BK Precision 5491B True RMS Bench Digital Multimeter

SKU
5491B
Manufacturer:
B&K Precision
B&K Precision

Key Features:

  • Up to 50,000 count display resolution
  • Basic VDC accuracy of 0.02% for the 5491B and 0.03% for the 2831E
  • Dual display to indicate two measurements simultaneously
  • AC + DC True RMS
  • Up to 25 readings per second measurement rate
  • Built-in math functions: Rel, Max/Min, dBm, dB, %, Hold, Compare
  • CATI (1000 V)/CATII (300 V) protection
  • USB and RS232 (5491B only) interface
  • SCPI compatible
  • Rack-mountable with available accessory
  • Product Options:
    $599.00

    Secured and trusted checkout with

    The 2831E and 5491B are versatile and dependable bench-top digital multimeters suitable for applications in education, service & repair and manufacturing requiring basic and reliable measurements. Additionally, these multimeters enhance your productivity with built-in math functions and USB connectivity, features not found in other bench meters in this price category.

    The meters take typical multimeter measurements such as volts, ohms, and amps with great accuracy and stability and were designed for cost conscious users requiring a basic and dependable meter with a broad range of extra features offered at a value price.

    DC Voltage

    Resolution, Full Scale Reading and Accuracy  ± (% of reading + % of range), 23 °C ± 5 °C

     

    Model

     

    Rate

     

    Range

     

    Resolution

    Full Scale

    Reading

    Accuracy

    (1 year)

    Typical Input

    Impedance

     

     

    5491B

     

     

    Slow

    500.00 mV

    10 µV

    510.00

    0.02%+0.016% (1)

    >10 MΩ

    5.0000 V

    100 µV

    5.1000

    0.02%+0.008% (1)

    >11.1 MΩ

    50.000 V

    1 mV

    51.000

    0.02%+0.008%

    >10.1 MΩ

    500.00 V

    10 mV

    510.00

    0.02%+0.008%

    10 MΩ

    1000.0 V

    100 mV

    1010.0 (2)

    0.02%+0.008%

    10 MΩ

    (1) under REL status

    (2) 1% over-range (1010  V) is readable at 1000  V range

     

    AC Voltage

    Resolution, Full Scale Reading and Accuracy  ± (% of reading + % of range), 23 °C ± 5 °C

     

    Model

     

    Rate

     

    Range

     

    Resolution

     

    Full Scale

    Reading

    Accuracy (1 year)(1) 23 °C ± 5 °C

    20~50 Hz

    50~20 kHz

    20~50 kHz

    50~100 kHz

     

     

    5491B

     

     

    Slow

    500.00 mV

    10 µV

    510.00

    1.0%+0.08%)

    0.5%+0.06%

    1.5% + 0.1%

    3.0% + 0.3%

    5.0000 V

    100 µV

    5.1000

    1.0%+0.08%)

    0.35%+0.02%

    1% + 0.04%

    3.0% + 0.1%

    50.000 V

    1 mV

    51.000

    1.0%+0.08%

    0.35%+0.02%

    1% + 0.04%

    3.0% + 0.1%

    500.00 V

    10 mV

    510.00

    ----

    0.5%+0.03%

    1% + 0.04%

    3.0% + 0.1%

    750.0 V

    100 mV

    757.5(3)

    ----

    0.5%+0.03%

    1% + 0.04% (2)

    3.0% + 0.1% (2)

    Max. crest factor: 3.0 at full scale

    (1) Specifications are for sine wave inputs >5% of range.

    (2) Limit at 40 kHz or 3×107 Volt-Hz for 750 V range

    (3) 1% over-range (757.50V)  is readable at 750V  range

     

    DC Current

    Resolution, Full Scale Reading and Accuracy  ± (% of reading + % of range), 23 °C ± 5 °C

     

    Model

     

    Rate

     

    Range

     

    Resolution

    Full Scale

    Reading

    Accuracy

    (1 year)

    Burden Voltage(1)

    & Shunt Resistor

     

     

    5491B

     

     

    Slow

    5.0000 mA

    0.1 µA

    5.1000

    0.05%+0.01% (2)

    <0.6 V / 100 Ω

    50.000 mA

    1 µA

    51.000

    0.05%+0.008% (2)

    <0.06 V / 1 Ω

    500.00 mA

    10 µA

    510.00

    0.05%+0.008%

    <0.6 V / 1 Ω

    5.0000 A

    100 µA

    5.1000

    0.25%+0.01%

    <0.1 V / 10 mΩ

    20.000 A

    1 mA

    21.000 (3)

    0.25%+0.01%

    <0.6 V / 10 mΩ

    (1) Typical voltage across the input terminals at full scale reading.

