Wika Mensor CPG1500 Precision Digital Pressure Gauge

SKU
CPG1500ST
Manufacturer:
Wika Mensor
Wika Mensor

Key Features:

  • Measuring ranges up to 0 ... 1,000 bar (0 ... 15,000 psi), vacuum and absolute pressure ranges also available
  • Accuracy: up to 0.05 % (incl. calibration certificate)
  • Intrinsically safe version
  • Logger function with up to 50 measured values per second
  • Communication with WIKA-CAL software over WIKA-Wireless
Product Options:
Call For Price

Secured and trusted checkout with

Wika Mensor is introducing their CPG1500 Digital Pressure Gauge with an accuracy of 0.1 % of span (optional 0.05 % of span) and temperature-compensated in the range of -10 … +50 °C (14 ... 122 °F). Users can view readings in one of 26 pressure and 5 level units or in their own specified units. More still, the gauge features a new effortless menu navigation, clear display with integral bar graph and MIN/MAX function.
Sensor technology
Measuring range
Gauge pressurebar0 ... 0.1 (1)0 ... 0.25 (2)0 ... 0.4 (2)0 ... 0.6 (2)0 ... 1
0 ... 1.60 ... 2.50 ... 40 ... 60 ... 10
0 ... 160 ... 250 ... 400 ... 600 ... 100
0 ... 1600 ... 2000 ... 2500 ... 4000 ... 600
0 ... 700 (3)0 ... 1,000 (3)0 ... 1,600 (4)0 ... 2,500 (4)0 ... 4,000 (4)
0 ... 6,000 (4)0 ... 7,000 (4)0 ... 8,000 (4)0 ... 10,000 (4) 
psi0 ... 1.5 (1)0 ... 5 (2)0 ... 10 (2)0 ... 150 ... 20
0 ... 300 ... 500 ... 600 ... 1000 ... 150
0 ... 1600 ... 2000 ... 3000 ... 5000 ... 700
0 ... 1,0000 ... 1,5000 ... 2,0000 ... 3,0000 ... 5,000
0 ... 6,0000 ... 8,0000 ... 10,000 (3)0 ... 15,000 (3)0 ... 20,000 (4)
0 ... 30,000 (4)0 ... 50,000 (4)0 ... 100,000 (4)0 ... 150,000 (4) 
Absolute pressurebar0 ... 0.25 (2)0 ... 0.4 (2)0 ... 0.6 (2)0 ... 10 ... 1.6
0 ... 2.50 ... 40 ... 60 ... 70 ... 10
0 ... 160 ... 200 ... 250 ... 40 
psi0 ... 3.5 (2)0 ... 5 (2)0 ... 10 (2)0 ... 150 ... 20
0 ... 300 ... 500 ... 600 ... 1000 ... 150
0 ... 2000 ... 3000 ... 500
Vacuum and +/- measuring rangesbar-0.25 ... +0.25 (2)-0.4 ... +0.4 (2)-0.6 ... +0.6-1 ... 0-1 ... +0.6
-1 ... 1.5-1 ... 2.5-1 ... 3-1 ... 5-1 ... 7
-1 ... 9-1 ... 10-1 ... 15-1 ... 24-1 ... 25
-1 ... 39-1 ... 40 
psi-14.5 ... 0-14.5 ... +15-14.5 ... 40-14.5 ... 70-14.5 ... 100
-14.5 ... 130-14.5 ... 300-3 ... +3 (2)-5 ... +5 (2)-8 ... +8
-3 ... 0 (2)-5 ... 0 (2)-8 ... 0 (2) 
Overpressure limit
Sensor3 times; ≤ 25 bar (≤ 300 psi)
2 times; > 25 ... ≤ 600 bar (> 300 ... ≤ 5,000 psi)
1.7 times; > 600 bar (> 5,000 psi)
Display> 110 % FS or -10 % FS
Accuracy (5)0.1 % FS
0.05 % FS (optional) (6)

(1) Expanded accuracy of 0.2 % FS
(2) Expanded accuracy of 0.15 % FS
(3) Not possible as flush version
(4) Expanded accuracy of 0.5 % FS, at reference conditions 23 °C ±3 °C
(4) It is defined by the total measurement uncertainty, which is expressed with the coverage factor (k = 2) and includes the following factors: the intrinsic performance of the instrument, the measurement uncertainty of the reference instrument, long-term stability, influence of ambient conditions, drift and temperature effects over the compensated range during a periodic
zero point adjustment.
(5) At a measuring rate of ≤ 3 measured values per second

