PIECAL 901 Wireless Diagnostic Calibrator

SKU
PIE 901
Manufacturer:
PIECAL
PIECAL

Key Features:

  • Calibrate Milliamp Instruments
    Source 0.000 to 24.000 mA & -25.00 to 125.00% of 4-20 mA
    Read 0.000 to 24.000 mA & -25.00 to 125.00% of 4-20 mA
    Simulate 2-Wire Transmitter, Power & Read Transmitters
    Accurate to ±(0.01% of Reading + 0.002 mA)
  • Calibrate Voltage Instruments
    Source 0.000 to 24.000 VDC
    Read -60.000 to 60.000 VDC
    Accurate to ± (0.02% of Reading + 0.01% Full Scale)
  • Calibrate pressure instruments with optional pressure modules
    Dual display of milliamp and pressure for calibration of I/P or  P/I transducers and pressure gauges
    Choose from a wide selection of pressure modules along with hand pumps and tubing kits
  • Blue tooth functionality (for use with future PIE wireless pressure modules)
  • Large Color Display with color coded menus for simplified setup
  • Locate Loop Current Leakages
    Automatic indication of Loop Current and Leakage Current. Measure ground current leakage from faulty wiring, flooded conduit and corrosion bridges. Leakage typically appears as a Zero Shift and helps you decide if the transmitter needs calibration or if there is a problem in the loop wiring.
  • Faster Calibrations
    Three output EZ-CHECK switch
    2 speed EZ-DIAL
    Stepping & Ramping
  • Includes Rubber Boot, Deluxe Hands Free Carrying Case, USBC Charger, 4 NiMh Rechargeable Batteries & Test Leads
Product Options:
$1,659.00

Secured and trusted checkout with

The PIECAL 901 is a millamp, voltage and pressure calibrator that finds hidden loop problems. The PIE 901 allows you to check, calibrate and measure all your current, voltage and pressure instruments in a 4 to 20 milliamp DC loop. This calibrator can simultaneously output 24V DC to power any and all devices in a process loop using the internal batteries and internal switching power supply, while measuring the output of a 2 Wire Transmitter and any other loop devices.

Unless otherwise indicated all specifications are rated from a nominal 23°C, 70% RH for 1 year from calibration

General
Operating Temperature Range-20 to 60 °C (-5 to 140 °F)
Storage Temperature Range-30 to 60 °C (-22 to 140 °F)
Temperature effect≤ ± 0.005 %/°C of range for the
temperature ranges -20 to 18°C & 28 to 60°C
Relative Humidity Range10 % ≤RH ≤90 % (0 to 35 °C), Non-condensing
10 % ≤RH≤ 70 % (35 to 60 °C), Non-condensing
Isolation:Voltage: 60 V rms between all mA & voltage functions / Pressure
Common Mode: 50/60 Hz, 100 dB
Normal Mode Rejection50/60 Hz, 50 dB
Noise≤ ± ½ Least Significant Digit ???
Size5.63 x 3.00 x 1.60 inches, 143 x 76 x 41 mm (L x W x H)
Weight12.1 ounces, 0.34 kg (including boot & batteries)
BatteriesFour “AA” Alkaline 1.5V (LR6)
Optional AC Adaptor100 to 240 VAC 50/60 Hz [Part # 020-0104]
Optional NiMh Rechargeable
battery set
Four NiMh batteries [Part # 020-0105]
Low BatteryLow battery indication with nominal 1 hour of operation left
Protection against misconnectionOver-voltage protection to 60 vrms (rated for 30 seconds)
DisplayHigh contrast color graphic liquid crystal display with LED backlighting for use in low lit areas.
Switch to DARK MODE for use in bight sunlight.

 

Read mA
Ranges and Resolution0.000 to 24.000 mA or -25.00 to 125.00% of 4-20 mA
Accuracy≤ ± (0.01 % of Reading +0.002 mA)
Voltage burden≤ 3V at 20 mA
Overload/Current limit protection25 mA nominal
Battery lifeAlkaline ≥ 10 hours
NiMH ≥ 15 hours

 

Battery Charging
Charge Time<11.5 hours

 

Source mA/Power & Measure Two Wire Transmitters
Ranges and Resolution0.000 to 24.000 mA or -25.00 to 125.00% of 4-20 mA
Accuracy≤ ± (0.01 % of Reading +0.002 mA)
Loop compliance voltage≥ 24 DCV @ 20.00mA
Loop drive capability - Leak
Detection Off
Loop drive capability - Leak
Detection On
1200 Ω at 20 mA
950 Ω with Hart Resistor enabled
1000 Ω at 20 mA
750 Ω with Hart Resistor enabled
Battery lifeAlkaline ≥ 7.5 Hours nominal
NiMH ≥ 10 Hours nominal

 

mA 2-Wire Transmitter Simulation
AccuracySame as Source/Power & Measure
Voltage burden≤ 3V at 20 mA
Overload/Current limit protection25 mA nominal
Loop voltage limits3 to 60 VDC (fuse-less protected from reverse polarity connections)

 

DC Voltage Read
Range and Resolution-60.000 to 60.000 VDC
Accuracy≤ ± (0.02 % of Reading +0.01% Full Scale)
Input resistance≥ 2 MΩ
Battery lifeAlkaline ≥ 9 hours
NiMH ≥ 15 hours

 

Source DC Voltage
Range and Resolution0.000 to 24.000 VDC
Accuracy≤ ± (0.02 % of Reading +0.01% Full Scale)
Source Current; Sink Current≥ 20 mA; > 16 mA
Output Impedance< 0.3 Ohm
Short Circuit DurationInfinite