  • Maximum capacity: 7.0 GPH (26.5 l/h)
  • Maximum pressure: 30 PSIG (2.07 Bar)
  • Stroke speed and stroke length able to be manually adjusted
  • Encapsulated electronics defend against moisture and corrosive conditions
  • NEMA 4X / IP65 enclosure
  • Reliable electronics provide continuous dependable, repeatable performance
  • UL, CUL, NSF 50, NSF 61, CE Certifications
Product Options:
Call For Price

Secured and trusted checkout with

The LMI Series B Chemical Metering Pumps is delivering the model B14 with a 7.0 GPH (26.5 l/H) maximum capacity and a 30 PSIG (2.07 Bar) maximum pressure. More still, the B14 features a stroke length and speed that are both manually adjustable.

Gallons per Hour*

Liters per Hour*

mL/cc per  Minute*

mL/cc per Stroke

Maximum Injection Pressure

Min             Max

Min           Max

Min              Max

Min               Max

0.007            7.0

0.027         26.5

0.44             442

0.44               4.42

30 psi    (2.07 Bar)

*Minimum output is based on 1 stroke per minute and 10% stroke setting, minimum output can be reduced further in external mode. B9 pumps may be programmed for strokes per hour for lower outputs.

 

Strokes per Minute

(Adjustable)

Stroke Length

(Adjustable)

Recommended Minimum

Average Input Power at Max Speed

Shipping Weight

Min                  Max

1                      100

10%

29 watts

15 lbs (6.9 kg)

 

Liquid End Specifications:

LIQUIPRO Liquid Ends

Liquid End

Head / Fittings

Balls

Liquifram

Cartridge Valve or Seal Rings

Accs. Valve

Tubing & Connections

312HI*

PVDF / PVDF

.375 Ceramic

Fluorofilm™

PVDF/ Polyprel®

AV+4FV

PE .5" O.D.

312SI*

PVDF / PVDF

.375 Ceramic

Fluorofilm™

PVDF/ Polyprel®

4FV

PE .5" O.D.

312TI*

PVDF / PVDF

.375 Ceramic

Fluorofilm™

PVDF/ Polyprel®

3FV

PE .5" O.D.

313HI*

PVDF / PVDF

.375 Ceramic

Fluorofilm™

PVDF/ PTFE

AV+4FV

PE .5" O.D.

313SI*

PVDF / PVDF

.375 Ceramic

Fluorofilm™

PVDF/ PTFE

4FV

PE .5" O.D.

313TI*

PVDF / PVDF

.375 Ceramic

Fluorofilm™

PVDF / PTFE

3FV

PE .5" O.D.

318SI*

PVC / PVC

.375 Ceramic

Fluorofilm™

PVDF/ Polyprel®

4FV

PE .5" O.D.

318TI*

PVC / PVC

.375 Ceramic

Fluorofilm™

PVDF/ Polyprel®

3FV

PE .5" O.D.

410SI*

Acrylic / PVC

.375 Ceramic

Fluorofilm™

PVDF/ Polyprel®

4FV

PE .5" O.D.

410TI*

Acrylic / PVC

.375 Ceramic

Fluorofilm™

PVDF/ Polyprel®

3FV

PE .5" O.D.

415NI*

Polypropylene

Ceramic

Fluorofilm™

PTFE

-

PE .5" O.D.

415SI*

Polypropylene

Ceramic

Fluorofilm™

PTFE

4FV

PE .5" O.D.

418SI*

PVC / PVC

.375 Ceramic

Fluorofilm™

PVDF/ Polyprel®

4FV

PE .5" O.D.

418TI*

PVC / PVC

.375 Ceramic

Fluorofilm™

PVDF/ Polyprel®

3FV

PE .5" O.D.

419SI*

Acrylic / PVDF

.375 PTFE

Fluorofilm™

PVDF/ Polyprel®

4FV

PE .5" O.D.

 

LMI Liquid Ends

Liquid End

Head / Fittings

Balls

Liquifram

Cartridge Valve or Seal Rings

Tubing & Connection

217

316 S.S.

316 S.S.

Fluorofilm

316 S.S.

Pipe 1/4" NPT M

 3FV indicates that the pump is equipped with an LMI Three Function Valve (pressure relief, priming aid, line drain).

4FV indicates that the pump is equipped with an LMI Four Function Valve. This diaphragm type, anti-syphon/pressure relief valve is installed on the pump head. It provides anti-syphon protection and aids in priming, even under pressure.

* - These liquid ends use 3/8 diameter valve balls. Pump output may be reduced in some applications.

AUTOPRIME Liquid Ends

AUTOPRIME liquid ends are used in applications with off-gassing liquids such as Sodium Hypochlorite

Liquid End

Head / Fittings

Balls

Liquifram

Seat / O Rings

Accs. Valve

Tubing & Connections

D10HI

Acrylic / PVC

Ceramic

Fluorofilm

Polyprel

4FV

PE 1/2" O.D.

D10AI

Acrylic / PVC

Ceramic

Fluorofilm

Polyprel

-

PE 1/2" O.D.

D18HI

PVC / PVC

Ceramic

Fluorofilm

Polyprel

4FV

PE 1/2" O.D.

D18AI

PVC / PVC

Ceramic

Fluorofilm

Polyprel

-

PE 1/2" O.D.

 AUTOPRIME liquid ends have 3 check valves: Suction on the bottom; Discharge on the front; Autoprime bleed on the top. By design, a repeatable portion of the process fluid continuously bleeds through the top check valve to be returned to the chemical supply. The result is the assurance that any gas in the head is automatically relieved thus eliminating air-binding. Depending on application, output may be reduced up to 50%. Variables include supplier piping, stroke length and speed setting. The maximum output per the tables above is reduced to account for the continuous bleed.

By design, a repeatable portion of the process fluid continuously bleeds through the top check valve to be returned to the chemical supply.

Output Information with AutoPrime Liquid End - Estimated

GPH

Liters/hr

mL/cc per  Minute

mL/cc per Stroke

Maximum Pressure

6.8

25.7

429.1

4.29

30 psi    (2.07 Bar)

 

 