UEI DL419 1000A AC/DC True RMS Clamp Meter

SKU
DL419
Manufacturer:
UEI
UEI

Key Features:

  • True RMS
  • LRA Inrush current measurement
  • 1000A  AC/DC
  • 1000V AC/DC
  • Data hold
  • Min / Max
  • 2 Year limited warranty
Product Options:
$256.25

Secured and trusted checkout with

The UEI DL419 1000A AC/DC True RMS Clamp Meter features LRA Inrush current measurement, Data hold, Min/Max, Relative/DC A Zero mode, High contrast backlit display, Auto/ Manual ranging, Magnetic mount, Bargraph, Auto power off, and a 2-Year limited warranty.

AC Volts Measurement

RangeResolutionAccuracyOverload Protection
400mV0.1mV

 

 

± (2.0% + 5 digits)

 

 

1000V RMS

4V1mV
40V10mV
400V100mV
1000V1V

True RMS: 45Hz to 400Hz

DC Volts Measurement

RangeResolutionAccuracyOverload Protection
400mV0.1mV

 


± (0.5% + 4 digits)

 

 

1000V

4V1mV
40V10mV
400V100mV
1000V1V± (0.8% + 10 digits)

True RMS: 45Hz to 400Hz

Resistance: < 40MΩ

RangeResolutionAccuracyOverload Protection
400Ω0.1Ω

 

 

± (1.0% + 4 digits)

 

 

 

600V RMS

4kΩ
40kΩ10Ω
400kΩ100Ω
4MΩ1kΩ
40MΩ10kΩ± (2.0% + 4 digits)

Capacitance (MFD)

RangeResolutionAccuracyOverload Protection
40.00nF0.01nF

 

 

 

± (3.5% + 6 digits)

 

 

 

600V RMS

400.0nF0.1nF
4.000uF0.001μF
40.00uF0.01μF
400.0uF0.1μF
2000uF1μF

Continuity

Overload ProtectionOpen Circuit Voltage
600V RMS< 0.44V

Threshold Approx : < 40Ω

DC Low Amps Measurement -Test lead input

RangeResolutionAccuracyOverload Protection
400μA0.1μA± (1.2% + 3 digits)2000μA / 600V RMS
2000μA1μA

True RMS: 45Hz to 400Hz (Crest factor < 3 : 1 )

AC Low Amps Measurement -Test lead input

RangeResolutionAccuracyOverload Protection
400μA0.1μA± (2.0% + 5 digits)2000μA / 600V RMS
2000μA1μA± (1.5% + 5 digits)

True RMS: 45Hz to 400Hz (Crest factor < 3 : 1 )

Diode Test

Overload ProtectionRangeTest CurrentOpen Circuit Voltage
600V RMS2.0VAppx. 0.25mA< 1.6V DC

DC Amps Measurement

RangeResolutionAccuracyOverload Protection
40A0.01A± (2.5% + 15 digits)

 

1000V RMS

400A0.1A± (1.5% + 8 digits
1000A1A± (1.5% + 8 digits)

True RMS: 45Hz to 400Hz

AC Amps Measurement

RangeResolutionAccuracyOverload Protection
40A0.01A± (2.9% + 15 digits)

 

1000V RMS

400A0.1A± (1.9% + 8 digits)
1000A1A± (1.9% + 8 digits)

True RMS: 45Hz to 400Hz

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
  • Measure linear electrical loads
  • Control voltage or system board voltage checks
  • Circuit continuity or specified resistance
  • Motor run or start faults
  • Quick check of live wires
  • Diode test malfunctions/ unbroken paths
  • Motor inrush