We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
DC Voltage | ||
Ranges | Accuracy | Sensitivity |
250mV, 1V, 2.5V, 10V, 50V, 250V, 500V, 1000V | 2% of full scale | 20KΏ per volt |
AC Voltage | ||
Ranges | Accuracy | Sensitivity |
2.5V, 10V, 50V, 250V, 500V, 1000V | 3% of full scale | 5KΏ per volt |
Decibel | |
Ranges | -20 to +50dB |
Reference | 0dB = 1mW into 600Ώ |
DC Current | ||
Ranges | Accuracy | Voltage Drop: (Nominal) |
50µA, 1mA, 10mA, 100mA, 250mA, 500mA | 2% of full scale | 350mV Maximum |
Resistance | ||
Ranges | Accuracy | Maxium Indication |
Rx1 |
3° of arc | 0 - 3KΏ |
Rx10 | 0 - 30KΏ | |
Rx100 | 0 - 300KΏ | |
Rx1K | 0 - 3MΏ | |
Rx10K | 0 - 30MΏ |
Batteries | 1.5V AA, 22.5V (Neda No.13F, Eveready 505) |
Operating Temperature Range | 75°F for rated accuracy; less than 4% additional error over the range of +25°F to +130°F |
Size | 4-9/16" x 3-5/16" x 1-3/4" (11.59 x 8.41 x 4.45 cm) |
Weight | Approximately 12 ounces (.34 Kg) |
Construction | Combination high impact plastic and phenolic case |
Circuit To Ground Voltage | 1000V AC/DC Max |