Fluke 378 FC Non-Contact Voltage True-rms AC/DC Clamp Meter with iFlex

SKU
FLUKE-378 FC
Manufacturer:
Fluke
Fluke

Key Features:

  • Measure voltage and current with your clamp jaw
  • Faster, safer testing - all without touching a live wire - using FieldSense™ technology
  • Power quality indicator shows whether equipment or power line is faulty
  • Complete 3-phase voltage and current tests in 3 quick steps
  • Full set of phase-to-ground and phase-to-phase values calculated and shown on the meter
  • Values are also displayed on your smart phone and saved to the cloud via Fluke Connect software
  • Phase rotation auto-calculated and shown on the Fluke Connect software
  • No more hand-written notes or complicated math
Product Options:
Special Price $836.99 Regular Price $929.99

Secured and trusted checkout with

Using the FieldSense technology, the Fluke 378 FC clamp meter is able to test faster and safer, all without contacting a live conductor. Through the clamp jaw you get accurate voltage and current measurements. With the PQ function the Fluke 378 FC can sense power quality issues automatically. 

 

Includes:

  • • 378 FC Non-Contact Voltage True-rms Clamp Meter
  • • iFlex flexible current probe (18 inches; 48 cm)
  • • TL224 silicone insulated test leads
  • • TP175 adjustable length test probes
  • • AC285 grounding clip (black, quantity one)
  • • TPAK magnetic hanging kit, with 9 inch (23 cm) hanging strap
  • • Premium Carrying case
  • • Quick reference guide

 

Fluke Connect

Set up and sustain preventive maintenance procedures easily using the Fluke Connect® system of wireless test tools and asset management software.

  • • Improve your ability to prevent or predict machine failures
  • • Make confident decisions with data you can trust and track
  • • Access your infrared images from anywhere, anytime with secure cloud storage
  • • Connect and collaborate with your team – even when you are in different places
  • • Provide more complete information to your maintenance teams
  • • Generate work orders that include measurements and infrared images
  • • Edit and analyze images; create and send reports from your smartphone directly from the field
General specifications
General Maximum Voltage between any Terminal and Earth Ground1000 V
BatteryType2 AA IEC LR6 alkaline
Life200 hour
DisplayDual readout
Automatic Power Off20 minutes
Electrical
AC Current: Jaw
Range999.9 A
Resolution0.1 A
Accuracy2 % ±5 digits (10 Hz to 100 Hz)
2.5 % ±5 digits (100 Hz to 500 Hz)
Crest Factor (50/60 Hz)3 @ 500 A
2.5 @ 600 A
1.42 @ 1000 A
Add 2 % for C.F. >2
AC Current: Flexible Current Probe
Range2500 A
Resolution1 A (≤2500 A) 0.1 A (≤999.9 A)
Accuracy3 % ±5 digits (5 Hz to 500 Hz)
Crest Factor (50/60Hz)3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2 % for C.F. >2
Position Sensitivity
Flexible current probeDistance from Optimumi2500-10 Flexi2500-18 FlexError
A0.5 in (12.7 mm)1.4 in (35.6 mm)± 0.5 %
B0.8 in (20.3 mm)2.0 in (50.8 mm)± 1.0 %
C1.4 in (35.6 mm)2.5 in (63.5 mm)± 2.0 %
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range999.9 A
Resolution0.1 A
Accuracy2 % ±5 digits1
[1]When using the ZERO function to compensate for offsets
AC Voltage: Field Sense
Range1000 V
Resolution1 V (≤1000V)
Accuracy≤4/0 AWG3 % ±5 digits (45 Hz to 66 Hz)
≥4/0 AWG5 % ±5 digits (45 Hz to 66 Hz)
Position wire as close as possible to jaw opening (see illustration). WirePositioning
AC Voltage: Test Leads
Range600.0 V 1000 V
Resolution0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy1 % ±5 digits (20 Hz to 500 Hz)
DC Voltage
Range600.0 V
1000 V
Resolution0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy1 % ±5 digits
mV dc
Range500.0 mV
Resolution0.1 mV
Accuracy1 % ±5 digits
Amps Frequency: Jaw
Range5.0 Hz to 500.0 Hz
Resolution0.1 Hz
Accuracy0.5 % ±5 digits
Trigger Level5 Hz to 10 Hz, ≥10 A
10 Hz to 100 Hz, ≥ 5 A
100 Hz to 500 Hz, ≥ 10 A
Amps Frequency: Flexible Current Probe
Range5.0 Hz to 500.0 Hz
Resolution0.1 Hz
Accuracy0.5 % ±5 digits
Trigger Level5 Hz to 20 Hz, ≥25 A
20 Hz to 100 Hz, ≥20 A
100 Hz to 500 Hz,≥25 A
Resistance
Range60.00 kΩ
6000 Ω
600.0 Ω
Resolution0.1 Ω (≤600.0 Ω)
1 Ω (≤6000 Ω)
10 Ω (≤60.00 kΩ)
Accuracy1 % ±5 digits
Capacitance
Range1000 μF
Resolution0.1 μF (≤100.0 μF)
1 μF (≤1000 μF)
Accuracy1 % ±4 digits
Mechanical
Size (L x W x H)274 mm x 86 mm x 47 mm
Weight (with Batteries)463 g
Jaw Opening34 mm
Flexible Current Probe Diameter7.5 mm
Flexible Current Probe Cable Length (head to electronics connector)1.8 m
Rogowski Coil Length450 mm
Environmental
Operating Temperature-10 °C to 50 °C
Storage Temperature-40 °C to 60 °C
Operating Humidity (without condensation)Non condensing (<10 °C)
≤90 % RH (10 °C to 30 °C)
≤75 % RH (30 °C to 40 °C)
≤45 % RH (40 °C to 50 °C)
Temperature CoefficientsAdd 0.1 x specified accuracy for each degree C >28 °C or <18 °C
Ingress ProtectionIEC 60529: IP30 (jaw closed)
Operating Altitude2000 m
Storage Altitude12 000 m
Electromagnetic Compatibility (EMC)
InternationalIEC 61326-1: Portable Electromagnetic Environment
IEC 61326-2-2, CISPR 11: Group 1, Class B
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class B: Equipment is suitable for use in domestic establishments and in establishments directly connected to a low voltage power supply network which supplies buildings used for domestic purposes.
Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.
Korea (KCC)Class A equipment (Industrial Broadcast & Communications Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Safety
GeneralIEC 61010-1: Pollution degree 2
MeasurementIEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V
Current Clamp for Leakage Current MeasurementsIEC 61557-13: Class 2, ≤30 A/m
Wireless Radio
Radio Frequency CertificationFCC ID: T68-FBLE IC:6627A-FBLE
Frequency Range2405 MHz to 2480 MHz
Output Power<100 mW
Radio Frequency DataRadio Frequency Data For Class A Devices
SIMPLIFIED EU DECLARATION OF CONFORMITY
Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU.