PIECAL 532 4-20 mA/Voltage Loop Calibrator with Loop Diagnostics

SKU
PIE-532
Manufacturer:
PIECAL
PIECAL

Key Features:

  • True ±0.012% of reading accuracy
  • Source and Read 0.000-24.000 mA
  • Simulate 2-Wire Transmitters
  • Power 2-Wire Transmitters and Read 0.000-24.000mA
  • Display current in mA or -25.00-125.00 % of 4-20 mA
  • Read 0.00 to ± 30.00 VDC with 4X over range ability
  • Source 0.000 to 24.000 VDC with up to 20mA output
  • Direct Calibration 1.000V to 5.000V
  • Auto Step or Ramp
  • Selectable step sizes, time in-between steps & soak time
  • Stop watch like EZ-Check™ switch
  • Full 5 Digit Display
  • Uses 1 – 9Volt alkaline battery
  • Superior battery life of 40 hours under typical continuous usage
  • Easy access to battery compartment
  • 240 VAC Tolerant
  • HART® protocol compatibility mode
  • Power on selectable 250Ω resistor in series with the output for compatibility with HART® protocol enabled devices.
Product Options:
$1,989.00

Secured and trusted checkout with

Calibration, test, and diagnosing process loops. The PIECAL 532 is the best tool to do that!

Practical Instrument Electronics has introduced their PIE 532 loop calibrator. Offering all the functions of a loop calibrator, the 532 also delivers essential troubleshooting tools.

The 532 features the innovative Loop Diagnostic Mode, offered exclusively by PIE. The Loop Diagnostic Mode removes the need for a DMM by  displaying the voltage, loop current, impedance, AC voltage and mode of operation simultaneously for the most in time efficiency. It’s capable of measuring ground fault error as a result of faulty wiring, flooded conduit and corrosion bridges. The unique diagnostic tool, available in every mode of operation, constantly updates parameters in real time and can even identify the most likely cause of loop failure.

With its Loop Diagnostic Mode, EZ-Dial knob for making adjustments, and the Dual Action EZ-Check switch for testing limits, the 532 from Practical Instrument Electronics is one of the leading Loop Calibrators available.

General Specifications:
(Unless otherwise indicated all specifications are rated from a nominal 23 °C, 70 % RH for 1 year from calibration)
Operating Temperature Range-20 to 60 °C (-5 to 140 °F)
Storage Temperature Range-30 to 60 °C (-22 to 140 °F)
Relative Humidity Range10 % ≤RH ≤90 % (0 to 35 °C), Non-condensing
10 % ≤RH≤ 70 % (35 to 60 °C), Non-condensing
Size7.00 X 3.30 X 2.21 inches (177.8 x 83.8 x 56.1mm)
Weight12.0 oz (340 grams)
Battery9V Alkaline
Optional 120 VAC 50/60 Hz AC adaptor available
MiscellaneousLow battery indication with nominal 1 hour of operation left
Over-voltage protection to 120 Vrms (rated for 30 seconds) or 240 Vrms (rated for 15 seconds)
Bar graph display with 1% resolution of 4-20 mA signal scale
High contrast graphic liquid crystal display with 0.45” (11.4 mm) high digits

 

Common Specifications for all Current Modes:
Ranges
Accuracy
Temperature Effect
Resolution(s)
0.000 to 24.000 mA, -25.00 to 125.00% of 4-20 mA
≤ ± (0.012 % of reading + 0.002 mA)
≤ ± 50 ppm/°C of range
0.001 mA and 0.01 %

 

Source/Power and Measure 2-Wire Transmitter Specifications:
Loop Compliance Voltage≥ 24 Volts
Loop Drive Capability1200 Ω at 20 mA for entire battery life, 950Ω w/HART® mode enabled
MiscellaneousOpen loop or out of compliance conditions are indicated by appropriate error display
Battery life in:
Source mode ≥ 18 hrs at 12mA typical (HART® disabled)
Power measure ≥ 10 hrs at 12mA typical
HART® protocol mode is a selectable option at turn on. HART® protocol mode places a 250Ω
resistor in series with the output
Selectable EZ-Step(s) for Source Mode/2-Wire Transmitter Simulation:
2 to 16 selectable step settings
           Step size is determined by the selected high & low ranges
Selectable time settings for stepping and soak:
STEP: 5 to 900 seconds SOAK: 0 to 900 seconds

 

Read mA Specifications:
Voltage Burden
Overload/Current Limit Protection
Battery Life
≤ 2V at 20 mA
nominal ≤24 mA
typical ≥ 40 Hours

 

2-Wire Transmitter Simulation Specifications:
Voltage Burden≤ 2 V at 20 mA
Overload/Current Limit Protectionnominal ≤ 24 mA
Loop Voltage Limits2-60 VDC
MiscellaneousOpen loop or out of compliance conditions are indicated by appropriate error display
Battery life ≥ 40 hour typical
Selectable EZ-Step(s) for Source Mode/2-Wire Transmitter Simulation:
2 to 16 selectable step settings
           Step size is determined by the selected high & low ranges
Selectable time settings for stepping and soak:
STEP: 5 to 900 seconds SOAK: 0 to 900 seconds

 

Voltage Specifications (Read Range):
Read Range:0.000 to 24.000 VDC then 24.01 to 30.00 (with 4X over range) Auto Ranging
Resolutions0.001 V up to 24 V, 0.01 V up to 30.00 V
Temperature Effect≤ ± 100 ppm/°C of range
Input Resistance≥ 1 MΩ
Accuracy0.000 to 24.000 VDC ≤ ± (0.012%RDG + 0.004 V)
24.01 to 30.00 VDC ≤ ± (0.025 % of reading ±0.04 V)

 

Voltage Specifications (Source Range):
Source Range:
Output Resistance
Source Current
Accuracy
Battery life
0.000 to 24.000 VDC
≤0.3 Ω
≥20.000 mA with Flashing indicator for over range
≤±(0.012%RDG + 0.004 V) ±50ppm/°C of range
> 40 hour typical
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account