    (2) Use REL function

    (3) In 20 A range, >10~20 ADC is readable for 20 seconds maximum

     

    AC Current (True RMS, AC Coupling)

    Resolution, Full Scale Reading and Accuracy  ± (% of reading + % of range), 23 °C ± 5 °C

     

    Model

     

    Rate

     

    Range

     

    Resolution

     

    Full Scale

    Reading

    Accuracy (1 year)(1) 23 °C ± 5 °C

    20~50 Hz

    50~2 kHz

    2~20 kHz

     

     

    5491B

     

     

    Slow

    5.0000 mA

    0.1 µA

    5.1000

    1.5%+0.16%

    0.5%+0.08%

    2%+0.16%

    50.000 mA

    10 µA

    51.000

    1.5%+0.16%

    0.5%+0.08%

    2%+0.12%

    500.00 m A

    100 µA

    510.00

    1.5%+0.16%

    0.5%+0.08%

    2%+0.12%

    5.0000 A

    1 mA

    5.1000

    2.0%+0.16%

    0.5%+0.1%

    ----

    20.000 A

    10 mA

    21.000 (2)

    2.0%+0.16%

    0.5%+0.1%

    ----

    Max. crest factor: 3.0 at full scale

    (1) Specifications are for sine wave inputs >5% of range.

    (2) In 20 A range,>10~20 A AC is readable for 20 seconds maximum

     

    Resistance

    Resolution, Full Scale Reading and Accuracy  ± (% of reading + % of range), 23 °C ± 5 °C

     

    Model

     

    Rate

     

    Range (1)

     

    Resolution

    Full Scale

    Reading

     

    Test current

    Accuracy

    (1 year)

     

     

     

    5491B

     

     

     

    Slow

    500.00 Ω

    10 mΩ

    510.00

    0.5 mA

    0.10%+0.01% (2)

    5.0000 kΩ

    100 mΩ

    5.1000

    0.45 mA

    0.10%+0.008% (2)

    50.000 kΩ

    1 Ω

    51.000

    45 µA

    0.10%+0.008% (2)

    500.00 kΩ

    10 Ω

    510.00

    4.5 µA

    0.10%+0.008%

    5.0000 MΩ

    100 Ω

    5.1000

    450 nA

    0.15%+0.008%

    50.000 MΩ

    1 kΩ

    51.000

    45 nA

    0.3%+0.01%

    (1) In order to eliminate the noise interference, which might be induced to the test leads, it is recommended  to use a shielded test cable

    for measuring resistance above 100 kΩ.

    (2) Using REL function

     

    Continuity

    Resolution, Full Scale Reading and Accuracy  ± (% of reading + % of range), 23 °C ± 5 °C

     

    Model

     

    Range

     

    Resolution

    Full Scale

    Reading

     

    Test current

    Accuracy (1 year)

    23 ºC ± 5 ºC

    5491B

     500 Ω

     100 mΩ

     999.9

     0.5 mA

     0.1%+0.04%

    Open circuit voltage: <5.5 VDC

    Test current: around 0.5 mA DC

     

    Diode

    Resolution, Full Scale Reading and Accuracy  ± (% of reading + % of range), 23 °C ± 5 °C

     

    Rate

     

    Range

     

    Resolution

    Full Scale

    Reading

     

    Test current

    Med

    2.0000 V

    100 µV

    2.3000 V

    0.5 mA (Approx.)

     

    Frequency

    Resolution, Full Scale Reading and Accuracy  ± (% of reading + % of range), 23 °C ± 5 °C

    ACV

    Range

    Frequency

    Range

    Best

    Resolution

    Full Scale

    Reading

     

    Accuracy

    Input Sensitivity

    (Sine Wave)

     

    200 mV (500 mV*) to 750V

    10 Hz

    100 µHz

    9.9999

    0.05%+0.02%

    200 mV rms

    10~100 Hz

    1 mHz

    99.999

    0.01%+0.02%

    300 mV rms

    100~100 kHz

    10 mHz

    999.99

    0.01%+0.008%

    300 mV rms

    100k~1 MHz

    10 Hz

    999.99

    0.01%+0.008%

    500 mV rms

    * Model 5491B

     

    Period

    Resolution, Full Scale Reading and Accuracy  ± (% of reading + % of range), 23 °C ± 5 °C

    ACV

    Range

    Frequency

    Range

    Best

    Resolution

    Full Scale

    Reading

     

    Accuracy

    Input Sensitivity

    (Sine Wave)

     

    200 mV (500 mV*) to 750V

    1~10 µs

    0.1 ns

    9.9999

    0.01%+0.008%

    500 mV rms

    10 µs~10 ms

    1 ns

    9.9999

    0.01%+0.008%

    300 mV rms

    10 ms~100  ms

    1 µs

    99.999

    0.01%+0.02%

    300 mV rms

    100 ms

    10 µs

    199.99

    0.05%+0.02%

    200 mV rms

    * Model 5491B

     

    General

    Power Supply

    Power

    Consumption

    Operating

    Environment

    Storage

    Environment

     

    Warm-up

    Dimensions (W×H×D)

    Net Weight

    110/220  V ± 10%,

    50/60 Hz ± 5%

     

    10VA

    0 °C to 40 °C,

    90 %RH

     

    -40 °C to 70 °C

     

    at least 30 minutes

    225 mm×100 mm×355 mm

    8.85” x 3.93 “ x 13.97”

    2.5 kg

    5.51 lbs

    One Year Warranty (2831E), Three Year Warranty (5491B)

    Accessories Included: Test leads, Power cord, Spare fuse, Operation  Manual , Calibration certificate and test report

    Write Your Own Review
    Only registered users can write reviews. Please Sign in or create an account

    Products In This Series

    As low as

    Now $480.00