperature-40°C to +60°C
Temperature coefficient0.1 x (specified accuracy)/ °C (< 18°C or > 28°C)
Operating humidity90% at 35°C, 45% at 40°C, 45% at 50°C
AltitudeOperating2,000 m
Storage12,000 m
EMCEN 61326-1:2006
Safety complianceANSI/ISA 61010-1 / (82.02.01)3rd edition
CAN/CSA-C22.2 No 61010-1-123rd edition
UL 61010-13rd edition
IEC/EN 61010-12010
Safety ratingCAT IV 600 V, CAT III 1000 V
CertificationsCSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) ratingIP42
Pollution Degree2
Size (H x W x D)16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in)
Weight.22 kg (8 oz)
WarrantyThree years
Not compatible with Fluke CNX test tools

 

Fluke v3001 FC Wireless DC Voltage Module

Accuracy is specified for 1 year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0% to 90%. Accuracy specifications take the form of ±([% of Reading ] + [ Number of least significant digits ]).All ranges are autoranging. Accuracy is specified from the range obtained by autoranging, from 18°C to 28°C.

Voltage Specifications
Function
mVDCRange ¹ / Resolution600.0 mV / 0.1 mV
Accuracy0.09% + 3
VDCRange ¹ / Resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy0.09% + 3
Range ¹ / Resolution1000 V / 1 V
Accuracy0.15% + 2
General Specifications
LCD w/backlight3 ½ digits, 6000 counts, 4/sec update rate
Battery type2 AA Alkaline batteries, NEDA 15A, IEC LR6
Log rate/intervalAdjustable by PC from 1 sec to 1 hr, default 1 min
Battery life400 hours minimum
MemoryRecord up to 65,000 readings
RF communications2.4 GHz ISM Band
RF communication rangeOpen air, unobstructedUp to 20 m
Obstructed, sheetrock wallUp to 6.5 m
Obstructed, concrete wall or steel electrical enclosureUp to 3.5 m
Operating temperature-10°C to +50°C
Storage temperature-40°C to +60°C
Temperature coefficient0.1 x (specified accuracy)/ °C (< 18°C or > 28°C)
Relative humidity0% to 90% (0°C to 35°C), 0% to 75% (35°C to 40°C),
0% to 45% (40°C to 50°C)
EMCIEC 61236-1, Portable
Safety complianceIEC 61010-1, 600 V CAT IV / 1000 V CAT III, 3rd edition, Pollution Degree 2
CertificationsCSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) ratingIP42
Size (H x W x D)160 x 66 x 38 mm (6.3 x 2.6 x 1.5 in)
Weight0.255 kg (9 oz)
WarrantyThree years
Not compatible with Fluke CNX test tools

 

Fluke a3001 FC Wireless iFlex® AC Current Module

Specifications
Range0.5 A to 2500 A AC
Resolution0.1 A
Accuracy3% ±5 digits (5 Hz to 500 Hz)
Crest factor (50 Hz / 60 Hz)3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
add 2% for C.F. > 2
LCD w/ backlight3½ digits
Log rate/interval1 sec minimum/adjustable by PC or front panel
Battery type2 AA, NEDA 15 A, IEC LR6
Battery life400 hours
MemoryRecord up to 65,000 readings
RF communications2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructedUp to 20 m
Obstructed, sheetrock wallUp to 6.5 m
Obstructed, concrete wall or steel electrical enclosureUp to 3.5 m
Operating temperature-10°C to +50°C
Storage temperature-40°C to +60°C
Temperature coefficientAdd 0.1 x (specified accuracy) /°C (< 18°C or > 28°C)
Operating humidity90% at 35°C
75% at 40°C
45% at 50°C
AltitudeOperating2,000 m
Storage12,000 m
EMCEN 61326-1:2006
Safety complianceIEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition
Safety ratingCAT IV 600 V, CAT III 1000 V
CertificationsCSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) ratingIP42
Pollution Degree2
Jaw opening25.4 cm (10 in) coil
Size (H x W x D)16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in)
Weight.22 kg (8 oz)
WarrantyThree years
Not compatible with Fluke CNX test tools


Accessories

Fluke 3000 FC General Maintenance System

  • Fluke 3000 FC Wireless Multimeter
  • Fluke v3000 FC AC Wireless Voltage Module
  • Fluke a3001 FC iFlex AC Wireless Current Module
  • iFlex i2500-10 Flexible Current Probe
  • Fluke pc3000 FC Wireless PC Adapter and Software
  • TL224 Test Leads
  • TL175 Test Leads
  • AC175 Alligator Clips
  • AC285 Alligator Clips
  • Two (2) Magnetic Hanging Straps
  • Soft Carrying Case
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account

Products In This Series

As low as

Now $269.99

As low as

Now $399.99

As low as

Now $829.99

As low as

Now $1,459.99