 

 

Sensor technology

Compensated temperature range

-10 … +50 °C (14 ... 122 °F)

Type of pressure

Gauge pressure, absolute pressure (up to 20 bar abs. (290 psi abs.)) and vacuum measuring ranges

 

Process connection

Standard

≤ 1,000 bar (≤ 15,000 psi)

G ½ B, G ¼ B, ½ NPT, ¼ NPT, G 1 B flush, G ½ B flush

High-pressure version

> 1,000 bar (> 15,000 psi)

â–   M16 x 1.5 female with sealing cone

â–   M20 x 1.5 female with sealing cone

â–   9/16 - 18 UNF female F 250-C

Pressure medium

All liquids and gases which are compatible with 316 stainless steel

 

 

Base instrument
Display
Display5 ½ digit 7-segment display including a large matrix area for auxiliary information
Bar graph, 0 ... 100 %
Selectable backlighting
Rotatable caseThe case is rotatable by 330°
Resolution4 ... 5 ½ digit; adjustable; dependent on the selected pressure unit
Pressure unitsStandard: psi, bar
Selectable to: mbar, kg/cm², Pa, hPa, kPa, Mpa, mmH2O, mH2O, inH2O, inH2O (4 °C), inH2O (20 °C),
inH2O (60 °F), ftH2O, mmHg, cmHg, inHg, inHg (0 °C), inHg (60 °F), kp/cm2, lbf/ft2, kN/m2, atm, Torr,
micron as well as user-defined units (7)
Functions

Measuring rate

max. 50/s

Menu languages

Standard: English

Selectable: German, Italian, French, Spanish, Russian and Polish

Memory

Standard: Min./Max.

Optional: integrated data logger

Menu functions

Min./Max. alarm (visual), power-off function, measuring rate, mean value filter, pressure rate, mean value (via adjustable interval), level indicator, Tare offset, display damping

Mean value interval

1 ... 300 seconds, adjustable

Data logger (8)

Cyclic logger: Automatic recording of up to 1,000,000 values;

Cycle time: selectable from 1 ... 3,600 s. in steps of 1 second or by measuring rate in the following steps: 1/s, 3/s, 10/s and 50/s

Material
Wetted parts≤ 1.000 bar: Stainless steel 316
> 1.000 bar: Stainless steel 1.4534
CaseAluminium die-casting, nickel-plated
Voltage supply
Power supply3 x 1.5 V AA alkaline batteries (9)
Maximum voltageDC 4.95 V (spark ignition)
Battery lifetypical 2,000 ... 2,500 h (without backlighting and WIKA-Wireless not active)
Battery status indicationSymbol display, with 4 bars displaying the battery status in segments of 25 %
Permissible ambient conditions
Operating temperature-10 ... +50 °C (14 ... 122 °F)
Medium temperature-10 ... +50 °C (14 ... 122 °F) (lower temperature limit above the freezing point of the medium)
Storage temperature-20 ... +70 °C (-4 ... +158 °F)
Relative humidity< 95 % r. h. (non-condensing)

(7) The user-defined units can only be set via the WIKA-Cal software. The CPG1500 must feature WIKA-Wireless.
(8) To use the logger function, WIKA-Cal software is needed.
The logger data can be downloaded with the WIKA-Cal demo version as a CSV file. The live logger, an accurate data analysis or a direct certificate creation can be used with the logger template WIKA-Cal.
(9) For hazardous areas, only the following types are allowed:
â–  Duracell, Simply by Duracell MN1500
â–  Duracell, Duralock Plus Power MN1500
â–  Varta, RAYOVAC Maximum Plus 4006

 

Base instrument
Communication (optional)
InterfaceWIKA-Wireless (10)
Case
Dimensionsapprox. 100 x 150 x 59 mm (3.9 x 5.9 x 2.3 in)
Ingress protectionIP65
WeightStandard: incl. batteries approx. 680 g ( 1.5 lbs)
with protective rubber cap: approx. 820 g (1.81 lbs)

 

WIKA-Wireless (10)
Frequency range2,400 ... 2,500 MHz
HF output powermax. 2 dBm (+ 2 dBi)
Number of channels40
Channel spacing1 or 2 MHz
Bandwidth1 or 2 MHz
Output power4 dBm / 10 mW
Maximum output power under fault conditions for Ex ia: 490 mW

(10) Requires a PC with Bluetooth® 2.1 interface

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
  • Oil and gas industry
  • Maintenance and service facilities
  • Calibration service companies and service industry
  • Simple calibrations directly on site