We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
Part of the IPAQ C520 series, Inor Transmitter’s IPAQ C520XS temperature transmitter is intrinsically safe for use in Ex-Zone 1 and 2. The transmitter is compatible with the HART 6 protocol and is both isolated and universal.
Configured with a dual sensor input for RTD, resistance or thermocouple, the transmitter’s features like the sensor backup and sensor drift monitoring all work to heighten efficiency and simplify operation.
Not only is the IPAQ C520XS prominent for superior accuracy and stability, based on a hardware assessment according to IEC 61508-2, consisting of a FMEDA done by Exida, the C520XS is suitable for use in SIL 2 rated Safety Instrumented Systems (SIS), making it an overall value from Inor Transmitter.
Type | Head-mounted |
Input | RTD; Thermocouple; Universal |
Input RTD | Pt10, Pt50, Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000, Cu10 |
Input Thermocouple | Type B, C, D, E, J, K, N, R, S, T |
Type Of Transmitter | Digital |
Output | 4-20 mA; HART® |
Isolation | Isolated |
Measuring channels | 2 channels |
Input connections | 2-, 3-, 4- wire connection |
Power supply | IPAQ C520/C520S: 10 to 36 VDC; IPAQ C520X/C520XS: 10 to 30 VDC |
Approvals | ATEX, IECEx, SIL2 |
Typical accuracy | RTD: Max. of ±0.1 °C or ±0,05 % of span; TC: Typical ±0.05 of span |
Quick delivery | Yes |
Products In This Series
As low as
Now $430.00