Fluke Calibration 1502A (1502) Tweener PRT Readout Thermometer

SKU
1502A-156
Manufacturer:
Fluke Calibration
Fluke Calibration

Key Features:

  • Two Tweeners to choose from—reading PRTs or thermistors
  • Battery packs available
  • Best price/performance package
Product Options:
$3,750.00

Secured and trusted checkout with

One of Fluke Calibration's best-selling products is the Tweener thermometer, and there's a reason. No other company, not one, has a thermometer that comes close to the performance and features of the Tweener for anywhere near its price.

Model 1502A PRT Readout

The Model 1502A Tweener features accuracy up to +/-0.006 C. In addition, it reads both 100-ohm and 25-ohm probes, has a resolution of 0.001 C across its entire range and is the smallest unit in the industry. It also has an optional battery pack for completely portable operation.

Each Tweener is programmable to match any probe's constants for maximum linearity and accuracy. All probe constants and coefficients are programmed through simple, front-panel keystrokes. Temperature is displayed in C, F, K, or resistance in ohms.

The 1502A accurately measures the resistance of the probe and then converts the resistance to a temperature value using its built-in algorithms.

For convenience, the 1502A reads the common industrial grade IEC-751 or “385” ALPHA RTD without any programming. Enter the actual R0 and ALPHA of the individual probe for increased accuracy. For maximum accuracy, use the ITS-90 formulas. The Tweener accepts the subranges 4 and 6 through 11.

ITS-90 formulas reside in its firmware. If your probe has been calibrated for any of the subranges of the ITS-90, you simply enter the coefficients directly into the Tweener.

Each thermometer comes complete with an RS-232 interface for automation of temperature data collection, calibrations, or process control functions.  An IEEE-488 interface is available as an option.

The 1502A is calibrated digitally using the front-panel buttons. You never have to open the box to calibrate it. This calibration protocol further reduces the cost of the 1502A. It goes where you go and works the way you want it to.

Want more? There are two more Tweeners for specific applications, including the Model 1503 High Temperature PRT Readout and the Model 1504 Thermistor Readout.

With our Model 9934 Logware,  all three Tweener models may be used for real-time data acquisition. Collect data and analyze it graphically or statistically.
Additionally, Tweeners may be used as reference thermometers with our
MET/TEMP II software. 

If you want freedom from AC power in the field or on the plant floor, order Model 2502 and we'll install a DC power board in your Tweener.  Then you can connect your own 12-volt DC power or order Hart's 9313 Battery Pack. Our battery gives you three to eight hours between charges.  It includes a charger and a nylon pouch with a belt clip.

Temperature Range−200 °C to 962 °C (−328 °F to 1764 °F)
Resistance Range0 Ω to 400 Ω, auto-ranging
ProbeNominal RTPW: 10 Ω to 100 Ω
RTD, PRT, or SPRT
CharacterizationsITS-90 subranges 4, 6, 7, 8, 9, 10, and 11
IPTS-68: R0, a, d, a4, and c4
Callendar-Van Dusen: R0, a, d, and b
Resistance Accuracy
(ppm of reading)
0 Ω to 20 Ω: 0.0005 Ω
20 Ω to 400 Ω: 25 ppm
Temperature Accuracy±0.004 °C at −100 °C
±0.006 °C at 0 °C
±0.009 °C at 100 °C
±0.012 °C at 200 °C
±0.018 °C at 400 °C
±0.024 °C at 600 °C
Operating Temperature Range16 °C to 30 °C
Resistance Resolution0 Ω to 20 Ω: 0.0001 Ω
20 Ω to 400 Ω: 0.001 Ω
Temperature Resolution0.001 °C
Excitation Current0.5 and 1 mA, user selectable, 2 Hz
Measurement Period1 second
Digital FilterExponential, 0 to 60 seconds time constant (user selectable)
Probe Connection4-wire with shield, 5-pin DIN connector
CommunicationsRS-232 serial standard
IEEE-488 (GPIB) optional
Display8-digit, 7-segment, yellow-green LED; 0.5-inch-high characters
Power115 VAC (±10 %), 50/60 Hz, 1 A, nominal
230 VAC (±10 %), 50/60 Hz, 1 A, nominal, specify
Size (HxWxD)61 x 143 x 181mm (2.4 x 5.6 x 7.1 in)
Weight1.0 kg (2.2 lb.)
Probes from Fluke Calibration5615, 5627, 5626, 5628, 5622
CalibrationISO 17025-accredited calibration provided
Temperature ranges and accuracy may be limited by the sensor you use.