The BK Precision BCS6401 is a 90 W dual channel and dual range operation battery charger/simulator and precision DC power supply. The BCS6401 is optimized for testing batteries and battery-operated devices.
Note: All specifications apply to the unit after a temperature stabilization time of 15 minutes over an ambient temperature range of 23 °C ± 5 °C. Specifications are valid for single unit operation only.
Model | BCS6401 | BCS6402 | |||||
Channels | 2 | 1 | |||||
Voltage | CH1 | CH2 | ± 30 V | ||||
High | ± 15 V | 0 to 15 V | |||||
Low | ± 9 V | 0 to 9 V | |||||
Max Source / Sink Current | High | 3 A | 5 A | ||||
Low | 5 A | ||||||
Power | 45 W per channel, up to 90 W combined | 150 W | |||||
Variable Output Impedance | 0 to 1 Ω | ||||||
Load Regulation ± (% output + offset) | |||||||
Voltage | ≤ 0.01% + 2 mV | ||||||
Current | ≤ 0.05% + 1 mA | ||||||
Line Regulation ± (% output + offset) | |||||||
Voltage | ≤ 0.02% + 2 mV | ||||||
Current | ≤ 0.05% + 1 mA | ||||||
Ripple and Noise (20 Hz to 20 MHz) | |||||||
Normal Mode Voltage p-p | ≤ 3 mV | ≤ 4 mV | |||||
Normal Mode Voltage rms | ≤ 1 mV | ||||||
Normal Mode Current rms | ≤ 1 mA | ||||||
Programming Resolution | |||||||
Voltage | 1 mV | ||||||
Current | 0.1 mA | ||||||
Variable Output Impedance | 1 mΩ | ||||||
Readback Resolution | |||||||
Voltage | 1 mV | ||||||
Current | 5 A Range | 0.1 mA | |||||
5 mA Range | 100 nA | ||||||
Programming Accuracy ± (% output + offset) | |||||||
Voltage | ≤ 0.02% + 3 mV | ||||||
Current | ≤ 0.05% + 2 mA | ≤ 0.05% + 3 mA | |||||
Variable Output Impedance | ≤ 0.1% + 3 mΩ | ||||||
Readback Accuracy ± (% output + offset) | |||||||
Voltage | ≤ 0.02% + 2 mV | ≤ 0.02% + 3 mV | |||||
Current | 5 A Range | ≤ 0.05% + 0.2 mA | ≤ 0.05% + 3 mA | ||||
5 mA Range (1) | ≤ 0.05% + 2 µA | ||||||
Temperature Coefficient ± (% output + offset) / °C | |||||||
Voltage | 0.005% + 0.2 mV | 0.005% + 0.4 mV | |||||
Current | 0.005% + 0.2 mA | 0.01% + 0.2 mA | |||||
Resistance | 0.02% + 0.5 mΩ | ||||||
Output Response Time (2) | |||||||
Rise Time | Voltage | Full load | ≤ 500 µs | ≤ 150 µs | |||
No load | ≤ 500 µs | ≤ 150 µs | |||||
Current | Full load | Fast mode | ≤ 150 µs | Fast mode | ≤ 150 µs | ||
Normal mode | ≤ 10 ms | Normal mode | ≤ 10 ms | ||||
Fall Time | Voltage | Full Load (3) | ≤ 150 µs | ≤ 50 µs | |||
No load | ≤ 1 ms | ≤ 150 µs (4) | |||||
Transient Response (5) | |||||||
Time | ≤ 50 µs | ≤ 30 µs | |||||
DVM | |||||||
Measurement Range | -20 V to +20 V | -30 V to +30 V | |||||
Resolution | 1 mV | ||||||
Accuracy | 0.02% + 3 mV | ||||||
General | |||||||
Remote Sense Compensation | 1 V | ||||||
Command Response Time (6) | 5 ms | ||||||
Power Factor | 0.7 max. | ||||||
I/O Interfaces | USB (USBTMC-compliant) and LAN | ||||||
AC Line Input | 110/220 VAC ± 10%, 47 Hz to 63 Hz | ||||||
Isolation (output to ground) | 100 VDC max. | ||||||
Output Impedance (output off, typical) | Output-off state Normal | 150 kΩ | 200 kΩ | ||||
Output-off state Relay off | ≥ 1 GΩ (7) | ≥ 1 GΩ | |||||
Protection Functions | OVP/OCP/OTP/Reverse voltage protection | OVP/OCP/OTP | |||||
Maximum Rated Input Power | 500 VA | ||||||
Temperature Ratings | Operation | 32 °F to 104 °F (0 °C to 40 °C) | |||||
Storage | 14 °F to 158 °F (-10 °C to 70 °C) | ||||||
Dimensions (W x H x D) | 8.9” x 3.5” x 18.75” (226 x 88.2 x 476.26 mm) | ||||||
Weight | 19.85 lbs (9 kg) | 17.64 lbs (8 kg) | |||||
Warranty | 3 Years | ||||||
Standard Accessories | Power cord & certificate of calibration | ||||||
Optional Accessories | Rack mount kit (RK2US) | ||||||
Regulatory Compliance | |||||||
Safety | Low Voltage Directive (LVD) 2014/35/EU, EN61010-1:2010 | ||||||
Electromagnetic Compatibility | EMC Directive 2014/30/EU, EN61326-1:2013 |
(1) The current readback accuracy of the 5 mA range is measured in constant voltage mode. (2) From 10% to 90% or from 90% to 10% of total power excursion. Using positive output polarity.
(3) Fall time at full load when output is disabled.
(4) The set voltage will change to 0 V when the power supply output is 30 V.
(5) Time for output voltage to recover within 50 mV for a load change 50-100% of full load. Output speed set to Fast.
(6) Typical time required for output to begin to change following receipt of command data.
(7) Relay off function only supported for CH1.