UEI DT302 Dual Input Digital Logging Thermometer

SKU
DT302
Manufacturer:
UEI
UEI

Key Features:

  • Dual Thermocouple input
  • Differential T1-T2
  • Temp range -346 to +2192F (J)
  • Temp range -328 to +2498F (K)
  • Data logging
  • 9,999 Memory positions
  • USB interface (software included)
  • Thermocouple temperature offset
  • MIN, MAX, AVG & Hold
  • Probe Storage
  • Accepts J, K, T and E type probes
  • 5 year limited warranty
  • Safety Compliance: IP67
  • Water submersion (3’ for 30 min.)
  • High pressure dust resistant (max depression of 20 mbar for 8 hours)
  • CAT 1 Overvoltage
  • CE Certified
Product Options:
$195.25

Secured and trusted checkout with

UEI DT302 Dual Thermocouple input, Differential T1-T2, Temp range -346 to +2192F (J), Temp range -328 to +2498F (K), Data logging, 9,999 Memory positions, USB interface (software included), Thermocouple temperature offset, and MIN, MAX, AVG & Hold
Measurement RangeJ-Type: -346° to +2192°F (-210° to +1200°C)
K-Type: -328° to +2498°F (-200° to +1370°C)
T-Type: -418° to +752°F (-250° to +400°C)
E-Type: -238° to +1832°F (-150° to +1000°C)
Display Resolution0.1°F/°C < 1000°
1.0°F/°C ≥ 1000°
AccuracyJ, K, T, and E-Type; ±[0.1% +1.0°F (0.5°C)]
[Below -148°F (-100°C): add 0.2% of reading
for J, K, and E-Type; and 0.1% of reading for T-Type]
Temperature
Coefficient
0.01% of reading 0.1°F per °F(+0.05°C per °C)
for <+64°F (+18°C) or +82°F (+28°C)
[Below -148°F (-100°C): add 0.05% of reading
for J, K, and E-type; and 0.1% of reading for T-type]
Real Time
Clock Tolerance
About 1 second per day
Maximum Differential
Common Mode
Voltage
1V (maximum voltage difference between any pair of inputs)
Temperature ScaleITS-90 (International Temperature Scale of 1990)
Applicable StandardsN.I.S.T. Monograph 175 revised to ITS-90
Dimension7.20” (H) x 3.70” (W) x 1.70” (D)
WeightApprox. 16.2 oz
Battery2 x LR03 (AAA) type 1.5V
CertificationCE
SafetyIEC 1010-1 (2001), UL 3111-1 (6, 1994),
EN 61010-1 (2001), CSA C22.2
No. 1010.1 (1992)
CAT IOver Voltage (Installation) CATEGORY I,
Pollution Degree 2 per IEC 1010-1
ComplianceIEC 60529: IP67 (Ingress Protection rating)
Water Immersion (3’ up to 30 min)
No ingress of dust (20mBar up to 8 hrs.)
Accuracy is specified for ambient temperatures between 64°F (18°C)
and 82°F (28°C) for a period of 1 year. The above specifications do not
include thermocouple error.
Calibration
The Apollo Digital Thermometer’s annual calibration, starting one year
after purchase, is recommended to ensure that the
thermometer performs to its accuracy specifications.

 

Includes:

  • K type Temperature Probes  2(ATT39)
  • Batteries 2(AAA)
  • Quick Start Guide
  • Owners Manual
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account