The Fluke 87V MAX incorporates all the renowned features of the most popular DMM used today, the Fluke 87V, in addition to much more.
The Fluke 87V MAX True RMS Digital Multimeter pioneers a new standard for operating in extreme conditions, with the features and accuracy to troubleshoot most electrical problems. The 87V MAX has an IP 67 (waterproof and dustproof) rating, extended operating temperature range of -15 °C to +55 °C (5 °F to 131 °F, -40 °C for up to 20 minutes) and 95 % humidity, and has been crafted and tested to withstand a 4 m (13 ft) drop.
The 87V MAX also has an industrial-strength outer shell and a removable holster that doubles as test lead storage and a test probe holder for one-handed operation.
Electrical Specifications | ||
DC Voltage | Range | 0.1 mV to 1000 V |
Accuracy | ±(0.05% + 1) | |
Maximum resolution | 0.1 mV | |
AC Voltage | Range | 0.1 mV to 1000 V |
Accuracy | ±(0.7% + 4) true-rms | |
AC bandwidth | 20 kHz with low pass filter; 3 dB @ 1 kHz | |
Maximum resolution | 0.1 mV | |
DC Current | Range | 0.1 μA to 10 A (20 A for 30 seconds maximum) |
Amps accuracy | ±(0.2% + 2) | |
Maximum resolution | 0.1 µA | |
AC Current | Range | 0.1 μA to 10 A (20 A for 30 seconds maximum) |
Amps accuracy | ±(1.0% + 2) true-rms | |
Maximum resolution | 0.1 µA | |
Resistance | Range | 0.1 Ω to 50 MΩ |
Accuracy | ±(0.2% + 1) | |
Maximum resolution | 0.1 Ω | |
Capacitance | Range | 0.01 nF to 9999 μF |
Accuracy | ±(1% + 2) | |
Maximum resolution | 0.01 nF | |
Frequency | Range | 0.5 Hz to 199.99 kHz |
Accuracy | ±(0.005% + 1) | |
Maximum resolution | 0.01 Hz | |
Duty cycle | Maximum duty cycle | 99.9% |
Accuracy | ±(0.2% per kHz + 0.1%) | |
Maximum resolution | 0.1% | |
Temperature measurement range | –200.0 °C to 1090 °C –328.0 °F to 1994.0 °F excluding probe | |
80 BK temperature probe | –40.0 °C to 260 °C, ± 2.2 °C or 2% whichever is greater –40.0 °F to 500 °F, ± 4.0 °F or 2% whichever is greater | |
Conductance | Maximum conductance | 60.00 nS |
Accuracy | ±(1.0% + 10) | |
Maximum resolution | 0.01 nS | |
Diode test | Range | 2 V |
Resolution | 0.001V | |
Accuracy | ±(1% + 1) | |
Diagnostics and data storage | Peak Min/Max | 250 μS |
Min/Max/Avg | Yes | |
Reading hold/Auto (Touch) Hold | Yes | |
Relative reference | Yes | |
Display | Digital | 6000 counts updates 4/second 19,999 counts in high–resolution mode |
Analog bar graph | 32 segments, updates 40/second | |
Backlight | Two level | |
Low pass filter (VFD measurements) | Yes | |
Input Alert™ | Yes | |
Safety Specifications | ||
Safety rating | IEC61010-1: Pollution Degree 2 IEC 61010-2-033: CAT IV 600 V, CAT III 1000 V | |
Agency approvals | CE, CSA | |
Mechanical and General Specifications | ||
IP rating | IEC 60529: IP67 | |
Power | Three AA batteries. 800 hours typical, without backlight | |
Size | 6.0 x 10.1 x 21.5 cm (with holster) | |
Weight | 698.5 g (with holster) | |
Warranty | Limited lifetime | |
Environmental Specifications | ||
Operating temperature | -15 °C to 55 °C, to -40 °C for 20 minutes when taken from 20 °C | |
Storage temperature | -40 °C to + 60 °C | |
Humidity (without condensation) | 0% – 90% (0 °C – 35 °C) 0% – 70% (35 °C – 55 °C) | |
Operating altitude | 2000 m |