We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
Temperature - Type K TC | |
---|---|
Measuring range | -58° to 1112 °F / -50 to +600 °C |
Accuracy | ±(0.9 °F + 0.5 % of mv) / ±(0.5 °C + 0.5 % of mv) |
Resolution | 0.1 °F / 0.1 °C |
Temperature - Infrared | |
---|---|
Measuring range | -22 to 1112 °F / -30 to +600 °C |
Accuracy | ±4.5 °F (-22.0° to -4.2 °F) / ±2.5 °C (-30.0 to -20.1 °C) ±2.7 °F (-4.0° to 31.8 °F) / ±1.5 °C (-20.0 to -0.1 °C) ±1.8 °F (32.0° to +211.8 °F) / ±1.0 °C (0.0 to +99.9 °C) ±1 % of mv (Remaining Range) |
Infrared resolution | 0.1 °F / 0.1 °C |
Humidity - Capacitive | |
---|---|
Measuring range | 0 to 100 %rH |
Accuracy | ±2 %rH ±0.9 °F / ±0.5 °C |
Resolution | 0.1 °F / 0.1 °C 0.1 %rH 0.1 °Ctd |
General technical data | |
---|---|
Dimensions | 8 x 7 x 2 in. / 193 x 166 x 63 mm |
Operating temperature | -4° to 122 °F / -20 to +50 °C |
Housing | ABS + PC |
Laser spot | on / off |
Emissivity table | 20 values |
Standards | EN 61326-1:2006 |
Alarmsignal | audible; rpm - Optical |
Auto-off backlight | 30 sec* |
Auto-off instrument | 120 sec* |
Battery type | 3 AA Batteries (or USB operating with PC-Software) |
Battery life | 25 h (typical 25°C without laser and backlight) 10 h (typical 25°C without backlight) |
Display type | Dot Matrix |
Memory | 200 measuring values |
Storage temperature | -22° to 122 °F / -30 to +50 °C |
Weight | 18 oz. / 514 g |
*disabled for continuous measurement and USB connection
- Fast detection of thermal bridges by scanning the walls, even at great distances
- Measurement of the dewpoint, dewpoint distance and aw value (surface moisture) to assess conditions of the room and wall
- Saving the data for documentation and comparison with previous measurements in order to evaluate corrective measures