PIECAL 525Plus Diagnostic Temperature and mA Loop Calibrator

SKU
PIE-525Plus
Manufacturer:
PIECAL
PIECAL

Key Features:

  • Three Calibrators in One!
  • Troubleshoot loop problems
  • Calibrate directly in temperature (°C & °F)
  • Measure & Source 12 RTD sensors
  • Calibrate14  thermocouple types 
  • Lab accuracy and stability
  • Measures thermocouples resistance to detect trouble before costly failures
  • Checkout all your 4 to 20 mA loops & instruments
  • Fast calibration with automatic output stepping
  • Loop power supply with 250 Ohm Hart resistor
  • Meets AMS 2750 Aerospace test instrument requirement
Product Options:
$3,099.00

Secured and trusted checkout with

The PIECAL 525Plus combines the functionality of aThermocouple Calibrator and an RTD Calibrator plus a Milliamp Loop Calibrator into one compact instrument.. The 525Plus also has advanced diagnostics including the unique ability to check the health of a thermocouple sensor by simultaneously displaying the resistance of the sensor and wiring while measuring the temperature being sensed by the thermocouple element. This calibrator can power up a temperature transmitter while simulating the thermocouple or RTD sensor input. Plus it has PIE’s patented Leak Detection to troubleshoot loop wiring problems.

 

The PIECAL 525+ is a great tool for trouble shooting loop problems with ground faults or leakage currents. Source of measure 14common thermocouple types or test 2, 3 or 4 wire RTD sensors (12 types). Resolution is up to 0.01 Degrees. The 525plus can power most any transmitters and works with pulse current type transmitters. The system accuracy allows the testing of field devices used in AMS 2750 surveys.

General
Operating Temperature Range-25 to 60 °C (-10 to 140 °F)
Storage Temp. Range-30 to 60 °C (-22 to 140 °F)
Relative Humidity Range10 % ≤RH ≤90 % (0 to 35 °C), Non-condensing
10 % ≤RH≤ 70 % (35 to 60 °C), Non-condensing
Temperature Drift± 0.01% of span outside of 23°C ±10 °C (73°C ±18 °F)
Size5.63 x 3.00 x 1.60 in, 143 x 76 x 41 mm (L x W x H)
Weight12.1 ounces, 0.34 kg (including boot & batteries)
BatteriesFour “AA” Alkaline 1.5V (LR6)
Battery Life (Typical)25 Hours Thermocouple or RTD, 8 Hours milliamp
Isolation: Voltage60V rms between all milliamp functions/Read V DC and Source V DC/Thermocouple/Ohms/RTD
Normal Mode Rejection50/60 Hz, 50 dB
Common Mode Rejection50/60 Hz, 120 dB
Optional NiMh Rechargeable battery kitCharger, four NiMh batteries [Part # 020-0103]
Low BatteryLow battery indication with nominal 1 hour of operation left
Protection against misconnectionOver-voltage protection to 60 V dc (rated for 30 seconds)
DisplayHigh contrast graphic liquid crystal display. LED backlighting for use in low lit areas.

 

Read mA
Ranges and Resolution0.000 to 24.000 mA or -25.00 to 125.00% of 4-20 mA
Accuracy≤ ± (0.02 % of Reading + 0.003 mA)
Voltage burden≤ 2V at 24 mA
Overload/Current limit protection25 mA nominal

 

Source mA / Power & Measure Two Wire Transmitters & PWRM LEAK
Ranges and Resolution0.000 to 24.000 mA or -25.00 to 125.00% of 4-20 mA
Accuracy≤ ± (0.02 % of Reading + 0.003 mA)
Loop compliance voltage≥ 24 DCV @ 20.00mA
Loop drive capability1200 Ω at 20 mA
950 Ω with Hart Resistor or leak detection running

 

mA 2-Wire Transmitter Simulation
AccuracySame as Source/Power & Measure
Voltage burden≤ 2V at 20 mA
Overload/Current limit protection24 mA nominal
Loop voltage limits2 to 60 VDC (fuse-less protected from reverse polarity connections)

 

Source Thermocouple
Accuracy±(0.008% of Reading + 0.006 mV)
Cold Junction Compensation± 0.09°F (±0.05 °C) - Thermistor traceable to NIST for 11 years
Millivolt Range-13.000 to 80.000 mV
Output Impedance< 0.3 Ohms
Source Current> 20 mA (drives 80 mV into 10 Ohms)
Noise≤ 4 microvolts p-p for frequencies of 10 Hz or below

 

Read Thermocouple
Accuracy±(0.008% of Reading + 0.006 mV)
Cold Junction Compensation± 0.09°F (±0.05 °C) - Thermistor traceable to NIST for 11 years
Millivolt Range-13.000 to 80.000 mV
Input Impedance> 10 Megohms
Open Thermocouple
   Threshold
   Pulse

18,000 Ohms nominal
< 10 microamp pulse for 400 milliseconds

 

Source Ohms & RTD
3 & 4 Wire Accuracy
   From 1 to 10.2 mA
External Excitation Current
  
   Below 1 mA of External
Excitation Current
2 Wire Accuracy*

±(0.015% of Reading + 0.05 Ohms)


±(0.015% of Rdg +         0.025 mV           + 0.05 Ohms)
                           mA Excitation Current
Add 0.1 Ohms to 3 Wire & 4 Wire Accuracy
Resistance Ranges400 Ohm Range: 0.00 to 401.00 & 0.000 to 401.000
4000 Ohm Range: 0.0 to 4010.0 & 0.00 to 4010.00
RMS Noise400 Ohm Range: ≤ ± 0.005 Ohms from 0.1 to 10 Hz
4000 Ohm Range: ≤ ± 0.05 Ohms from 0.1 to 10 Hz
Allowable Excitation
Current Range
0 to 400 Ohm: 10.2 mA max; steady or pulsed/intermittent
401 to 4000 Ohms: 1 mA max; steady or pulsed/intermittent
Pulsed Excitation
Current Compatibility
DC to 0.01 second pulse width

 

Read Ohms & RTD
3 Wire & 4 Wire Accuracy
2 Wire Accuracy*
±(0.015% of Reading + 0.05 Ohms)
±(0.015% of Reading + 0.15 Ohms)
Resistance RangesSame as Source Ohms & RTD
Excitation Current0.9 mA to 401 Ohms, 0.4 mA to 4010 Ohms (nominal)

* 2 Wire specifications do not include resistance of the lead wires