We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
The BK Precision BCS6402 is an 150 W single channel battery charger/simulator and precision DC power supply. The BCS6402 is optimized for testing batteries and battery-operated devices.
Note: All specifications apply to the unit after a temperature stabilization time of 15 minutes over an ambient temperature range of 23 °C ± 5 °C. Specifications are valid for single unit operation only.
Model | BCS6401 | BCS6402 | |||||
Channels | 2 | 1 | |||||
Voltage | CH1 | CH2 | ± 30 V | ||||
High | ± 15 V | 0 to 15 V | |||||
Low | ± 9 V | 0 to 9 V | |||||
Max Source / Sink Current | High | 3 A | 5 A | ||||
Low | 5 A | ||||||
Power | 45 W per channel, up to 90 W combined | 150 W | |||||
Variable Output Impedance | 0 to 1 Ω | ||||||
Load Regulation ± (% output + offset) | |||||||
Voltage | ≤ 0.01% + 2 mV | ||||||
Current | ≤ 0.05% + 1 mA | ||||||
Line Regulation ± (% output + offset) | |||||||
Voltage | ≤ 0.02% + 2 mV | ||||||
Current | ≤ 0.05% + 1 mA | ||||||
Ripple and Noise (20 Hz to 20 MHz) | |||||||
Normal Mode Voltage p-p | ≤ 3 mV | ≤ 4 mV | |||||
Normal Mode Voltage rms | ≤ 1 mV | ||||||
Normal Mode Current rms | ≤ 1 mA | ||||||
Programming Resolution | |||||||
Voltage | 1 mV | ||||||
Current | 0.1 mA | ||||||
Variable Output Impedance | 1 mΩ | ||||||
Readback Resolution | |||||||
Voltage | 1 mV | ||||||
Current | 5 A Range | 0.1 mA | |||||
5 mA Range | 100 nA | ||||||
Programming Accuracy ± (% output + offset) | |||||||
Voltage | ≤ 0.02% + 3 mV | ||||||
Current | ≤ 0.05% + 2 mA | ≤ 0.05% + 3 mA | |||||
Variable Output Impedance | ≤ 0.1% + 3 mΩ | ||||||
Readback Accuracy ± (% output + offset) | |||||||
Voltage | ≤ 0.02% + 2 mV | ≤ 0.02% + 3 mV | |||||
Current | 5 A Range | ≤ 0.05% + 0.2 mA | ≤ 0.05% + 3 mA | ||||
5 mA Range (1) | ≤ 0.05% + 2 µA | ||||||
Temperature Coefficient ± (% output + offset) / °C | |||||||
Voltage | 0.005% + 0.2 mV | 0.005% + 0.4 mV | |||||
Current | 0.005% + 0.2 mA | 0.01% + 0.2 mA | |||||
Resistance | 0.02% + 0.5 mΩ | ||||||
Output Response Time (2) | |||||||
Rise Time | Voltage | Full load | ≤ 500 µs | ≤ 150 µs | |||
No load | ≤ 500 µs | ≤ 150 µs | |||||
Current | Full load | Fast mode | ≤ 150 µs | Fast mode | ≤ 150 µs | ||
Normal mode | ≤ 10 ms | Normal mode | ≤ 10 ms | ||||
Fall Time | Voltage | Full Load (3) | ≤ 150 µs | ≤ 50 µs | |||
No load | ≤ 1 ms | ≤ 150 µs (4) | |||||
Transient Response (5) | |||||||
Time | ≤ 50 µs | ≤ 30 µs | |||||
DVM | |||||||
Measurement Range | -20 V to +20 V | -30 V to +30 V | |||||
Resolution | 1 mV | ||||||
Accuracy | 0.02% + 3 mV | ||||||
General | |||||||
Remote Sense Compensation | 1 V | ||||||
Command Response Time (6) | 5 ms | ||||||
Power Factor | 0.7 max. | ||||||
I/O Interfaces | USB (USBTMC-compliant) and LAN | ||||||
AC Line Input | 110/220 VAC ± 10%, 47 Hz to 63 Hz | ||||||
Isolation (output to ground) | 100 VDC max. | ||||||
Output Impedance (output off, typical) | Output-off state Normal | 150 kΩ | 200 kΩ | ||||
Output-off state Relay off | ≥ 1 GΩ (7) | ≥ 1 GΩ | |||||
Protection Functions | OVP/OCP/OTP/Reverse voltage protection | OVP/OCP/OTP | |||||
Maximum Rated Input Power | 500 VA | ||||||
Temperature Ratings | Operation | 32 °F to 104 °F (0 °C to 40 °C) | |||||
Storage | 14 °F to 158 °F (-10 °C to 70 °C) | ||||||
Dimensions (W x H x D) | 8.9” x 3.5” x 18.75” (226 x 88.2 x 476.26 mm) | ||||||
Weight | 19.85 lbs (9 kg) | 17.64 lbs (8 kg) | |||||
Warranty | 3 Years | ||||||
Standard Accessories | Power cord & certificate of calibration | ||||||
Optional Accessories | Rack mount kit (RK2US) | ||||||
Regulatory Compliance | |||||||
Safety | Low Voltage Directive (LVD) 2014/35/EU, EN61010-1:2010 | ||||||
Electromagnetic Compatibility | EMC Directive 2014/30/EU, EN61326-1:2013 |
(1) The current readback accuracy of the 5 mA range is measured in constant voltage mode. (2) From 10% to 90% or from 90% to 10% of total power excursion. Using positive output polarity.
(3) Fall time at full load when output is disabled.
(4) The set voltage will change to 0 V when the power supply output is 30 V.
(5) Time for output voltage to recover within 50 mV for a load change 50-100% of full load. Output speed set to Fast.
(6) Typical time required for output to begin to change following receipt of command data.
(7) Relay off function only supported for CH1.
Products In This Series