Sensor technology | ||||||
Measuring range | ||||||
Gauge pressure | bar | 0 ... 0.1 (1) | 0 ... 0.25 (2) | 0 ... 0.4 (2) | 0 ... 0.6 (2) | 0 ... 1 |
0 ... 1.6 | 0 ... 2.5 | 0 ... 4 | 0 ... 6 | 0 ... 10 | ||
0 ... 16 | 0 ... 25 | 0 ... 40 | 0 ... 60 | 0 ... 100 | ||
0 ... 160 | 0 ... 200 | 0 ... 250 | 0 ... 400 | 0 ... 600 | ||
0 ... 700 (3) | 0 ... 1,000 (3) | 0 ... 1,600 (4) | 0 ... 2,500 (4) | 0 ... 4,000 (4) | ||
0 ... 6,000 (4) | 0 ... 7,000 (4) | 0 ... 8,000 (4) | 0 ... 10,000 (4) | |||
psi | 0 ... 1.5 (1) | 0 ... 5 (2) | 0 ... 10 (2) | 0 ... 15 | 0 ... 20 | |
0 ... 30 | 0 ... 50 | 0 ... 60 | 0 ... 100 | 0 ... 150 | ||
0 ... 160 | 0 ... 200 | 0 ... 300 | 0 ... 500 | 0 ... 700 | ||
0 ... 1,000 | 0 ... 1,500 | 0 ... 2,000 | 0 ... 3,000 | 0 ... 5,000 | ||
0 ... 6,000 | 0 ... 8,000 | 0 ... 10,000 (3) | 0 ... 15,000 (3) | 0 ... 20,000 (4) | ||
0 ... 30,000 (4) | 0 ... 50,000 (4) | 0 ... 100,000 (4) | 0 ... 150,000 (4) | |||
Absolute pressure | bar | 0 ... 0.25 (2) | 0 ... 0.4 (2) | 0 ... 0.6 (2) | 0 ... 1 | 0 ... 1.6 |
0 ... 2.5 | 0 ... 4 | 0 ... 6 | 0 ... 7 | 0 ... 10 | ||
0 ... 16 | 0 ... 20 | 0 ... 25 | 0 ... 40 | |||
psi | 0 ... 3.5 (2) | 0 ... 5 (2) | 0 ... 10 (2) | 0 ... 15 | 0 ... 20 | |
0 ... 30 | 0 ... 50 | 0 ... 60 | 0 ... 100 | 0 ... 150 | ||
0 ... 200 | 0 ... 300 | 0 ... 500 | ||||
Vacuum and +/- measuring ranges | bar | -0.25 ... +0.25 (2) | -0.4 ... +0.4 (2) | -0.6 ... +0.6 | -1 ... 0 | -1 ... +0.6 |
-1 ... 1.5 | -1 ... 2.5 | -1 ... 3 | -1 ... 5 | -1 ... 7 | ||
-1 ... 9 | -1 ... 10 | -1 ... 15 | -1 ... 24 | -1 ... 25 | ||
-1 ... 39 | -1 ... 40 | |||||
psi | -14.5 ... 0 | -14.5 ... +15 | -14.5 ... 40 | -14.5 ... 70 | -14.5 ... 100 | |
-14.5 ... 130 | -14.5 ... 300 | -3 ... +3 (2) | -5 ... +5 (2) | -8 ... +8 | ||
-3 ... 0 (2) | -5 ... 0 (2) | -8 ... 0 (2) | ||||
Overpressure limit | ||||||
Sensor | 3 times; ≤ 25 bar (≤ 300 psi) 2 times; > 25 ... ≤ 600 bar (> 300 ... ≤ 5,000 psi) 1.7 times; > 600 bar (> 5,000 psi) | |||||
Display | > 110 % FS or -10 % FS | |||||
Accuracy (5) | 0.1 % FS 0.05 % FS (optional) (6) |
(1) Expanded accuracy of 0.2 % FS
(2) Expanded accuracy of 0.15 % FS
(3) Not possible as flush version
(4) Expanded accuracy of 0.5 % FS, at reference conditions 23 °C ±3 °C
(4) It is defined by the total measurement uncertainty, which is expressed with the coverage factor (k = 2) and includes the following factors: the intrinsic performance of the instrument, the measurement uncertainty of the reference instrument, long-term stability, influence of ambient conditions, drift and temperature effects over the compensated range during a periodic
zero point adjustment.
