We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
Simpson's Model 505 High Voltage Insulation Tester is capable of measuring insulation resistances from 10 kilohms to 1 teraohm with eight selectable test voltages up to 5000 V. As a safety feature, the insulation tester acts as an AC/DC voltmeter to measure the absence of voltage in networks up to 2000 V.
For added safety, the cables are permanently attached, preventing possible injury that could occur by the accidental removal of the cables. The Model 505 features automatic discharging capability of capacitive units under test and a lock-in test switch, for hands free operation. An optional guard terminal is available to minimize surface leakage errors. There are two LEDs to indicate the selected measuring range, and one LED signifying valid measurements and battery charge status.
REFERENCE CONDITIONS | |
Ambient Temperature | 73°F (23°C) ± 4°F (2°C) |
Relative Humidity | 45 to 55% |
Measurement Magnitude Frequency | 60Hz (voltage measurements) |
Line Voltage Waveform | Sine, deviation between effective and rectified value ≈ 1% |
Battery Voltage | 9V ± 1% |
Operating Position | Horizontal |
| |
ELECTROMAGNETIC COMPATIBILITY EMC | |
Interference Emission | EN 50081-1: 1992 |
Interference Immunity | EN 50082-1: 1992 |
| |
ELECTRICAL SAFETY | |
Designed to IEC 1010-1 Protection Class | II |
Test Voltage | ≈ 8.5Kv |
Overvoltage Classification | II |
Pollution Degree | 2 |
Protection | IP 52 |
| |
AMBIENT CONDITIONS | |
Operating Temp. Range | 32°F (0°C) to 104°F (40°C) |
Storage Temp. Range | -4°F (-20°C) to 140°F (60°C) (without batteries) |
Relative Humidity | Max. 75%, condensation must be avoided |
Batteries | 6 ea. 1.5V "D" size batteries |
Working Range | 6 to 10V |
Battery Service Life | 100 hours for no-load and intermittent operation, 7500 measurements for test voltage of 1000V with measure resistance of 1MΏ, 15,000 measurements for test voltage of 500V with measure resistance of 500KΏ, measurement of 5 sec. - pause 25 sec. |
| |
MECHANICAL DESIGN | |
Dimensions | W 11.41” (290mm) x D 9.8” (250mm) x H 5.5” (140mm) |
Weight | 7.5 lbs. (1.6kg) (with batteries) |
Insuation Resistance:
Nominal/Open-Circuit Voltage | Measuring Range | Nominal Current | Short Circuit Current | Intrinsic Error |
100V | 100KOhms to 100MOhms | 1 mA | 1.3 mA | ±2.5% |
100V/1500V | 10KOhms to 1 TOhms | 0.7 mA | 1.3 mA | ±5% |