Fluke Calibration 7526A Precision Process Calibrator

SKU
7526A
Manufacturer:
Fluke Calibration
Fluke Calibration

Key Features:

  • Sources and measures dc voltage, current, resistance, RTDs and thermocouples
  • Extend pressure measurement range with any Fluke 750P and 700P Series Pressure Modules
  • Includes 24 V dc transmitter loop power supply
  • Measures 4-20 mA loop current
  • Includes automated switch-test function
  • Accepts ITS-90 coefficients for accurate SPRT measurements
  • Compatible with MET/CAL® Calibration Software
Product Options:
$11,175.00

Secured and trusted checkout with

The Fluke Calibration 7526A Precision Process Calibrator offers the best balance of economy and accuracy for benchtop calibration of temperature and pressure process instrumentation. Easily calibrate RTD and thermocouple readouts, pressure gauges, temperature transmitters, digital process simulators, data loggers, multimeters and more.

DC voltage, output
Range [1]Absolute Uncertainty, ±
(ppm of output + μV), 1-yr
Resolution
0 to 100 mV3031 μV
0 to 1 V301010 μV
0 to 10 V30100100 μV
0 to 100 V301 mV1 mV
TC Output and Input
–10 mV to 75 mV302 μV1 μV

[1] All outputs are positive only unless otherwise noted

DC voltage, isolated input
RangeAbsolute Uncertainty, ±
(ppm of reading + mV),
1-yr
Resolution
0 to 10 V1000.2100 μV
10 V to 100 V1002.01 mV
DC Current, output
Range[1]Absolute Uncertainty,
± (ppm of reading + μA),
1-yr
Resolution
0 to 100 mA5011 μA

[1] For line voltages less than 95 V, ±100 ppm of reading

DC current, isolated input
RangeAbsolute Uncertainty, ±
(ppm of reading + μA),
1-yr
Resolution
0 mA to 50 mA10010.1 μA
0 mA to 24 mA [1][2]
(Loop Power)
10010.1 μA

[1] Loop Power: 24 V ±10%
[2] HART Resistor: 250 Ω ± 3%

Resistance, output
RangeAbsolute
Uncertainty,
tcal ± 5 °C, ±
Ohms, 1-yr
ResolutionNominal
current
5 Ω to 400 Ω0.0150.001 Ω1 to 3 mA
5 Ω to 4 kΩ0.30.01 Ω100 μA to 1 mA
Resistance, input
RangeAbsolute Uncertainty, ±
(ppm of reading + Ω), 1-yr
Resolution
0 Ω to 400 Ω200.0040.001 Ω
0 Ω to 4 kΩ200.040.01 Ω
Sample thermocouple accuracy, input/output
(does not include all available TC types)[1]
TC typeTemperature Range (°C)Absolute Uncertainty,
tcal ±5 °C, ± (°C), 1-yr [2]
MinMax
J-21012000.09
K-25013720.1
S-5017670.29
T-2504000.11

[1] See extended specifications for all TC types (B,C,E,J,K,L,N,R,S,T,U,XK,BP)
[2] Best accuracy within specified TC temperature range

Sample RTD and thermistor, output
(does not include all available RTD types)[1]
RTD TypeTemperature Range (°C)Absolute Uncertainty,
tcal ±5 °C, ± (°C), 1-yr
MinMax
Pt 385, 100 Ω-2006300.05
YSI 40015500.007

[1] See extended specifications for all RTD types: Pt-100 (385, 3926, 3916), Pt- 200, Pt-500, Pt-1000, Ni-120, Cu-427, SPRT

Sample RTD and thermistor, intput
(does not include all available RTD types)[1]
RTD TypeTemperature Range (°C)Absolute Uncertainty,
tcal ±5 °C, ± (°C), 1-yr
MinMax
Pt 385, 100 Ω–801000.020
1003000.024
3008000.038
YSI 40015500.007

[1] See extended specifications for all RTD types: Pt-100 (385, 3926, 3916), Pt- 200, Pt-500, Pt-1000, Ni-120, Cu-427, SPRT

General specifications
Standard interfaceRS-232, IEEE-488 (GPIB)
Temperature
performance
Operating:0 °C to 50 °C
Calibration (tcal):18 °C to 28 °C
Storage:–20 °C to 70 °C
Electromagnetic
compatibility
CE: Conforms to EN61326;
operation in controlled EM environments
Temperature coefficientTemperature coefficient for temperatures
outside tcal 5 °C is 10% of the 90-day
specification (or 1 year if applicable) per °C
Relative humidityOperating:<80% to 30 °C
<70% to 40 °C
<40% to 50 °C
AltitudeOperating:3,000 m (9,800 ft) max
Non-operating:12,200 m (40,000 ft) max
SafetyEN/IEC 61010-1:2010 3rd Edition,
UL 61010-1:2012, CAN/CSA 22.2 No. 61010-1-12
Analog low isolation20 V
Line power120 V~:100 V to 120 V
240 V~:220 V to 240 V
Line frequency47 Hz to 63 Hz
Line voltage variation± 10 % about setting
Power consumption15 VA maximum
DimensionsHeight:14.6 cm (5.75 in)
Width:44.5 cm (17.5 in)
Depth:29.8 cm (11.75 in)
Weight
(without options)
4.24 kg (9.35 lb)