This Fluke 87-5 comes with NIST Traceable Calibration Certificate with Data. To select other Fluke 87-5 options click here
Specifications | ||
Voltage DC | Maximum voltage | 1000 V |
Accuracy | ±(0.05% + 1) | |
Maximum resolution | 10 µV | |
Voltage AC | Maximum voltage | 1000 V |
Accuracy | ±(0.7% + 2) True RMS | |
AC bandwidth | 20 kHz with low pass filter; 3 db @ 1 kHz | |
Maximum resolution | 0.1 mV | |
Current DC | Maximum amps | 10 A (20 A for 30 seconds maximum) |
Amps accuracy | ±(0.2% + 2) | |
Maximum resolution | 0.01 µA | |
Current AC | Maximum amps | 10 A (20 A for 30 seconds maximum) |
Amps accuracy | ±(1.0% + 2) True RMS | |
Maximum resolution | 0.1 µA | |
Resistance | Maximum resistance | 50 MΩ |
Accuracy | ±(0.2% + 1) | |
Maximum resolution | 0.1 Ω | |
Capacitance | Maximum capacitance | 9,999 µF |
accuracy | ±(1% + 2) | |
Maximum resolution | 0.01 nF | |
Frequency | Maximum frequency | 200 kHz |
Accuracy | ±(0.005% + 1) | |
Maximum resolution | 0.01 Hz | |
Duty cycle | Maximum duty cycle | 99.9% |
Accuracy | ±(0.2% per khz + 0.1%) | |
Maximum resolution | 0.1% | |
Temperature measurement | –200.0°C – 1090°C –328.0°F – 1994.0°F excluding probe | |
80 BK temperature probe | –40.0°C – 260°C –40.0°F – 500°F, 2.2°C or 2% whichever is greater | |
Conductance | Maximum conductance | 60.00 nS |
Accuracy | ±(1.0% + 10) | |
Maximum resolution | 0.01 nS | |
Diode | Range | 3 V |
Resolution | 1 mV | |
Accuracy | ±(2% + 1) | |
Duty cycle range | Accuracy | Within ±(0.2% per kHz + 0.1%) |
Environmental Specifications | ||
Operating temperature | –20°C to + 55°C | |
Storage temperature | –40°C to + 60°C | |
Humidity (without condensation) | 0% – 90% (0°C – 35°C) 0% – 70% (35°C – 55°C) | |
Operating Altitude | 2000 m | |
Safety Specifications | ||
Overvoltage category | EN 61010–1 to 1000 V CAT III, 600V CAT IV | |
Agency approvals | UL, CSA, TÜV, VDE listed | |
Mechanical and General Specifications | ||
Size | 201 x 98 x 52 mm (with holster) | |
Weight | 355 g 624 g – with holster | |
Display | Digital | 6000 counts updates 4/sec. 19,999 counts in high–resolution mode |
Analog | 32 segments, updates 40/sec | |
Frequency | 19,999 counts, updates 3/sec at > 10 Hz | |
Warranty | Lifetime | |
Battery Life | Alkaline | ~400 hours typical, without backlight |
Shock | 1 Meter drop per IEC 61010–1:2001 | |
Vibration | Per MIL–PRF–28800 for a Class 2 instrument |
Each Fluke 87V Meter includes
- 9V battery
- Test Leads
- Rubber Holster with Stand
- Manual
What is "Limited Lifetime Warranty"?
Each Fluke 20, 70, 80, 170 and 180 series DMM will be free from defects
in material and workmanship for its lifetime. As used herein, "lifetime" is
defined as seven years after Fluke discontinues manufacturing the product,
but the warranty period shall be at least ten years from date of purchase.
In what way is the warranty limited?
- It does not cover battery or fuses.
- It does not cover abuse or usage outside of specifications.
- It does not cover normal wear and tear of mechanical parts.
- It covers the LCD for 10 years only (state-of-the-art for LCDs).
- It covers original user purchaser only
Write Your Own Review