With a simple, 3-button on-screen menu interface (in 6 languages) the Fluke 568 laser thermometer make even complex measurements easy. Quickly navigate advanced features to adjust emissivity, start data logging, or turn on and off alarms - with just a few pushes of a button.With a rugged, easy-to-use, ergonomic design, the Fluke 568 two-in-one contact and non contact thermometer can stand up to tough industrial, electrical, and mechanical environments. These tools go beyond other IR thermometers (or pyrometers), helping you work more efficiently in more applications.
Product Specifications | ||
Infrared temperature range | -40°C to 800°C (-40°F to 1472°F) | |
Infrared accuracy | < 0°C (32°F): ±(1.0°C (±2.0°F) + 0.1°/1°C or°F); | |
> 0°C (32°F): ±1% or ±1.0°C (±2.0°F), whichever is greater | ||
Display resolution | 0.1°C / 0.1°F | |
Infrared spectral response | 8 µm to 14 µm | |
Infrared response time | < 500 msec | |
Thermocouple Type-K input temperature range | -270°C to 1372°C (-454°F to 2501°F) | |
Thermocouple Type-K input accuracy | -270°C to -40°C | ±(1°C + 0.2°/1°C) (-454°F to -40°F: ±(2°F + 0.2°/1°F)) |
-40°C to 1372°C | ±1% or 1°C (-40°F to 2501°F: ±1% or 2°F), whichever is greater | |
D:S (distance to measurement spot size) | 50:1 | |
Laser sighting | Single-point laser < 1 mw output Class 2 (II) operation, 630 nm to 670 nm | |
Minimum spot size | 19 mm (0.75 in) | |
Emissivity adjustment | By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01 | |
Data storage with date/time stamp | 99 points | |
PC interface and cable | USB 2.0 with FlukeView® Forms software | |
Hi/Low alarms | Audible and two-color visual | |
Min/Max/Avg/Dif | Yes | |
Display | Dot matrix 98 x 96 pixels with function menus | |
Backlight | Two levels, normal and extra bright for darker environments | |
Trigger lock | Yes | |
Switchable Celsius and Fahrenheit | Yes | |
Power | 2 AA/LR6 Batteries and USB when used with a PC | |
Battery life | If used continuously | Laser and backlight on,12 hours; laser and backlight off, 100 hours |
Operating temperature | 0°C to 50°C (32°F to 122°F) | |
Storage temperature | -20°C to 60°C (-40°F to 140°F) | |
Bead thermocouple Type-K range | -40°C to 260°C (-40°F to 500°F) | |
Bead thermocouple Type-K accuracy | ±1.1°C (2.0°F) from 0°C to 260°C (32°F to 500°F), typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F) |
Included Accessories Shown Above