The GPT-9612 hipot tester is an instrument for AC voltage safety withstand testing (hipot) and insulation resistance testing. Perform AC hipot tests to 5000 volts AC. The GPT-9612 also performs insulation resistance testing to 2000 M-Ohms. The bright blue Dot Matrix LCD gives the test engineer all they need at their finger tips to meet IEC, EN, UL, ETL, CSA, GB, JIS and other safety standards. Custom calibration certificates are available to help the end user prove traceability and accuracy to their standards inspection body or organization.
AC WITHSTANDING (All Models) | |||
Output-Voltage Range | 0.10kV~ 5.00kV ac | ||
Output-Voltage Resolution | 10V | ||
Output-Voltage Accuracy | ± (1.5% of setting + 2 counts) with no load | ||
Maximum Rated Load | 100 VA (5kV/20mA) | ||
Maximum Rated Current | 20mA (0.5kV < V ≦ 5kV) 5mA (0.1kV ≦ V≦ 0.5kV) | ||
Output-Voltage Waveform | Sine wave | ||
Output-Voltage Frequency | 50 Hz / 60 Hz selectable | ||
Voltage regulation | ± (1.5% + 2 counts) [full load → no load] | ||
Voltmeter Accuracy | ± (1.5% of reading + 2 counts) | ||
Current Measurement Range | 0.01mA~20.0mA | ||
Current Best Resolution | 0.01mA / 0.1mA | ||
Current Measurement Accuracy | ±(2.0% of reading + 5 counts) when HISET < 1.00mA ±(2.0% of reading + 3 counts) when HISET ≧ 1.00mA | ||
Current Judgment Accuracy | ±(3.0% of setting + 5 counts) when HISET < 1.00mA ±(3.0% of setting + 3 counts) when HISET ≧ 1.00mA | ||
Window Comparator Method | Yes | ||
ARC Detect | Yes | ||
RAMP (Ramp-Up Time) | 0.1s fixed | ||
TIMER (Test Time) | OFF, 1s~180s | ||
GND | ON | ||
DC WITHSTANDING (GPT-9602 & GPT-9603) | |||
Output-Voltage Range | 0.10kV~ 6.00kV dc | ||
Output-Voltage Resolution | 10V | ||
Output-Voltage Accuracy | ± (1.5% of setting + 2 counts) with no load | ||
Maximum Rated Load | 25W (5kV/5mA) | ||
Maximum Rated Current | 6mA (0.5kV < V ≦ 6kV) 2mA (0.1kV ≦ V≦ 0.5kV) | ||
Voltage regulation | ± (1.5% + 2 counts) [full load → no load] | ||
Voltmeter Accuracy | ± (1.5% of reading + 2 counts) | ||
Current Measurement Range | 0.01mA~6.00mA | ||
Current Best Resolution | 0.01mA | ||
Current Measurement Accuracy | ±(2.0% of reading + 5 counts) when HISET < 1.00mA ±(2.0% of reading + 3 counts) when HISET ≧ 1.00mA | ||
Current Judgment Accuracy | ±(3.0% of setting + 5 counts) when HISET < 1.00mA ±(3.0% of setting + 3 counts) when HISET ≧ 1.00mA | ||
Window Comparator Method | Yes | ||
ARC Detect | Yes | ||
RAMP (Ramp-Up Time) | 0.1s fixed | ||
TIMER (Test Time) | OFF, 1s~180s | ||
GND | ON | ||
INSULATION RESISITANCE (GPT-9603 & GPT-9612) | |||
Output-Voltage | 50V, 100V, 250V, 500V, 1000V dc | ||
Output-Voltage Accuracy | ± (3.0% of setting + 1 count) [no load] | ||
Resistance Measurement Range | 1MW~ 2000MW | ||
| Test voltage | Measurable Range | Accuracy |
| 50V/100V/250V | 1~ 50MW 51~ 2000MW | ±(5% of reading + 2MW) ±(10% of reading + 2MW) |
| 500V/1000V | 1~ 500MW 501~ 2000MW | ±(5% of reading + 2MW) ±(10% of reading + 2MW) |
Window Comparator Method | Yes | ||
Output Impedance | 600kW | ||
RAMP (Ramp-Up Time) | 0.1s fixed | ||
TIMER (Test Time) | OFF, 1s~180s | ||
GND | OFF (fixed) | ||
TEST MODE* | |||
SINGLE | ACW, DCW, IR | ||
AUTO | AC-IR, IR-AC, DC-IR, IR-DC | ||
INTERFACE | |||
Remote Terminal (Front) | Standard | ||
SIGNAL IO | Standard | ||
General | |||
DISPLY | 240 x 48 Ice Blue dot matrix LCD | ||
POWER SOURCE | AC 100V-120V/220V-240V ±10%, 50/60Hz | ||
POWER COMSUMPTION | 400VA max. | ||
DIMENSIONS & WEIGHT | 330(W) x 148(H) x 385(D) mm approx.9kg(Max) |
* The available “Test Mode” depends on selected model