Climomaster TMSpecifications | ||
Air Velocity | Range Accuracy Resolution | 10 to 9840 FPM (0.01 to 50.0 m/s) *Varies by probe 0.01 m/s (0.01 to 9.99 m/s), 0.1 m/s (10.0 to 50.0 m/s) |
Temperature | Range Accuracy Resolution | -4 to 158°F (-20 to 70°C) +/- 1.0°F (0.5°C) 1.0°F (0.1°C) |
Humidity | Range Accuracy Resolution | 2.0 to 98.0 %RH *Varies by probe +/- 2.0 %RH 0.1 %RH |
Pressure (Option) | Range Accuracy Resolution | -5.00 to +5.00 kPa 0.01 kPa |
Interface | Digital Analog (Option) | USB and RS232C (for print-out) |
Data Storage Capacity | Up to 20,000 records | |
Power Supply | 6 x AAbatteries or AC Adapter | |
Operation Range | Main Unit Probe Storage | 41 to 104 °F (5 to 40°C) with no visible condensation |
Weight | 0.9 lbs (400 g) | |
Dimensions | Main Body: 3.4 x 7.4 x 1.6 inches (88 x 188 x 41 mm) | |
Warranty | 2 years |
Model | 6531 | 6541 | 6542 | 6551 | 6552 | 6533 | 6543 | 6561 | |
Air Velocity | Range | 20 to 6000 fpm (0.10 to 30.0 m/s) | 10 to 1000 fpm (0.05 to 5.00 m/s) | 20 to 9840 fpm (0.1 to 50 m/s) | |||||
Accuracy | +/- (2% of reading +/- 0.0125) m/s | ||||||||
Air Temperature | Range | -4 to 158°F (-20 to 70°C) | |||||||
Accuracy | +/- 1°F (+/- 0.5 °C) | ||||||||
Relative Humidity | Range | 2 to 98%RH (Model A531, A533) | |||||||
Accuracy | +/- 2 %RH | ||||||||
Differential Pressure (Option) | Range | -5.00 to +5.00 kPa | |||||||
Accuracy | +/- (3% of reading +0.01) kPa | ||||||||
Output | Digital | USB | |||||||
Analog | DC 0 to 1 V (Option) | ||||||||
Datalogging | Stores up to 20000 measurement data | ||||||||
Power Supply | 6 x AA Batteries / AC Adapter (100 to 240 V) | ||||||||
Weight | 0.9 lbs (400 g) | ||||||||
Standard Accessories | Carrying Case, Operation Manual, AA Batteries, 2m Probe Cable, NIST Certificate | ||||||||
Option | Spare Probes, Analog Output, Pressure Sensor, Extention Rod Printer, Printer Cable, PC Communcation Cable, Windows Software, AC Adapter |
Probe Selection Guide
Probe | Measuring Range (fpm) | Probe Type | Directivity | Velocity | Temperature | Relative Humidity |
6531-2G | 20 to 6000 | Rod | Mono | O | O | O |
6541-2G | 20 to 6000 | Rod | Mono | O | O | x |
6561-2G | 20 to 9840 | Rod | Mono | O | O | x |
6542-2G | 20 to 6000 | Needle | Omni | O | O | x |
6533-2G | 10 to 1000 | Spherical | Omni | O | O | O |
6543-2G | 10 to 1000 | Spherical | Omni | O | O | x |
6551-2G | 20 to 6000 | Miniture | Omni | O | x | x |
6552-2G | 20 to 6000 | Miniture | Omni | O | x | x |
Probe Specifications
Probe | Applications | Probe Tip |
6531-2G | 20 to 6000 HVAC Testing, IAQ Investigation | |
6541-2G | 20 to 6000 HVAC Testing | |
6561-2G | 20 to 9840 High Velocity Applications | |
6542-2G | 20 to 6000 HVAC Testing, Manufacturing Process Control | |
6533-2G | 10 to 1000 Cleanroom Certification, HEPA Filter Performance Testing, Turbulent Air Testing | |
6543-2G | 10 to 1000 Cleanroom Certification, HEPA Filter Performance Testing, Turbulent Air Testing | |
6551-2G | 20 to 6000 Heat Sink Cooling Efficiency Testing, Airflow Measurements in tight spaces | |
6552-2G | 20 to 6000 Heat Sink Cooling Efficiency Testing, Airflow Measurements in tight spaces |
- • HVAC Ventilation Testing and Balancing
- • Laboratory Control
- • Fume Hood Performance Testing
- • IAQ Investigation
- • Industrial Flow Testing