Fluke 374 FC True-RMS AC/DC Clamp Meter

SKU
FLUKE-374FC
Manufacturer:
Fluke
Fluke

Key Features:

  • Connect your meter to your smartphone with Fluke Connect Measurements
  • Read measurements on your phone at a safe distance, wearing less PPE while your meter takes all the risks
  • Record results directly to your phone and the Cloud
  • Create and share reports from the field via email, or converse in real-time with ShareLive™ video calls
  • Compatible with iFlex flexible current probe; use to expand the measurement range to 2500 A ac; provides access to large conductors in tight spaces
  • Compatible with TPAK magnetic hanging strap
  • Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
  • CAT IV 600 V, CAT III 1000 V safety rating
  • Three-year warranty
  • Soft carrying case
Product Options:
Special Price $476.99 Regular Price $529.99

Secured and trusted checkout with

The Fluke 374 FC True-RMS AC/DC Clamp Meter is ideal for advanced troubleshooting performance and recording measurements wireless via Fluke Connect

 

The Fluke 374 FC True-RMS AC/DC Clamp Meter includes:

  • Soft carrying case

  • TL75 test leads

  • Two AA Alkaline batteries

  • Coated instruction card

  • Safety information sheet

General Specifications

AC Current via Jaw

Range

600.0 A

Resolution 

0.1 A

 

Accuracy 

2% ±5 digits (10 Hz to 100 Hz)

 

2.5% ±5 digits (100-500 Hz)

 

Crest Factor (50 Hz/60 Hz)

2.5 @ 600 A

 

Add 2% for C.F. >2

 

AC Current via Flexible Current Probe

 

Range

2500 A

 

Resolution

0.1 A (≤ 600 A)

 

1 A (≤ 2500 A)

 

Accuracy

3% ±5 digits (5 – 500 Hz)

 

Crest Factor (50/60Hz)

2.5 at 1400 A

 

1.42 at 2500 A

 

Add 2% for C.F. > 2

 

Position Sensitivity

 
  

 

i2500-10 Flex

i2500-18 Flex

 

A

 

 

 

Distance from Optimum

0.5 in (12.7 mm)

1.4 in (35.6 mm)

 

Error

±0.5 %

±0.5 %

 

B

 

 

 

Distance from Optimum

0.8 in (20.3 mm)

2.0 in (50.8 mm)

 

Error

±1.0 %

±1.0 %

 

C

 

 

 

Distance from Optimum

1.4 in (35.6 mm)

2.5 in (63.5 mm)

 

Error

±2.0 %

±2.0 %

 

Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.

 

DC Current

 

Range

600.0 A

 

Resolution

0.1 A

 

Accuracy

2% ±5 digits

 

AC Voltage

 

Range

1000 V

 

Resolution

0.1 V (≤600.0 V)

 

1 V (≤1000 V)

 

Accuracy

1.5% ±5 digits (20 Hz to 500 Hz)

 

DC Voltage

 

Range

1000 V

 

Resolution

0.1 V (≤600.0 V)

 

1 V (≤1000 V)

 

Accuracy

1% ±5 digits

 

mV dc

 

Range

500.0 mV

 

Resolution

0.1 mV

 

Accuracy

1% ±5 digits

 

Resistance

 

Range

6000 Ω

 

Resolution

0.1 Ω (≤600 Ω)

 

1 Ω (≤6000 Ω)

 

Accuracy

1% ±5 digits

 

Capacitance

 

Range

1000 μF

 

Resolution

0.1 μF (≤ 100 μF)

 

1 μ F (≤ 1000 μF)

 

Accuracy

1% ±4 digits

 

Mechanical Specifications

 

Maximum voltage between any terminal and earth ground

1000 V

 

Batteries

2 AA, NEDA 15A, IEC LR6

 

Operating temperature

-10 °C to +50 °C

 

Storage temperature

-40 °C to +60 °C

 

Operating humidity -
non-condensing (< 10°C)

≤90% RH (at 10 °C to 30 °C)

 

≤75% RH (at 30 °C to 40 °C)

 

≤45% RH (at 40 °C to 50 °C)

 

Operating altitude

3000 m

 

Storage altitude

12,000 m

 

Size (L x W x H)

249 x 85 x 45 mm

 

Weight

395 g

 

Jaw opening

34 mm

 

Flexible current probe diameter

7.5 mm

 

Flexible current probe cable length
(head to electronics connector)

1.8 m

 

Safety

IEC 61010-1, Pollution Degree 2

 

IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V

 

IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V

 

IP rating

IEC 60529: IP30, non-operating

 

Radio Frequency Certification FCC ID

T68-FBLE IC:6627A-FBLE

 

Electromagnetic Compatibility (EMC)

 

International

IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2

 

CISPR 11: Group 1, Class A

 

Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.

 

Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.

 

Korea (KCC)

Class A Equipment (Industrial Broadcasting & Communication Equipment)

 

Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.

 

USA (FCC)

47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.

 

Temperature coefficients

Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C

 
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account

Products In This Series

As low as

Now $579.99

As low as

Now $659.99

As low as

Now $334.99