We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
The 2532B Digital Storage Oscilloscope delivers essential features and reliable performance at a price you can afford. Analog style knobs and controls combined with a smart Auto set function make this oscilloscope easy to use. Advanced triggering, automatic measurements, and FFT functions provide you with many options to debug your circuits. Educators can appreciate the ability to disable the Auto button that would automatically setup the scope to display a signal, requiring the user to learn how to set up scope parameters manually. Additionally, the instrument comes with PC software that lets you easily capture, analyze, and document waveforms and measurement results. The 2532B is an ideal education and training tool, and also well-suited for applications in service and repair.
Model | 2530B | 2532B |
Performance Characteristics | ||
Bandwidth | 25 MHz | 40 MHz |
Real Time Sampling Rate | Single Channel: 500 MSa/s Dual Channel: 250 MSa/s (for timebase faster than 250 ns/div) | |
Channels | 2 | |
Rise time | <14 ns | <8.8 ns |
Record Length | 32,000 points when time base is 50 ns or 25 ns at maximum data depth (16,000 points for 50 s - 100 ns time base), 16,000 points for dual channel operation | |
Vertical Resolution | 8 bit | |
Vertical Sensitivity | 2 mV/div -10 V/div(1-2-5 order) | |
DC Gain Accuracy | <±3.0%: 10 mV/div to 10 V/div in Fixed Gain Ranges <±4.0%: 2 mV/div ,5 mV/div and Variable Gain Ranges | |
Maximum input voltage | 400 V (DC+AC pk-pk, 1 MΩ input impedance, X10), CAT I | |
Position Range | 2 mV–100 mV: ±2 V 102 mV - 5 V: ±40 V | |
Horizontal Scan Range | 25 ns/DIV - 50 s/DIV Scan mode: 100 ms/DIV - 50 s/DIV (1 - 2.5 - 5 sequence) | 10 ns/DIV - 50 s/DIV Scan mode: 100 ms/DIV - 50 s/DIV (1 - 2.5 - 5 sequence) |
Timebase Accuracy | ±100 ppm measured over 1ms interval | |
Input Coupling | AC, DC, GND | |
Input Impedance | 1 MΩ±2% || 16 pF±3 pF | |
Vertical and Horizontal Zoom | Vertically or horizontally expand or compress a live or stopped waveform | |
I/O interface | USB host port on front panel supports USB flash drives RS-232 and USB device port for connection to PC Pass/Fail output | |
Acquisition Modes | ||
Sample | Display sample data only | |
Peak Detect | Capture the maximum and minimum values of a signal | |
Average | Waveform averaged, selectable from 4, 16, 32, 64, 128, 256 | |
Scan Mode | For time base settings 0.1 s/div - 50 s/div | |
Trigger System | ||
Trigger Types | Edge, Pulse Width, Video*, Slope, Alternating
*Support signal Formats: PAL/SECAM, NTSC Trigger condition : odd field, even field, all lines, or line number | |
Trigger Modes | Auto, Normal, Single | |
Trigger Coupling | AC, DC, LF reject, HF reject | |
Trigger Source | CH1, CH2, EXT, EXT/5, AC Line | |
Pulse Width Trigger | Trigger Modes: (>,<,=) Positive Pulse Width, (>,<,=) Negative Pulse Width | |
Slope Trigger | (>,<,=) Positive slope, (>,<,=) Negative slope Time: 20 ns -10 s |
Hardware Frequency Counter | |
Reading Resolution | 6 Bytes |
Accuracy | ±0.01% |
Range | DC Couple, 10 Hz to 25 MHz |
Signal Types | All trigger signals (except pulse width trigger and video trigger) |
Waveform Math and Measure | |
Math operation | Add, Subtract, Multiply, Divide, FFT |
FFT | Window mode: Hanning, Hamming, Blackman, Rectangular Sampling points: 1024 |
Measure | Amplitude, Average, Base, Burst Width, Cyclic RMS, + Duty Cycle, - Duty Cycle, Fall Time, Frequency, Max, Mean, Min, Rise Overshoot, Fall Overshoot, Rise Preshoot, Fall Preshoot, Peak-Peak, Period, Phase, Rise Time, RMS, Top, + Width, - Width, plus 8 advanced parameters for edge to edge timing measurements |
Display System | |
Display | 5.7 in. Color TFT, 320 x 240 resolution, 64K color |
Display Contrast (Typical state) | 150:1 |
Backlight Intensity (Typical state) | 2 300 cd/m |
Display Area | 8 x 12 div |
Display Mode | Dots, Vector |
Persistence | Off, 1 sec, 2 sec, 5 sec, Infinite |
Menu Display Timer | 2 sec, 5 sec, 10 sec, 20 sec, Infinite |
Screen-Saver | Off, 1 min, 2 min, 5 min, 10 min, 15 min, 30 min, 1 hour, 2 hour, 5 hour |
Waveform interpolation | Sin(x)/x, Linear |
Display Color Mode | Normal , Invert |
Power Requirements | 100-240 VAC, CAT II, 50 VA max, 45 Hz to 440 Hz |
Environment | |
Temperature | Operating: 50° F to 104 °F (10 °C to 40 °C) Not operating: -4 °F to 140 °F (-20 °C to 60 °C) |
Humidity | Operating: 85% RH, 104 °F (40 °C) Not operating: 85% RH, 149 °F (65 °C) |
Altitude | Operating: 9,842 ft (3,000 m) Not operating: 50,085 ft (15,266 m) |
General | |
Dimension (WxHxD) | 12 x 6.3 x 5.2 inches (305 x 160 x 133 mm) |
Weight | 5 lbs. (2.3 kg) |
Warranty | |
2530B | One Year |
2532B | Three Years |
Included accessories: User Manual, 10:1 Probe Set (2 pieces), Power Cord, USB Interface Cable, EasyScope Software Installation Disk |