We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
The Fluke Networks MT-8200-63A probe detects IntelliTone digital signals on active networks and 500 to 1200 Hertz analog signals on inactive networks to locate, trace, and isolate copper cabling.
Click Here if you want the IntelliTone Pro 200 LAN Toner and Probe Kit
GENERAL SPECS | |
Operating temperature | 32 °F to 104 °F (0 °C to 40 °C) |
Storage temperature | -4 °F to +140°F (-20 °C to °C) |
Operating relative humidity (% RH without condensation) | 95 % (50 °F to 95 °F; 10 oC to 35 °C) 75 % (95 °F to 104 °F; 35 °C to 40 °C) Uncontrolled < 50 °F (< 10 °C) |
Vibration | Random, 2 g, 5 Hz-500 Hz |
Shock | 1 m drop test |
Safety | EN 61010-1, Category: None |
Altitude | 3000 m |
EMC | EN 61326-1, FCC Part 15 B |
Battery type and life | 9 V alkaline (NEDA 1604A or IEC 6LR61); 20 hours typical |
Applications | Copper cabling media including; 75 or 50 Ohm Coaxial cable; Two Conductor control, security, generic cabling. 10 Base-T or 10/100 Base-T datacom networks. UTP cable. Shielded Twisted Pair supported in Cablemap function of the IntelliTone 200. |
PROBE SPECS | |
Dimensions | 8.73 in x 1.88 in x 1.26 in (22.2 cm x 4.8 cm x 3.2 cm) |
Display | (8) LED indicators, Sync LED indicator |
Audio | IntelliTone: Microprocessor controlled audio files Analog: Detected toner signal |
Control | Thumbwheel switch, volume control wheel |
Tone detection | Detects IntelliTone™ digital signal for Locate, Isolate, and CableMap Detects analog SmartTone signal (500-1200Hz) and other analog toners. |
Toner interface | Main Mod8 port for cablemap on all 4 pairs of UTP / STP cabling. |
Auto power down | Turns off automatically after 1 hour of inactivity |