We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
Optimized for the world you work in, the VT04 Visual IR Thermometer Maintenance Kit includes:
This kit:
The VT04 Visual IR Thermometer provides a built in digital camera with a thermal heat map overlay to detect hot and cold spots instantly. The VT04 eliminates the tedious task of recording multiple measurements manually.
Hot and cold spot trackers and temperature alarms help you measure with confidence knowing that you did not miss a hot or cold spot. In addition, the VT04:
The Fluke 1507 Insulation Tester is compact, rugged, reliable, and easy to use for professional insulation diagnostics. With its multiple test voltages, the 1507 is ideal for many troubleshooting, commissioning, and preventive maintenance applications. Additional features, like the remote probe on these tools, save both time and money when performing tests.
Stretch your dollar further, increase your productivity on the job and expand your business by documenting needed repairs with the VT04 Visual IR Thermometer Maintenance Kit.
Fluke VT04 Visual IR Thermometer
Key Features | |
Built-in digital camera | Yes |
Thermal heat map overlay | Yes, five blending modes |
Image optics system | PyroBlend™ Plus optic *4x sharper image than VT02 |
Field of view | 28° x 28° |
Hi-Lo temperature alarms | Yes |
Time lapse image capture | Yes |
Auto-monitor alarm | Yes |
Battery type | Li-Ion rechargeable |
Training | No training required |
Ergonomics | Slim pocket-sized design |
Hot and cold markers | Yes |
General Features | |
Battery life | Eight (8) hours |
Temperature measurement range | -10 °C to +250 °C (14 °F to 482 °F) |
Temperature measurement accuracy | +/- 2 °C or +/- 2 % |
Temperature measurement | Yes, centerpoint |
Storage medium (micro SD card) | Stores up to 10,000 images per Gb (Four (4) Gb card included) |
Infrared spectral band | 6.5 μm to 14 μm |
Level and span | Auto |
Focus mechanism | Focus free, no training required with built-in intelligence |
Focus options-exclusive user selectable NEAR/FAR options | NEAR < 23 cm (9 in); FAR > 23 cm (9 in) |
Dimensions | 21 cm x 7.5 cm x 5.5 (8.3 in x 3 in x 2.2 in); < 300 g. (10.5 oz.) |
File format | .is2 format saved to SD card. User can create professional reports or export images in SmartView (BMP, DIB, GIF, SPE, FIF, SPEG, JPG, PNG, TIF and TIFF) |
Safety and compliance | CFR47: 2009 Class A. Part 15 subpart B; CE: EN 61326:2006; IEC/EN 61010-1:2010 |
Warranty | Two (2) years |
Fluke 1507 Insulation Resistance Testers
AC/DC Voltage Measurement | ||
Accuracy | Range | 600.0 V |
Resolution | 0.1 V | |
50 Hz to 400 Hz ± (% of Rdg + Digits) | ± (2 % + 3) | |
Input impedance | 3 MΩ (nominal), < 100 pF | |
Common mode rejection ratio (1 kΩ unbalanced) | > 60 dB at dc, 50 or 60 Hz | |
Overload protection | 600 V rms or dc |
Earth Bond Resistance Measurement | ||
Range/Resolution | 20.00 Ω | 0.01 Ω |
200.0 Ω | 0.1 Ω | |
2000 Ω | 1.0 Ω | |
20.00 kΩ | 0.01 kΩ | |
Accuracy | ± (1.5 % + 3) | |
Overload protection | 2 V rms or dc | |
Open circuit test voltage | > 4.0 V, < 8 V | |
Short circuit current | > 200.0 mA |
Insulation Specifications | ||
Measurement range | 0.01 MΩ to 10 GΩ | |
Test voltage | 50 V, 100 V, 250 V, 500 V, 1000 V | |
Test voltage accuracy | + 20 %, - 0 % | |
Short circuit current | 1 mA nominal | |
Auto discharge | Discharge time < 0.5 second for C = 1 µF or less | |
Live circuit indicator | Inhibit test if terminal voltage > 30 V prior to initialization of test | |
Maximum capacitive load | Operable with up to 1 µF load | |
Measure accuracy | 50 V | ±(3 % + 5) |
100 V | ±(3 % + 5) | |
250 V | ±(1.5 % + 5) | |
500 V | ±(1.5 % + 5) | |
1000 V | ±(1.5 % + 5) to 2000 MΩ, ±(10 % + 3) above 2000 MΩ |
General Specifications | ||
Maximum voltage applied to any terminal | 600 V ac rms or dc | |
Storage temperature | -40 °C to 60 °C (-40 °F to 140 °F) | |
Operating temperature | -20 °C to 55 °C (-4 °F to 131 °F) | |
Temperature coefficient | 0.05 x (specified accuracy) per °C for temperatures < 18 °C or > 28 °C (< 64 °F or > 82 °F) | |
Relative humidity | 0 % to 95 % @ 10 °C to 30 °C (50 °F to 86 °F) | |
0 % to 75 % @ 30 °C to 40 °C (86 °F to 104 °F) | ||
0 % to 40 % @ 40 °C to 55 °C (104 °F to 131 °F) | ||
Vibration | Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument | |
Shock | 1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor) | |
Electromagnetic compatibility | In an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1:1997) | |
Safety | Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV) | |
Certifications | CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition | |
Batteries | Four AA batteries (NEDA 15A or IEC LR6) | |
Battery life | Insulation test use | Tester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off. |
Resistance measurements | Tester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off. | |
Size | 5.0 cm H x 10.0 cm W x 20.3 cm L (1.97 in H x 3.94 in W x 8.00 in L) | |
Weight | 550 g (1.2 lb) | |
IP rating | IP40 | |
Altitude | Operating | 2000 m CAT IV 600 V, 3000 m CAT III 600 V |
Non-operating (storage) | 12,000 m | |
Over-range capability | 110 % of range | |
Included accessories | TL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe |