Wika Mensor CTB9400 Liquid Temperature Calibration Bath (28 C ... 300 C)

SKU
CTB9400
Manufacturer:
Wika Mensor
Wika Mensor

Key Features:

  • Temperature range: 28 ... 300 °C (82.4 ... 572 °F)
  • Controller with 5.7" colour touchscreen and menu navigation in 11 languages
  • 2 x USB (host, device), Ethernet and RS-232 interface
  • High-accuracy, reliable temperature control
  • 5-point calibration for control sensors (optional)
Product Options:
$9,693.00

Secured and trusted checkout with

Wika Mensor’s CTB9400 Liquid Temperature Calibration Bath is the perfect temperature source for the calibration of temperature probes, both in the workshop and the laboratory. With a 28 ... 300 °C (82.4 ... 572 °F) temperature range, the CTB9400 is suited for a variety of applications. The calibration baths offers a temperature-controlled tank with a usable depth of 200 mm (7.87"). The maximum immersion depth for the test items of 200 mm (7.87") reduces heat dissipation errors, resulting in smaller measurement uncertainties.
Model CTB9400Model CTB9500
Temperature range28 … 300 °C-45 … +200 °C
Stability0.02 K
Display resolution0.1 °C, (0.01 °C only on exclusive version)
Display units°C/°F - selectable
Voltage supply
Power supplyAC 230 V, 50/60 Hz
AC 400 V, 50 Hz, 3~
AC 208 V, 60 Hz, 2~
AC 230 V, 50/60 Hz
AC 208 V 60 Hz, 2~
Power consumption
Current supplymax. 14 A
Current supply with 3-phase supplymax. 11 A
Fuse16 A
Fuses with 3-phase3 x 16 A
Heating power
at 230 V AC3,000 W
Cooling power
at 20 °C---800 W
at 0 °C---800 W
at -20 °C---500 W
Communication
InterfaceUSB, Ethernet, RS-232
Selectable user languagesEN, DE, FR, IT, ES, RU, CN, PT, JP, CZ, PL
Bad dimensions
Minimum filling volume11.5 litresapprox. 22 litres
Bath opening, W x D270 x 145 mm280 x 280 mm
Bath depth200 mm200 mm
Dimensions, W x D x H335 x 382 x 433 mm420 x 565 x 719 mm
Weight (empty)22 kg72 kg

 

AccessoriesModel CTB9400Model CTB9500
Silicone oil DC 200.05
-40 ... +130 °C, FP = 133 °C
Not recommendedFrom -40 … +130 °C usable
Silicone oil DC 200.10
-35 ... +160 °C, FP = 163 °C
Not recommendedFrom -35 … +160 °C usable
Silicone oil DC 200.20
10 ... 220 °C, FP = 232 °C
From 40 … 220 °C usableFrom 10 … 200 °C usable
Silicone oil DC 200.50
25 ... 250 °C, FP = 280 °C
From 40 … 250 °C usableFrom 25 … 200 °C usable
Mounting fixturesXX
USB interface cableXX

 

CE conformity
EMC directive2004/108/EC, EN 61326 Emission (group 1, class A) and interference immunity (controlled
electromagnetic environment)
Low voltage directive2006/95/EC, EN 61010-1, EN 61010-2-010
Machinery directive2006/42/EC, EN 378-2

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
  • Calibration in laboratories and in control and instrumentation workshops
  • Calibration of short temperature sensors, particularly in the pharmaceutical and food industries
  • Simultaneous calibration of several sensors