We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
The BK Precision 394B is a process multimeter with an 50,000 display count. The 394B current output ranges is 0-20 mA or 4-20 mA and the loop power supply is >24 V.
Specifications are based on the following conditions/assumptions:
- • Accuracy specifications: ± (% of reading + counts of least significant digit) at 23 °C ± 5 °C, with relative humidity less than 80% RH
• One year calibration cycle
• Temperature coefficient is 0.1 x (specified accuracy)/°C for T < 18 °C, T > 28°C
• AC voltage and AC current specifications are AC coupled, true RMS
• For non-sinusoidal waveforms:
- Add 1.0% to AC accuracy specification for Crest Factor 1.4 to 2.0
- Add 2.5% to AC accuracy specification for Crest Factor 2.0 to 2.5
- Add 4.0% to AC accuracy specification for Crest Factor 2.5 to 3.0
• For best accuracy use REL (delta) function to compensate the offsets
• AC + DC accuracy: AC accuracy + DC accuracy + 1.0%
• HFR accuracy: AC accuracy + 1.0% for 40 Hz to 400 Hz.
• Overload protection: AC/DC 1000 V
Voltage
Function | Range | Accuracy |
AC (1) | 50.000 mV 500.00 mV | Sine wave: (0.7 + 20) for 40 Hz to 70 Hz (1.5 + 40) for 71 Hz to 10 kHz |
5.0000 V 50.000 V 500.00 V 1000.0 V(2) | Sine wave: (0.5 + 20) for 40 Hz to 70 Hz (1.5 + 40) for 71 Hz to 10 kHz (3.0 + 80) for 1001 Hz to 10 kHz | |
DC | 50.000 mV | 0.05 + 30 |
500.00 mV 5.0000 V 50.000 V 500.00 V 1000.0 V | 0.05 + 5 |
(1) Below 5% of AC range, add 20 digits to accuracy.
(2) The bandwidth of range is 40 Hz to 1 kHz
Notes:
- Input impedance: 10 MΩ, < 100 pF
- Min. resolution: 1 μV in 50 mV range
Current
Function | Range | Accuracy |
AC (3) | 50.000 mA 1.000 A | Sine wave: (1.0 + 20) for 40 Hz to 70 Hz (2.0 + 40) for 71 Hz to 10 kHz |
DC | 50.000 mA 1.000 A | 0.05 + 5 |
(3) Below 5% of AC range, add 20 digits to accuracy.
Notes:
- Max. continuous measuring time: 10 minutes at mA input, 1 minute at A input
- Min. rest time: 20 minutes after continuous measuring
- Input impedance: 13 Ω at mA input and 0.1 Ω at A input
- Min. resolution: 1 μA in 50 mA range
Resistance
Range | Resolution | Test Current | Accuracy |
500.00 Ω | 0.01 Ω | 1 mA | 0.2 + 30 |
5.0000 kΩ | 0.1 Ω | 100 μA | 0.2 + 10 |
50.000 kΩ | 1 Ω | 10 μA | |
500.00 kΩ | 10 Ω | 1 μA | 0.5 +10 |
5.0000 MΩ | 100 Ω | 100 nA | 1.0 + 10 |
50.00 MΩ | 10 kΩ | 10 nA | 2.0 + 10 |
Notes:
- Max. open circuit voltage: 3.5 V
Continuity
Range | Resolution | Test Current | Accuracy |
500.00 Ω | 0.01 Ω | 1 mA | 0.1 + 30 |
Notes:
- Max. open circuit voltage: 3.5 V
- Continuity threshold: < 30 Ω
Diode Test
Range | Resolution | Test Current | Accuracy |
2.000 V | 1 mV | ± 1 mA | 1.0 + 10 |
Notes:
- Max. open circuit voltage: ± 3.5 V
Frequency
Range | Resolution | Accuracy |
500.00 Hz | 0.01 Hz | ± 3 digits |
5.0000 kHz | 0.1 Hz | |
50.000 kHz | 1 Hz | |
100.00 kHz | 10 Hz |
Notes:
- Min. frequency: 5 Hz
Process Multimeter Functions / Current Output
Range | Accuracy | Resolution | Output Adjustment Modes | |
Ramp | Step | |||
0 to 20 mA or 4 mA to 20 mA (overrange up to 24 mA) | ± (0.05 + 5) | 1 μA | Linear (slow), 0% to 100% and back to 0% in 40 s Linear (fast), 0% to 100% and back to 0% in 20 s | 25% steps (coarse), 0% to 100%, 15 s for each step 25% steps (fine), 0% to 100%, 5 s for each step |
Process Multimeter Functions / Loop Power
Range | Accuracy | Drive Capability | |
Normal | 250 Ω HART | ||
50 mA | ± (0.05 + 5) | 30 V / 1.25 kΩ | 24 V / 1 kΩ |
General
Display | 5 digit / 50,000 count | |
Measurement Speed | 10 samples per second | |
Connectivity | IR-USB | |
Power | 4 x 1.5 V AA size batteries | |
Battery Life (typical) | 100 hours | |
Auto Power Off | Adjustable up to 20 minutes or never | |
Low Battery Indicator | √ | |
Overrange | OL is displayed | |
Temperature | Operating | 14 ºF to 122 ºF (-10 °C to 50 °C) at ≤ 80% relative humidity |
Storage | -4 ºF to 140 ºF (-20 °C to 60 °C) | |
Safety | Low Voltage Directive (LVD) 2014/35/EU, EN61010-1, EN61010-2-30, 600 V CAT IV / 1000 V CAT III | |
Electromagnetic Compatibility | EMC Directive 2014/30/EU, EN61326-1:2013 | |
Dimensions (W x H x D), without holster | 3.8" x 8.2" x 2" (95 mm x 207 mm x 52 mm) | |
Weight | 1.4 lbs (630 g) | |
Warranty | 3 Years | |
Standard Accessories | Test leads, protective case, optical-isolated USB cable, magnetic hanging kit, alkaline batteries |
Products In This Series