(5) At a measuring rate of ≤ 3 measured values per second
Sensor technology | |
Compensated temperature range | -10 … +50 °C (14 ... 122 °F) |
Type of pressure | Gauge pressure, absolute pressure (up to 20 bar abs. (290 psi abs.)) and vacuum measuring ranges |
Process connection | |
Standard ≤ 1,000 bar (≤ 15,000 psi) | G ½ B, G ¼ B, ½ NPT, ¼ NPT, G 1 B flush, G ½ B flush |
High-pressure version > 1,000 bar (> 15,000 psi) | â– M16 x 1.5 female with sealing cone â– M20 x 1.5 female with sealing cone â– 9/16 - 18 UNF female F 250-C |
Pressure medium | All liquids and gases which are compatible with 316 stainless steel |
Base instrument | |
Display | |
Display | 5 ½ digit 7-segment display including a large matrix area for auxiliary information Bar graph, 0 ... 100 % Selectable backlighting |
Rotatable case | The case is rotatable by 330° |
Resolution | 4 ... 5 ½ digit; adjustable; dependent on the selected pressure unit |
Pressure units | Standard: psi, bar Selectable to: mbar, kg/cm², Pa, hPa, kPa, Mpa, mmH2O, mH2O, inH2O, inH2O (4 °C), inH2O (20 °C), inH2O (60 °F), ftH2O, mmHg, cmHg, inHg, inHg (0 °C), inHg (60 °F), kp/cm2, lbf/ft2, kN/m2, atm, Torr, micron as well as user-defined units (7) |
Functions | |
Measuring rate | max. 50/s |
Menu languages | Standard: English Selectable: German, Italian, French, Spanish, Russian and Polish |
Memory | Standard: Min./Max. Optional: integrated data logger |
Menu functions | Min./Max. alarm (visual), power-off function, measuring rate, mean value filter, pressure rate, mean value (via adjustable interval), level indicator, Tare offset, display damping |
Mean value interval | 1 ... 300 seconds, adjustable |
Data logger (8) | Cyclic logger: Automatic recording of up to 1,000,000 values; Cycle time: selectable from 1 ... 3,600 s. in steps of 1 second or by measuring rate in the following steps: 1/s, 3/s, 10/s and 50/s |
Material | |
Wetted parts | ≤ 1.000 bar: Stainless steel 316 > 1.000 bar: Stainless steel 1.4534 |
Case | Aluminium die-casting, nickel-plated |
Voltage supply | |
Power supply | 3 x 1.5 V AA alkaline batteries (9) |
Maximum voltage | DC 4.95 V (spark ignition) |
Battery life | typical 2,000 ... 2,500 h (without backlighting and WIKA-Wireless not active) |
Battery status indication | Symbol display, with 4 bars displaying the battery status in segments of 25 % |
Permissible ambient conditions | |
Operating temperature | -10 ... +50 °C (14 ... 122 °F) |
Medium temperature | -10 ... +50 °C (14 ... 122 °F) (lower temperature limit above the freezing point of the medium) |
Storage temperature | -20 ... +70 °C (-4 ... +158 °F) |
Relative humidity | < 95 % r. h. (non-condensing) |
(7) The user-defined units can only be set via the WIKA-Cal software. The CPG1500 must feature WIKA-Wireless.
(8) To use the logger function, WIKA-Cal software is needed.
The logger data can be downloaded with the WIKA-Cal demo version as a CSV file. The live logger, an accurate data analysis or a direct certificate creation can be used with the logger template WIKA-Cal.
(9) For hazardous areas, only the following types are allowed:
â– Duracell, Simply by Duracell MN1500
â– Duracell, Duralock Plus Power MN1500
â– Varta, RAYOVAC Maximum Plus 4006
Base instrument | |
Communication (optional) | |
Interface | WIKA-Wireless (10) |
Case | |
Dimensions | approx. 100 x 150 x 59 mm (3.9 x 5.9 x 2.3 in) |
Ingress protection | IP65 |
Weight | Standard: incl. batteries approx. 680 g ( 1.5 lbs) with protective rubber cap: approx. 820 g (1.81 lbs) |
WIKA-Wireless (10) | |
Frequency range | 2,400 ... 2,500 MHz |
HF output power | max. 2 dBm (+ 2 dBi) |
Number of channels | 40 |
Channel spacing | 1 or 2 MHz |
Bandwidth | 1 or 2 MHz |
Output power | 4 dBm / 10 mW Maximum output power under fault conditions for Ex ia: 490 mW |
(10) Requires a PC with Bluetooth® 2.1 interface
- Oil and gas industry
- Maintenance and service facilities
- Calibration service companies and service industry
- Simple calibrations directly on site