The Fluke Networks 26500090 TS90 is an easy-to-use cable fault locator, cable and wire manager, and tone generator. The TS90 lets you easily find the distance to opens or shorts on electrical wire, telephone wire, security wire and coax. The TS90 has SmartTone technology that gives you 5 distinct tones to use for exact wire and pair identification, even in proximity to current-bearing cable.
General Specifications | |
Power of operation | 4 AA alkaline batteries, provide 50 hours |
Reverse Battery Protection | No damage to the tester will occur if the batteries are installed backwards. |
Input Protection | 250 V rms ac, continuous or intermittent |
Moisture | If the tester is exposed to water, some may get inside, but it will suffer NO DAMAGE. See the moisture notes in the Maintenance section. |
Impedance Range | 35 Ω to 330 Ω with auto-compensation within this range. Cables with an impedance outside this range will not be properly tested and may produce erratic or incorrect readings. |
Maximum Length | 2500 feet on most cable types, and 500 feet on very lossy cables. The tester will feet on very lossy cables. The tester will display –Err if the cable is too long to be correctly measured. |
Representative Maximum Cable Length | 2500 feet: CAT-5 Twisted Pair 2000 feet: 12/2 ac Wire 1000 feet: RG-6/U TV Coax 500 feet (150 meters): RG-174/U Coax |
Minimum Length | No minimum length. Minimum non-zero reading is 2 feet. |
Length Accuracy | ±2 feet for cables less than 10 feet ±5 feet for cables longer than 10 feet and shorter than 200 feet ±3 % and ±5 feet for cables longer than 200 feet |
High Voltage Detection | An ac voltage of more than 5 V rms will trigger the High Voltage Warning. |
Measurement Rate | Maximum of 4 complete measurements per second, decreasing to 2 seconds per measurement based on cable size and uniformity. |
VOP | Adjustable from -20- to -99-, retained during power off. Default to -66- when batteries are changed. |
Measurement Technology | Time Domain Reflectometry (TDR) with 50 Ω drive impedance, 6 V maximum pulse height. |
Low Battery | Indicator flashes when battery voltagefalls below 4.1 V |
Tone Injection | Approximately 1 kHz at an amplitude of 80 % of battery voltage. Variable frequency and cadence. Tone characteristic is changed as cable condition changes to “normal-open” from any other condition. |
Cable Type | Virtually all two or more conductor cables |
Temperature Range Operating Storage | 32 °F to 131 °F (0 °C to 55 °C) -40 °F to 158 °F (-40 °C to 70 °C) |
Humidity Operating Storage | 0 % to 80 % 0 % to 100 % |
Weight | 1 lb with batteries and clip leads |
Operating Altitude | 10,000 ft max |
Certifications and Compliance | Conformité Européenne. Conforms to relevant European Union directives. CAN/CSA-C22.2 No. 60950-1-03 CAN/CSA-C22.2 No. 1010.1-92 CSA-C22.2 No. 1010.1B-97, UL/ANSI 3111-1 |