The Fluke Networks 30800009 TS30 test set has the same features as the 30800001 but instead of coming with piercing pin clips the 30800009 come with Angled Bed-of-Nails (ABN) clips.
Electrical | |
Return Loss | >14 dB (ref 600 Ω) |
Line Current Range | 15 mA to 120 mA |
Resistance to Continuous Current (Talk Mode) | 275 Ω typical at 20 mA |
Monitor Mode Impedance | >120,000 Ω 300 Hz to 3400 Hz |
Pulse Dial Output | |
Pulsing Rate | 10 pps ±1 pps |
Open/Close Ratio | 60/40 |
Inter-digit Interval | 800 ms +20%, -10% |
Resistance During Pulse Open | > 200,000 Ω |
Protection Against Alternating Current Overvoltage | The TS30 survives up to 300 Vrms across its test leads. |
Peak Acoustic Output of the Receiver | <120 dBspl |
DTMF Output Tone Frequencies Tone Frequency Error | per ITU-T Q.23 ±1.5% Maximum |
Tone Level | |
High Group Low Group | -4 dBm (into 600 Ω) -6 dBm (into 600 Ω) |
High vs Low Tone Difference | 2dB ±1db |
Last Number Redial (Tone/Pulse) | |
Memory Capacity Memory Retention | 23 digits 8-minutes nominal |
Flash Duration | 600 ms ±100 ms |
Ringer Loudness | > 70 dBA at 1 meter |
Ringer Equivalent (REN) | 0.14 |
Measurements | 10 in x 2.83 in x 3.34 in (25.5 cm x 7.2 cm x 8.5 cm) |
Weight | 16.8 ounces (0.476 kg) |
Environmental | |
Temperature Operating Storage | -4 °F to +140 °F (-20°C to +60°C) -40 °F to +151 °F (-40°C to +66°C) |
Relative Humidity | 5% to 95% |
Safety | |
Telecom Electrical | TNV-3 |
Safety Classification | IP54 |
Regulatory Standards Used | |
47 CFR Part 15, Subpart B ICES-003 Issue 3 AS/NZS 3548 EMC Directive 89/336/EEC, EN 55022:98, EN 61326:97, A1:98 Annex C, EN 61000-4-2, EN 61000-4-3 LV Directive 73/23/EEC, EN 610010.1 (1993) | |
Certifications and Compliance | |
Safety | |
IEC 61010-1:2010, Pollution Degree 2, Category: None Complies with CAN/CSA-C22.2 No. 61010-1 | |
EMC | |
IEC 61326-1 (Portable), IEC 61326-2-2, CISPR 11 (Group 1, Class A) Group 1 equipment: group 1 has intentionally generated and/or use conductively coupled radiofrequency energy which is necessary for the internal functioning of the equipment itself. Class A equipment is equipment suitable for use in all establishments other than domestic and those directly connected to a low voltage power supply network which supplies buildings used for domestic purposes. USA (FCC) – 47 CFR 15 subpart B, this product is considered an exempt device per clause 15.103 |