R2160 Thermal Imaging Camera
Imaging and Optical Specifications | |
Field of View (FOV) | 56 x 42° |
Minimum Focus Distance | 0.82' (0.25m) |
Spatial Resolution | (IFOV) 11mrad |
Thermal Sensitivity (NETD) | <0.05°C (50mK) |
Image Capture Frequency | 9Hz |
Focus | Fixed |
Measurement | |
Temperature Range | 14 to 752°F (-10 to 400°C) |
Accuracy | ±3.6°F (2°C) or ±2% of reading |
Resolution | 0.1°F/°C |
Detector Specifications | |
Detector Type | Uncooled microbolometer, Focal plane array (FPA) |
Spectral Range | 8 to 14μm |
IR Resolution | 160 x 120 (19,200 pixels) |
Image Presentation and Measurement Analysis | |
Display | 2.8" color TFT |
Color Palettes | 5 (Iron/Rainbow/Gray/Red-White/White-Blue) |
Center Spot | Yes |
Emissivity | Adjustable (0.01 to 0.99) |
Temperature Alarm Indicators | High/Low (user adjustable) |
Automatic Hot/Cold Detection | Auto hot or cold spot-meter markers |
General Specifications | |
Display Resolution | 320 x 240 pixels |
Image Format | BMP |
LED Flashlight | Yes |
External Memory | Micro SD card |
Auto Shut-Off | Yes (user adjustable 5/10/30 minutes) |
Tripod Mountable | Yes |
Low Battery Indicator | Yes |
Power Supply | 3.7V/5000mAh rechargeable Li-ion battery |
Battery Life | Approximately 6 hours |
Charging System | In camera |
Charge Time | 4 hours |
PC Connectivity | USB Cable (Type-C) |
Software | Yes (download from website) |
Software OS Compatibility | Windows 7/8/10/11 |
Supported Languages | English and French |
Product Certifications | CE, IP65, 6.5' (2m) drop test |
Temperature | Operating: 32 to 122°F (0 to 50°C) Storage: -4 to 140°F (-20 to 60°C) |
Operating/Storage Humidity Range | 10 to 90% |
Maximum Operating Altitude | 6561' (2000m) |
Dimensions | 9.3 x 3 x 3.4" (236 x 76 x 86mm) |
Weight | 1lbs (454g) |
R6250SD Data Logging Heat Stress Meter
Temperature | |
Measuring Ranges | Air: 32 to 122.0°F (0 to 50.0°C) Dew Point: -13.5 to 120.1°F (-25.3 to 48.9°C) Wet Bulb: -6.9 to 122.0°F (-21.6 to 50°C) Black Globe: 32 to 176°F (0 to 80°C) Indoor WBGT: 32 to 138°F (0 to 59°C) Outdoor WBGT: 32 to 132°F (0 to 56°C) |
Accuracy | Air: ±1.5°F (±0.8°C) Black Globe: ±1.1°F (±0.6°C) Indoor WBGT: ±2.7°F (±1.5°C) Outdoor WBGT: ±3.6°F (±2°C) |
Resolution | 0.1°F/°C |
Humidity | |
Measuring Ranges | 5 to 95% RH |
Accuracy | >70% RH: ±(3% rdg + 1% RH) <70% RH: ±3% RH |
Resolution | 0.1% RH |
General Specifications | |
Indoor Formula | 0.7WB + 0.3TG |
Indoor Range | 32 to 138°F (0 to 59°C) |
Indoor Accuracy | ±2.7°F (±1.5°C) |
Outdoor Formula | 0.7WB + 0.3TG + 0.1TA |
Outdoor Range | 32 to 132°F (0 to 56°C) |
Outdoor Accuracy | ±3.6°F (±2°C) |
Response Time | 1 second |
Display | 4-digit dual LCD |
Backlit Display | Yes |
Data Hold | Yes |
Min | Yes |
Max | Yes |
Datalogging Capabilities | Yes |
Real-Time Clock and Date Stamp | Yes |
Selectable Sampling Rate | Yes (1, 2, 5, 10, 30, 60, 120, 300, 600, 1800, 3600 seconds) |
External Memory | Yes, expandable up to 16GB with SD card (optional) |
Auto Shut-off | Yes (after 10 minutes/off) |
Kick Stand | Yes |
Tripod Mountable | Yes |
Low Battery Indicator | Yes |
Power Supply | 6 x AA Batteries or AC Adapter (optional) |
Data Output | Yes (RS-232) |
Product Certifications | CE |
Operating Temperature | 32 to 122°F (0 to 50°C) |
Storage Temperature | 14 to 140°F (-10 to 60°C) |
Operating Humidity Range | 10 to 85% |
Dimensions | Instrument: 7.0 x 2.7 x 1.8" (177 x 68 x 45mm) Black Brass Ball Diameter: 2.9" (75mm) |
Weight | 1.1lb (515g) |
Write Your Own Review
- • Home and building inspection
- • Plant and general maintenance
- • Electrical and mechanical inspection
- • Predictive maintenance
- • HVAC/R and plumbing
- • Equine and veterinary