We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
User friendly, the Wika Mensor CTB9100-225 is a micro temperature calibration bath that functions with a temperature-controlled liquid tank with a practical working range of Ø 60 x 150 mm (2.36 x 5.91 in) depth. The CTB9100-225 covers a temperature range from 40 ... 225 °C (104 ... 437 °F), optionally 255 °C (491 °F). Need multiple sensors calibrated simultaneously? The Wika Mensor CTB9100-225 can handle that, making it the perfect solution for field temperature. Have an odd or short sensor? No problem, the CTB9100 accommodates a variety of different sensor sizes without the hassle of hauling around multiple metal inserts. Calibration work taking too long? The ambient to 50°C is typically 30 minutes so you can get your calibration work done rapidly. The bath boasts a high accuracy of 0.3 °K and a bath stability of 0.05°K while the internal memory can be programmed for as many as 4 quick set points making routine test points available with one touch. The bath comes equipped with a screw on lid keeping the bath fluid snug and in place during travel or transport. The optional magnetic stirrer ensures the bath stability is constant and provides the user with adjustable speed control. The bath uses common silicone oil which is available as an option, call for pricing.
Model CTB9100-165 | Model CTB9100-225 | |
Display | ||
Temperature range | -35 ... +165 °C (-31 ... +329 °F) | 40 ... 225 °C (104 ... 437 °F); optionally 40 ... 255 °C (104 ... 491 °F) |
Accuracy 1) | ±0.2 K | ±0.3 K |
Stability 2) | ±0.05 K | |
Resolution | 0.1 °C | |
Temperature distribution | ||
Axial homogeneity 3) | dependent on temperature, temperature probes and their quantity | |
Radial homogeneity 4) | dependent on temperature, temperature probes and their quantity | |
Temperature control | ||
Heating time | approx. 45 min from 20 °C to 160 °C (from 68 °F to 320 °F) | approx. 10 min from 20 °C to 225 °C (from 68 °F to 437 °F) |
Cooling time | approx. 30 min from +20 °C to -20 °C (from +68 °F to -4 °F) | approx. 30 min from 225 °C to 50 °C (from 437 °F to 122 °F) |
Stabilisation time 5) | dependent on temperature and temperature probe | |
Tank | ||
Insertion depth | 150 mm (5.91 in) | |
Volume | approx. 0.6 litres | |
Tank dimensions | Ø 60 x 165 mm (Ø 2.36 x 5.91 in) | |
Voltage supply | ||
Power supply | AC 100 ... 240 V, 50/60 Hz | AC 230 V, 50/60 Hz (AC 115 V, 50/60 Hz) 6) |
Power consumption | 375 VA | 1,000 VA |
Fuse | 6.3 A slow blow fuse | 10 A slow blow fuse (at AC 110 V) 6.3 A slow blow fuse (at AC 230 V) |
Power cord | AC 230 V; for Europe | |
Communication | ||
Interface | RS-485 | |
Case | ||
Dimensions (W x D x H) | 215 x 305 x 425 mm (8.46 x 12.00 x 16.73 in) | 150 x 270 x 400 mm (5.91 x 10.63 x 15.75 in) |
Weight | 12 kg (26.5 lbs) | 7.9 kg (17.5 lbs) |
1) Is defined as the measuring deviation between the measured value and the reference value.
2) Maximum temperature difference at a stable temperature over 30 minutes.
3) Maximum temperature difference at 40 mm (1.57 in) above the bottom.
4) Maximum temperature difference between the bores (all thermometers inserted to the same depth).
5) Time before reaching a stable value.
6) AC 115 V power supply must be specified on the order, otherwise an AC 230 V one will be delivered.
Write Your Own Review
- Calibration in the pharmaceutical industry and in the food industry
- Calibration of short temperature sensors on site
- Simultaneous calibration of several sensors
- Calibration of odd shaped sensors
- Fully portable for field calibration services