The MadgeTech HiTemp140-FR is capable of recording up to 4Hz and the probe is capable of measuring from -328 °F to +500 °F.
The HiTemp140-FR is a high temperature data logger that records temperature during quick changing thermal processes. This data logger is capable of recording up to 4Hz in which it allows the temperature sensor to quickly adapt and accurately record temperature variations in changing environments. The probe is equipped for measuring from -328 °F to +500 °F.
The Trigger Settings allows users to configure high and low temperature limits that when met or surpassed, will automatically start or stop recording data to memory. The HiTemp140-FR is capable of storing up to 32,700 date and time stamped readings and features a nonvolatile strong state memory which holds information regardless of the fact that the battery becomes discharge.
HiTemp140-FR-TSK Features
- • Withstands Temperatures between
-200 ºC up to 250 ºC - • Submersible
- • Vented or Flush Enclosure Options
Benefits
- • Validate a Wide Range of Temperature Processes Using One Data Logger
- • Durable Thermal Shield Protects Probe and Allows for a Fast Response Time
Software Features
- • Multiple graph overlay
- • Statistics
- • Digital calibration
- • Zoom in/ zoom out
- • Lethality equations (F0, PU)
- • Mean Kinetic Temperature
- • Full time zone support
- • Data annotation
- • Min./Max./Average lines
- • Data table view
- • Automatic report generation
- • Summary view
- • Multilingual
Software
HITEMP140-FR Specifications
Temperature
Temperature Sensor: | 100 Ω Platinum RTD |
Probe Measurement Range: | -200 ºC to +260 ºC (-328 ºF to +500 ºF) |
Temperature Resolution: | 0.01 ºC (0.02 ºF) |
Calibrated Accuracy: | ±0.1 ºC/±0.18 ºF (20 ºC to +140 ºC/68 ºF to +284 ºF) |
General
Data Logger Response Time: | In Air t60 - 0:00:39 t90 - 0:02:43 | In Water t60 - 0:00:10 t90 - 0:00:12 |
Reading Rate: | 4 readings per second up to 1 reading every 24 hours | |
Memory: | 32,767 readings | |
Start Modes: | •Software programmable immediate start •Delay start up to 18 months in advance | |
Stop Modes: | Manual or Timed (specific date and time) | |
Trigger Settings: | High & Low limits may be set. Once data meets or exceed sets limits, the device will record to memory. Bi-level start and stop triggers can also be programmed. Users can specify the number of readings to take after the device triggers. | |
Readings in Trigger Settings Mode: | 10,922 readings | |
Real Time Recording: | May be used with PC to monitor & record data in real time | |
Password Protection: | An optional password may be programmed into the device to restrict access to configuration options. Data may be read without the password. | |
Memory Wrap Around: | Yes | |
Battery Type: | 3.6V high-temperature lithium battery included; user replaceable | |
Battery Life: | 2 years typical (1 minute reading rate) | |
Calibration: | Digital calibration through software | |
Calibration Date: | Automatically recorded within device | |
Data Format: | Date and time stamped °C, °F, °R, K | |
Time Accuracy: | ±1 minute/month at 25 ºC Extended Operation: ±20 minutes/month at 140 °C (±450 ppm) | |
Computer Interface: | IFC400 or IFC406 USB docking station required; 125,000 baud | |
Operating System Compatibility: | XP SP3/Vista/Windows 7/Windows 8 | |
MadgeTech Software Compatibility: | •MadgeTech Standard Software version 4.2.3.0 or later •MadgeTech Secure Software version 4.2.2.0 or later | |
Operating Environment: | -40 ºC to +140 ºC (-40 ºF to +284 ºF), 0 %RH to 100 %RH, 0.002 PSIA to 100 PSIA | |
IP Rating: | IP68 | |
Dimensions (body): | 1.89 in x 0.970 in x 0.970 in (48 mm x 24.6 mm x 24.6 mm) | |
Dimensions (probe): | 1.75 in x 0.0625 in dia. (0.188 in transitional dia.) 44.5 mm x 1.59 mm (4.78 mm Transitional dia.) | |
Weight: | 65 g (2.3 oz) | |
Materials: | 316 Stainless Steel, PEEK | |
Approvals: | CE |
HITEMP140-FR-TSK Specifications
Data Logger Response Time with Thermal Shield: | HiTemp140-FR-TSK (Flush) | HiTemp140-FR-TSK (Vented) | ||
Exposure Time in Air | Exposure Time in Water | Exposure Time in Air | Exposure Time in Water | |
t60 - 0:00:30 | t60 - 0:00:09 | t60 - 0:00:59 | t60 - 0:00:10 | |
t90 - 0:13:10 | t90 - 0:00:12 | t90 - 0:22:10 | t90 - 0:00:12 | |
Dimensions (enclosure): | 2.75 in x 2.0 in dia. (69.85 mm x 51 mm dia.) | 4.3 in x 2.0 in dia. (109.2 mm x 50.8 mm dia.) | ||
Weight: | 6.7 oz (190 g) not including data logger | 9.5 oz (270 g) not including data logger | ||
Operating Environment: | -200 ºC to +250 ºC (-328 ºF to +482 ºF) (Time limited) 0 %RH to 100 %RH | |||
Material: | Enclosure: PTFE |
Dimensions
- • Autoclave Verification and Mapping
- • Seafood Processing: Smoked Lobsters, Shellfish & Shrimp
- • Steam Sterilization
- • Oven Profiling
- • Roasting
- • Flash Freezing
- • Frying