Fluke 107 Palm-sized CAT III Digital Multimeter

SKU
FLUKE-107 ESP
Manufacturer:
Fluke
Fluke

Key Features:

  • Enabled with current and voltage measurement functions, in a compact size
  • Measures resistance & continuity to check for broken wires
  • Data hold & backlit display to keep you working safe and fast
  • AC and DC voltage measurement
  • AC and DC current measurement
  • Resistance measurement
  • Capacitance measurement
  • Diode measurement
  • Frequency and duty cycle test and other functions to meet basic electrical maintenance, electrical measurement, and electronic measurement applications
  • Comfortable grip, only weighs 200g and easy to carry
  • Rugged enclosure and 1-meter drop test
  • Full-parameter automatic range test, which is convenient and quick to test; at the same time, it reduces the number of rotations of the wave plate and prolongs the life of the instrument.
  • 6000-word large screen LCD backlight display
  • Battery powered, automatic power save mode
  • Data retention feature makes it easier to read measurement results
  • Comes with SmartStrap™ intelligent magnetic multi-purpose lanyard
  • Compliant with IEC61010-1 CATIII 600V overvoltage protection safety standard
  • Fluke 107 Comes with Fluke TL75 Hard Point™ Test Lead Set
    • One pair (red, black) of comfort grip probes
    • 48 inches (1.22 meter) PVC insulated test leads with right-angle shrouded banana plugs
    • Recommended for general purpose measurements
    • CAT II 1000 V, 10 A rating
    • CAT IV 600 V, CAT III 1000 V only with protective cap
  • one-year warranty
Product Options:
$155.99

Secured and trusted checkout with

The Fluke 107 is a compact, simple to operate digital multimeter constructed to fit the way you work. It is the perfect first-pass troubleshooting tool: small enough to fit in a shirt pocket or work bag, durable enough to withstand daily use, and extremely easy to use. All without compromising safety. For everyday applications, where True-RMS accuracy isn’t needed, the Fluke 107 delivers reliable measurements continuously.

Accuracy is available for one year after calibration, operating from 18 °C to 28 °C and relative humidity from 0% to 75%. The format of the accuracy specification is: ± ([% of reading] + [least significant digit])

Precision specifications
AC voltage
(40 Hz to 500 Hz) 1)
RangeResolutionAccuracy
6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
1.0 % + 3
DC voltage6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
0.5 % + 3
Exchange millivolts600.0 mV0.1 mV3.0 % + 3
Diode test 2)2.000 V0.001 V10 %
Resistance
(ohm)
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5% + 3
Capacitor 3)50.00 nF
500.0 nF
5.000 μF
50.00 μF
500.0 μF
1000 μF
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5
Frequency 4) Hz
(10 Hz – 100 kHz)
50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
0.1 % + 3
Duty cycle 4)1 % to 99 %0.10 %1 % typical case 5)
AC current
(40 Hz - 200 Hz)
4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
DC4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
1) All AC current, frequency, and duty cycle are specified from 1% to 100% of the range. Input values below 1% of range are not specified.
2) Typically, the open circuit test voltage is 2.0 V and the short circuit current is < 0.6 mA.
3) The parameters do not include errors due to test lead capacitance and capacitor substrate (up to 1.5 nF in the 50 nF range).
4) All AC current, frequency, and duty cycle are specified from 1% to 100% of the range. Input values below 1% of range are not specified.
5) Typically, the frequency is 50 Hz or 60 Hz and the duty cycle is 10% to 90%.
FeaturesOverload protectionInput impedance (nominal value)Common mode rejection ratioNormal mode rejection ratio
AC voltage600 V 1)>10 MΩ <100 pF 2)>60 dB at 50 Hz or 60 Hz at DC current
Exchange millivolts600 mV>1M, <100 pF>80 dB at 50 Hz or 60 Hz
DC voltage600 V 1)>10 MΩ <100 pF>100 dB at 50 Hz or 60 Hz at DC current>60 dB at 50 Hz or 60 Hz
1) Up to 6 x 105 V Hz
2) For medium voltage (alternating current), the input impedance is approximately 1 MΩ.
General technical indicators
The highest voltage applied to any terminal and ground600 V
Display (LCD)6000 counts, updated three times per second
Type of batteryTwo AAA batteries (NEDA 24A, IEC LR03)
Battery lifeAt least 200 hours
Temperature
Operating temperature0 °C to 40 °C
Storage temperature-30 °C to 60 °C
Relative humidity
Working humidityNo condensation below 10 °C
≤ 90 % at 10 °C to 30 °C; ≤ 75 % at 30 °C to 40 °C
Working humidity, 40 MΩ range≤ 80 % at 10 °C to 30 °C; ≤ 70 % at 30 °C to 40 °C
Altitude
Working elevation2000 m
Storage altitude12,000 m
Temperature coefficient0.1 X (specified accuracy) / °C (<18 °C or >28 °C)
Current input fuse protection11A, 1000V fast-melting type, must use Fluke designated parts
Volume (height x width x length)142 mm x 69 mm x 28 mm
Weight200 g
Protection levelIEC 60529: IP 40
SafetyIEC 61010-1: 600 V CAT III, pollution degree 2
Electromagnetic environmentIEC 61326-1: Portable
Electromagnetic compatibilityApplicable only in Korea. Class A equipment (industrial broadcasting and communication equipment)1)
1) This product meets the requirements of industrial (Class A) electromagnetic wave equipment, which should be noted by the seller or user. The device is suitable for use in a work environment, not a home environment.
Write Your Own Review