Fluke Connect 789 ProcessMeter™ and Temperature Kit

SKU
FLUKE-789/T3000 FC
Manufacturer:
Fluke
Fluke

Key Features:

Fluke 789 Temperature Kit features:

  • Unique new wireless measurement logging capability
  • Temperature measurement from -200 °C to 1372 °C using the t3000 FC
  • 24 V Loop power supply
  • HART mode setting with loop power (adds 250 ohm resistor)
  • 100 % larger dual display
  • 1200 ohm drive capability on mA source
  • Enhanced backlight with two brightness settings
  • 0 % to 100 % mA Span Check buttons to toggle between 4 and 20 mA
  • Infrared I/O serial port compatible with
  • FlukeView® Forms Software Version 2.1
  • Externally accessible fuses for easy replacement

These 787 features are also included in the 789:

  • DMM designed to meet 1000 volt IEC 1010 CAT III standards
  • Precision 1000 V, 440 mA True-RMS digital multimeter
  • Frequency measurement to 20 kHz
  • Min/Max/Average/Hold/Relative modes
  • Diode test and continuity beeper
  • Simultaneous mA and % of scale readout
  • 20 mA dc current source/loop calibrator/ simulator
  • Manual Step (100 %, 25 %, Coarse, Fine) plus Auto Step and Auto Ramp
  • Externally accessible battery for easy battery changes
$1,788.99

Secured and trusted checkout with

The Fluke 789 ProcessMeter is the ultimate troubleshooting tool for electricians and instrumentation professionals, combining the functionality of a loop calibrator with the power of a digital multimeter. By equipping the 789 with a temperature measurement module and the wireless data logging capabilities of Fluke Connect® with ShareLive™ video call, process technicians can now do a lot more while carrying a lot less. And with its built-in, selectable 250 ohm HART® resistor, it eliminates the need to carry a separate resistor with you.

Use the included FC Connector with the Fluke 789 and get the full benefits of the Fluke Connect® app. Download it now and get started.

Fluke 789 ProcessMeter™ with Fluke Connect®

Specifications
Current measurementRange0-1 A AC or DC
Resolution1 mA
Accuracy0.2% + 2 LSD (DC)
Range0-30 mA
Resolution0.001 mA
Accuracy0.05% + 2 lSD
Current sourcingRange0-20 mA or 4-20 mA
Resolution0.05% of span
Drive capability24 V Compliance or 1200 Ω @ 20 mA
Frequencyto 19.999 kHz, 0.005% + 1 LSD
ContinuityBeeps for resistance < 100 Ω
Voltage measurementRange0-1000 V AC (true-rms) or DC
Resolution0.1 mV to 1.0 V
Accuracy0.1% Rdg + 1 LSD (VDC)
Resistance measurementto 40 MΩ, 0.2% + 1 LSD
Diode test2.0 V shoes diode voltage drop
Display current and % of spanYes
Auto Step, Auto RampYes

 

Environmental Specifications
Operating temperature-20 ºC to 55 ºC
Storage temperature-40 ºC to 60 ºC
Humidity (without condensation)95% up to 30 ºC
75% up to 40 ºC
45% up to 50 ºC
35% up to 55 ºC
Temperature coefficient0.05 x (specified accuracy) per ºC (for temperatures < 18 ºC or > 28 ºC)

 

Safety Specifications
Electrical safetyDesigned in accordance with IEC 1010-1, ANSI/ISA S82.01-1994 and CAN/CSA C22.2 No 1010.1-92
Overvoltage categoryIEC 1010-1 CAT III 1000 V
IEC 1010-1 CAT IV 600 V
Maximum voltage1000 V rms

 

Mechanical and General Specifications
Size50 x 100 x 203 mm (1.25" H x 3.41"W x 7.35" L)
Weight610 g (1.6 lbs)
Batteries4 AA alkaline batteries
Warranty3 years
Battery life140 hours typical (measurement), 10 hours typical (sourcing 20 mA)
Shock and vibrationRandom, 2 g, 5-500 Hz
1 meter drop test

 

Fluke t3000 FC Wireless K-Type Temperature Module

General Specifications
Range K-type-200 °C to 1372 °C
Resolution0.1 °C
Accuracy± [0.5 % + 0.5 °C] counts
Input terminalsK-type mini
LCD w/backlight3 ½ digits
Log rate/interval1 sec minimum/adjustable by PC
Battery type2 AA, NEDA 15 A, IEC LR6
Battery life400 hours
MemoryRecord up to 65,000 readings
RF communications2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructed: Up to 20 m
Obstructed, sheetrock wall: Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
Operating temperature-10 °C to +50 °C
Storage temperature-40 °C to +60 °C
Temperature coefficient0.01 % of reading +0.03 °C per °C
Temperature scaleITS-90
Operating humidity90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C
AltitudeOperating: 2,000 m
Storage: 12,000 m
EMCEN 61326-1:2006
Safety complianceIEC 61010-1, CAT I, 3rd edition Pollution Degree 2
CertificationsCSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) ratingIP42
Pollution Degree2
Size (HxWxD)16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in)
Weight.22 kg (8 oz)
WarrantyThree years

Note: Not compatible with Fluke CNX test tools

 

Includes:

  • • Fluke 789 ProcessMeter
  • • Fluke t3000 FC Wireless K-Type Temperature Module
  • • Fluke ir3000 FC Connector
  • • TL71 Premium Test Lead Set
  • • AC72 Alligator Clips
  • • Four (4) AA alkaline batteries (installed)
  • • Users' manual
  • • Quick reference guide
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account