Simpson Falcon F35 Series 3-1/2 Digit AC Voltage Digital Panel Meter

SKU
F35-ACV
Manufacturer:
Simpson
Simpson

Key Features:

  • Full 3-1/2 Digit, Bright Red 0.56" (14.2mm) Display
  • Broad Range Display Scaling
  • Short 2.94" (74.7mm) Deep, 1/8 DIN Case
  • Screw Terminal Connector for Easy Installation
  • Four User-Settable Ranges: 200mV, 2V, 20V, 200V
  • Jumper-Selectable Decimal Point
  • Optional Isolated 9-32VDC Power Supply
Product Options:

Maximum 25 characters

$274.44

Secured and trusted checkout with

The Simpson Falcon Series digital indicators are premium quality 1/8 DIN meters for industrial applications. All Falcon units feature jumper selectable decimal point (internal and on the connector for remote decimal point) and display scaling, providing wide application flexibility. In addition, signal input ranges are easy to change with jumpers on the main board. The Falcon has a 0.56" bright red LED display for high visibility.

Compactly designed for applications requiring minimal rear panel depth, the Falcon fits a standard 1/8 DIN panel cutout (92mm x 45mm) and requires less than 3" behind the panel. A screw terminal connector is a standard feature for easy wiring of the power supply and signal input connections.

DISPLAY

Type

7- segment, red LED

Height

0.56” (14.2mm)

Decimal Point

User-programmable, internally or on the terminal block

Overrange Indication

Most significant digit = “1”; other digits blank

Polarity

Automatic, with “-” indication, ”+” indication implied

 

POWER REQUIREMENTS

AC Voltages

120 or 220VAC, ±10% 50/60Hz

DC Voltages

9-32DCV, ±1%

Power Consumption

F35: 3VA,    F45: 2VA

ISOLATION

250V RMS MAX

 

ACCURACY @25°C

F45 DC Process/Voltage

±0.02% of reading ± 1 count

F35 DC Process/Voltage

±0.1% of reading ± 1 count

F45 DC Current

±0.05% of reading ±1 count

2A ± 5 counts,   5A ± 5 counts

F35 DC Current

±0.1% of reading ± 1 count

2A ± 5 counts,   5A ± 5 counts

F45 AC Voltage/Current

±0.5% of reading ± 35 counts

F35 AC Voltage/Current  *

±1% of reading ± 5 counts (50Hz-100Hz)  * For TRMS (45 Hz to 1KHz)

 

ENVIRONMENTAL

Operating Temperature

0 to 55°C

Storage Temperature

-10 to 60°C

Relative Humidity

0 to 85% non-condensing

Warm-up Time

Less than 15 minutes

 

NOISE REJECTION

NMRR

F35=50dB, 50/60Hz; F45=60dB, 50/60Hz

CMRR

(w/1KΏ  unbalanced @ 60Hz) 90dB min.

 

A TO D CONVERSION

Technique

Dual slope integration

Rate

F35=3 samples per second, nominal;

F45=2.5 samples per second, nominal

 

MECHANICAL

Bezel

3.78” x 1.89” x .51”

Depth

2.94”

Panel Cutout

3.62” X 1.77”

Case Material

94V-1, UL rated Noryl®

Weight

9.0oz (255.1g)

 

Temperature Coefficient

F35 AC/TRMS (Voltage/Current)

(±0.1% of input ± 0.5 count)/°C

F35 DC (Voltage/Current/Process)

(±0.01% of input ± 0.05 count)/°C

F45 AC (Voltage/Current)

(±0.05% of input ± 0.5 count)/°C

F45 DC Current

(±0.01% of input ± 0.1 count)/°C

F45 DC (Voltage/Process)

(±0.05% of input  ± 0.1 count)/°C